Publications by authors named "M Bidmead"

Aims: The CHHiP trial investigated the use of moderate hypofractionation for the treatment of localised prostate cancer using intensity-modulated radiotherapy (IMRT). A radiotherapy quality assurance programme was developed to assess compliance with treatment protocol and to audit treatment planning and dosimetry of IMRT. This paper considers the outcome and effectiveness of the programme.

View Article and Find Full Text PDF

A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours.

View Article and Find Full Text PDF

Purpose: To investigate the feasibility of dose escalation and hypofractionation of pelvic lymph node intensity modulated radiation therapy (PLN-IMRT) in prostate cancer (PCa).

Methods And Materials: In a phase 1/2 study, patients with advanced localized PCa were sequentially treated with 70 to 74 Gy to the prostate and dose-escalating PLN-IMRT at doses of 50 Gy (cohort 1), 55 Gy (cohort 2), and 60 Gy (cohort 3) in 35 to 37 fractions. Two hypofractionated cohorts received 60 Gy to the prostate and 47 Gy to PLN in 20 fractions over 4 weeks (cohort 4) and 5 weeks (cohort 5).

View Article and Find Full Text PDF

Background: Prostate cancer might have high radiation-fraction sensitivity that would give a therapeutic advantage to hypofractionated treatment. We present a pre-planned analysis of the efficacy and side-effects of a randomised trial comparing conventional and hypofractionated radiotherapy after 5 years follow-up.

Methods: CHHiP is a randomised, phase 3, non-inferiority trial that recruited men with localised prostate cancer (pT1b-T3aN0M0).

View Article and Find Full Text PDF

Purpose: To undertake the first multicentre fully 'end to end' dosimetry audit for HDR cervix brachytherapy, comparing planned and delivered dose distributions around clinical treatment applicators, with review of local procedures.

Materials And Methods: A film-dosimetry audit was performed at 46 centres, including imaging, applicator reconstruction, treatment planning and delivery. Film dose maps were calculated using triple-channel dosimetry and compared to RTDose data from treatment planning systems.

View Article and Find Full Text PDF