Background: This study investigates the integration of Artificial Intelligence (AI) in compensating the lack of time-of-flight (TOF) of the GE Omni Legend PET/CT, which utilizes BGO scintillation crystals.
Methods: The current study evaluates the image quality of the GE Omni Legend PET/CT using a NEMA IQ phantom. It investigates the impact on imaging performance of various deep learning precision levels (low, medium, high) across different data acquisition durations.
Positronium is abundantly produced within the molecular voids of a patient's body during positron emission tomography (PET). Its properties dynamically respond to the submolecular architecture of the tissue and the partial pressure of oxygen. Current PET systems record only two annihilation photons and cannot provide information about the positronium lifetime.
View Article and Find Full Text PDFBackground: This study evaluates the lesion contrast in a cost-effective long axial field of view (FOV) PET scanner, called the walk-through PET (WT-PET). The scanner consists of two flat detector panels covering the entire torso and head, scanning patients in an upright position for increased throughput. High-resolution, depth-of-interaction capable, monolithic detector technology is used to provide good spatial resolution and enable detection of smaller lesions.
View Article and Find Full Text PDFPolaritonic states, which are formed by resonances between a molecular excitation and the photonic mode of a cavity, have a number of useful properties that offer new routes to control molecular photochemistry using electric fields. To provide a theoretical description of how polaritonic states affect the real-time electron dynamics in molecules, a new method is described where the effects of strong light-molecule coupling are implemented using real-time electronic structure theory. The coupling between the molecular electronic states and the cavity is described by the Pauli-Fierz Hamiltonian, and transitions between polaritonic states are induced via an external time-dependent electric field using time-dependent configuration interaction (TDCI) theory, producing quantum electrodynamics TDCI (QED-TDCI).
View Article and Find Full Text PDFPurpose: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring.
Methods: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries. We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges.