We present a new measurement of the 1S-3S two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of 9×10^{-13}. The proton charge radius deduced from this measurement, r_{p}=0.877(13) fm, is in very good agreement with the current CODATA-recommended value.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2016
We present a detailed characterization of two atomic clock interrogation systems based on two different cryogenic sapphire oscillators operated simultaneously. We use them as references for two accurate fountain clock frequency standards participating in international atomic time and operating both at the quantum projection noise frequency limit. The two fountain comparison down to a few 1016 over 28 days demonstrates the potential of a cryocooled oscillator to replace a He refilled cryogenic oscillator.
View Article and Find Full Text PDFWe use 6 yrs of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions, and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine transition frequency ratio. We find no signal consistent with a scalar dark matter candidate but provide improved constraints on the coupling of the putative scalar field to standard matter.
View Article and Find Full Text PDFLeveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer.
View Article and Find Full Text PDFProgress in realizing the SI second had multiple technological impacts and enabled further constraint of theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4 × 10(-16), have already been overtaken by atomic clocks referenced to an optical transition, which are both more stable and more accurate. Here we present an important step in the direction of a possible new definition of the second.
View Article and Find Full Text PDF