Objectives: This study aims to compare the radiological, biomechanical, and histopathological results of microfracture treatment and osteochondral damage repair treatment with a new scaffold product produced by the three-dimensional (3D) bioprinting method containing gelatin-hyaluronic acid-alginate in rabbits with osteochondral damage.
Materials And Methods: A new 3D bioprinted scaffold consisting of gelatin, hyaluronic acid, and alginate designed by us was implanted into the osteochondral defect created in the femoral trochlea of 10 rabbits. By randomization, it was determined which side of 10 rabbits would be repaired with a 3D bioprinted scaffold, and microfracture treatment was applied to the other knees of the rabbits.
Purpose: The 2015 American Thyroid Association risk stratification system (2015-RSS) is used to assess the tumor recurrence rate and guide the initial treatment. At the current moment, patients with one or multiple intermediate risk factors (IRF) have the same treatment. This study was conducted to evaluate the impact of the number of IRF characteristics on tumor persistence or recurrence rates.
View Article and Find Full Text PDFIntroduction: The purpose of this study was to demonstrate that patients undergoing ACL reconstruction with quadrupled semitendinosus suspensory femoral and tibial fixation have comparable results in muscle strength and knee function to those undergoing ACL reconstruction with four-strand semitendinosus-gracilis suspensory femoral fixation and a bioabsorbable tibial interference screw fixation.
Materials And Methods: Between 2017 and 2019, 64 patients who were operated on by the same surgeon were included. Patients underwent ACL reconstruction technique with quadrupled semitendinosus suspensory femoral and tibial button fixation in Group 1, and patients underwent ACL reconstruction with coupled four-strand semitendinosus-gracilis suspensory femoral fixation and a bioabsorbable tibial interference screw in Group 2.
Aim: The purpose of this study was to design a sensor that could monitor the skin-cast contact surface pressure (SCCSP) of a limb under a cast and inform the user via a mobile application when the pressure increases.
Methods: In this experimental study, an infant sphygmomanometer cuff was initially placed on the forearm of 10 volunteers. A pressure sensor with a Bluetooth chip was then placed on the volar aspect of the forearm.
Objectives: This study aims to comparatively evaluate early to mid-term clinical results of case-matched patient groups of primary repairs with dynamic intraligamentary stabilization (DIS) or all-inside anterior cruciate ligament (ACL) reconstruction (ACLR) by an independent group.
Patients And Methods: Between March 2015 and September 2018, a total of 16 patients operated for ACL injuries with the repair technique were retrospectively identified. Cases were stratified by treatment: DIS technique versus all-inside ACLR and matched at a ratio of 1:2.