Publications by authors named "M B Bramsen"

Objective/background: Heparin coating has recently been shown to reduce the risk of graft failure in arterial revascularisation, at least transiently. The aim of this study was to assess the cost-effectiveness of heparin coated versus standard polytetrafluoroethylene grafts for bypass surgery in peripheral artery disease from a long-term healthcare system perspective.

Methods: Cost-effectiveness evaluation was conducted alongside the Danish part of the Scandinavian Propaten trial in which 431 patients planned for femoro-femoral or femoro-popliteal bypass surgery were randomised to either type of graft and followed for 5 years.

View Article and Find Full Text PDF

Background: Cohort studies suggest superior long-term patency of luminal heparin-bonded polytetrafluoroethylene (Hb-PTFE) bypass grafts compared with standard PTFE grafts. The aim of this study was to compare the outcomes of Hb-PTFE grafts with those of standard PTFE grafts 5 years after a randomized trial.

Methods: Patients with intermittent claudication or critical limb ischaemia requiring femorofemoral or femoropopliteal bypass grafting were randomized in a clinical trial of Hb-PTFE versus standard PTFE in 11 Scandinavian centres between 2005 and 2009.

View Article and Find Full Text PDF

Objective: To investigate whether the relative size of intraluminal thrombus (ILT) in abdominal aortic aneurysms (AAAs) is associated with AAA growth.

Methods: This large observational study was based on a randomised population-based screening trial. Six hundred and fifteen AAAs were diagnosed in men aged 65-74 years.

View Article and Find Full Text PDF

Aim: The objective of the study was to evaluate the impact of the cardiac cycle on ultrasound measurements of abdominal aortic aneurysm (AAA) diameters.

Methods: In total, 603 AAAs detected by screening were investigated with respect to the maximal systolic and diastolic anterior-posterior aortic diameters during the cardiac cycle using recorded ultrasound video sequences.

Results: On average, the systolic AAA diameter was 41.

View Article and Find Full Text PDF

Objective: : To further develop and improve minimally invasive surgical procedures, dedicated appropriate surgical devices are mandatory. In this study, the safety and feasibility of implanting the novel Medtentia double helix mitral annuloplasty ring, which uses the key-ring principle to potentially allow faster and sutureless implantation, was assessed using both minimally invasive and conventional surgical techniques. Because of ethical concerns, a human compatible porcine experimental model of mitral valve surgery was used.

View Article and Find Full Text PDF