Despite the many potential applications of an accurate indoor positioning system (IPS), no universal, readily available system exists. Much of the IPS research to date has been based on the use of radio transmitters as positioning beacons. Visible light positioning (VLP) instead uses LED lights as beacons.
View Article and Find Full Text PDFAims: To identify the independent predictors of insulin sensitivity in Type 2 diabetes, and to establish whether isolated Type 2 diabetes (i.e. diabetes without overweight, dyslipidaemia and hypertension) is a condition of insulin resistance.
View Article and Find Full Text PDFObjective: The purpose of this study was to explore the relation between insulin resistance and plasma levels of soluble adhesion molecules and to examine the effects of acute hyperinsulinemia on these molecules in type 2 diabetic individuals.
Research Design And Methods: Intercellular adhesion molecule (ICAM)-1, vascular cell adhesion molecule (VCAM)-1, and E- and P-selectin plasma concentrations were measured in 36 nonobese type 2 diabetic patients without cardiovascular disease and in 7 healthy subjects. Insulin sensitivity was assessed by a 4-h euglycemic ( approximately 5 mmol/l)-hyperinsulinemic ( approximately 300 pmol/l) clamp performed in combination with [(3)H]3-D-glucose infusion.
The aim of this study was to ascertain whether the presence of hypertension conveys a more severe degree of insulin resistance in type 2 diabetes mellitus and, if so, which biochemical pathways are involved. We quantitated the rates of total glucose disposal, glycogen synthesis (GS), glycolysis, glucose oxidation, endogenous glucose production, and LOX in the basal state and during a 4-h euglycemic ( approximately 5 mM) hyperinsulinemic ( approximately 300 pM) clamp carried out in combination with a dual-tracer infusion ([(3)H]-3- and [(14)C]-U-D-glucose) and indirect calorimetry in 42 nonobese noninsulin-treated type 2 diabetic subjects (22 hypertensive and 20 normotensive) and 23 nonobese nondiabetic subjects (9 without and 14 with essential hypertension). Compared with normotensive controls, both groups of diabetic subjects were markedly insulin resistant.
View Article and Find Full Text PDFObjective: To evaluate whether the homeostasis model assessment (HOMA) is a reliable surrogate measure of in vivo insulin sensitivity in humans.
Research Design And Methods: In the present study, we compared insulin sensitivity as assessed by a 4-h euglycemic (approximately 5 mmol/l) hyperinsulinemic (approximately 300 pmol/l) clamp with HOMA in 115 subjects with various degrees of glucose tolerance and insulin sensitivity.
Results: We found a strong correlation between clamp-measured total glucose disposal and HOMA-estimated insulin sensitivity (r = -0.