Secondhand exposure to cannabis smoke occurs in public outdoor locations due to outdoor smoking or leakage of indoor smoking. Very little is known regarding the actual levels of exposure. This study examined PM2.
View Article and Find Full Text PDFThe widespread legalization of recreational marijuana raises growing concerns about exposure to secondhand marijuana smoke. An important location for marijuana smoking is the home, but few measurements of air pollutant concentrations in the home are available for a marijuana joint fully smoked in one of its rooms. We used research grade calibrated real-time continuous PM air monitors in controlled 5-hour experiments to measure fine particle concentrations in the 9 rooms of a detached, two-story, 4-bedroom home with either a tobacco cigarette or a marijuana joint fully smoked in the home's living room.
View Article and Find Full Text PDFWe conducted 35 experiments for spatial measurement of marijuana aerosols in a current smoker's residential spaces. Fine particulate matter (PM) concentrations were measured every second at 1, 2, and 3 m horizontal distances from the smoker who performed prescribed 5-min smoking and vaping activities. In each experiment, five SidePak monitors measured PM concentrations at five different angles facing the front of the smoker, representing the worst-case exposures.
View Article and Find Full Text PDFObjective: Epidemiologic studies indicate that indoor air pollution is correlated with morbidity caused by allergic diseases. We evaluated the effectiveness of reducing the levels of indoor fine particulate matter <2.5 micrometer diameter (PM) in Fresno, California using air purifiers on health outcomes in children with asthma and/or allergic rhinitis.
View Article and Find Full Text PDFMost casinos owned by sovereign American Indian nations allow smoking, even in U.S. states such as California where state laws restrict workplace smoking.
View Article and Find Full Text PDFReal-time particle monitors are essential for accurately estimating exposure to fine particles indoors. However, many such monitors tend to be prohibitively expensive for some applications, such as a tenant or homeowner curious about the quality of the air in their home. A lower cost version (the Dylos Air Quality Monitor) has recently been introduced, but it requires appropriate calibration to reflect the mass concentration units required for exposure assessment.
View Article and Find Full Text PDFUnlabelled: As indoor smoking bans have become widely adopted, some U.S. communities are considering restricting smoking outdoors, creating a need for measurements of air pollution near smokers outdoors.
View Article and Find Full Text PDFFor an actively emitting source such as cooking or smoking, indoor measurements have shown a strong "proximity effect" within 1 m. The significant increase in both the magnitude and variation of concentration near a source is attributable to transient high peaks that occur sporadically-and these "microplumes" cause great uncertainty in estimating personal exposure. Recent field studies in naturally ventilated rooms show that close-proximity concentrations are approximately lognormally distributed.
View Article and Find Full Text PDFIndoor sources can greatly contribute to personal exposure to particulate matter less than 2.5 μm in diameter (PM2.5).
View Article and Find Full Text PDFBiomass combustion with traditional cookstoves causes substantial environmental and health harm. Nontraditional cookstove technologies can be efficacious in reducing this adverse impact, but they are adopted and used at puzzlingly low rates. This study analyzes the determinants of low demand for nontraditional cookstoves in rural Bangladesh by using both stated preference (from a nationally representative survey of rural women) and revealed preference (assessed by conducting a cluster-randomized trial of cookstove prices) approaches.
View Article and Find Full Text PDFPersonal exposure to air pollutants can be substantially higher in close proximity to an active source due to non-instantaneous mixing of emissions. The research presented in this paper quantifies this proximity effect for a non-buoyant source in 2 naturally ventilated homes in Northern California (CA), assessing its spatial and temporal variation and the influence of factors such as ventilation rate on its magnitude. To quantify how proximity to residential sources of indoor air pollutants affects human exposure, we performed 16 separate monitoring experiments in the living rooms of two detached single-family homes.
View Article and Find Full Text PDFThe amount of light scattered by airborne particles inside an aerosol photometer will vary not only with the mass concentration, but also with particle properties such as size, shape, and composition. This study conducted controlled experiments to compare the measurements of a real-time photometer, the SidePak AM510 monitor (SidePak), with gravimetric mass. PM sources tested were outdoor aerosols, and four indoor combustion sources: cigarettes, incense, wood chips, and toasting bread.
View Article and Find Full Text PDFFor modeling exposure close to an indoor air pollution source, an isotropic turbulent diffusion coefficient is used to represent the average spread of emissions. However, its magnitude indoors has been difficult to assess experimentally due to limitations in the number of monitors available. We used 30-37 real-time monitors to simultaneously measure CO at different angles and distances from a continuous indoor point source.
View Article and Find Full Text PDFSmoking bans often exempt casinos, exposing occupants to fine particles (PM(2.5)) from secondhand smoke. We quantified the relative contributions to PM(2.
View Article and Find Full Text PDFElectrochemical sensors are commonly used to measure concentrations of gaseous air pollutants in real time, especially for personal exposure investigations. The monitors are small, portable, and have suitable response times for estimating time-averaged concentrations. However, for transient exposures to air pollutants lasting only seconds to minutes, a non-instantaneous time response can cause measured values to diverge from actual input concentrations, especially when the pollutant fluctuations are pronounced and rapid.
View Article and Find Full Text PDFDespite California's 1994 statewide smoking ban, exposure to secondhand smoke (SHS) continues in California's Indian casinos. Few data are available on exposure to airborne fine particles (PM₂.₅) in casinos, especially on a statewide basis.
View Article and Find Full Text PDFIndoor and outdoor airborne particle mass, protein, endotoxin and (1 --> 3)-beta-D-glucan in three size fractions (PM2.5, PM10, and TSP) were measured in ten single-family homes, along with quantifying household activities in the sampling room. Correlations between human activity levels and elevations in the indoor concentrations of particles and biomarkers were evaluated using four approaches for distinguishing activity levels: diurnal differences, the number of occupants, self-estimated occupancy, and activity strength.
View Article and Find Full Text PDFThe rate at which motor vehicle exhaust undergoes dilution with ambient air will greatly affect the size distribution characteristics of the particulate emissions. Wind tunnel experiments were conducted to investigate the impacts of vehicle shape, tailpipe orientation, and exhaust exit velocity on the dilution profiles under steady driving conditions for three model vehicles: a light-duty truck, a passenger car, and a heavy-duty tractor head. A three dimensional array of 60 sensors provided simultaneous measurements of dilution ratios for the emissions in the near- and far-wake regions downstream of the vehicle.
View Article and Find Full Text PDFThe particle and gaseous pollutants in vehicle exhaust emissions undergo rapid dilution with ambient air after exiting the tailpipe. The rate and extent of this dilution can greatly affect both the size evolution of primary exhaust particles and the potential for formation of ultrafine particles. Dilution ratios were measured inside of a wind tunnel in the region immediately downstream of the tailpipe using model vehicles (approximately one-fifth to one-seventh scale models) representing a light-duty truck, a passenger car, and a heavy-duty tractor head (without the trailer).
View Article and Find Full Text PDFChronic obstructive pulmonary diseases (COPD) may increase air pollution-related mortality. The relationship of immune mechanisms to mortality caused by fine particulates in healthy and COPD populations is incompletely understood. The objective of this study was to determine whether fine particulates from a single biomass fuel alter stress and inflammation biomarkers in people with COPD.
View Article and Find Full Text PDFInfect Control Hosp Epidemiol
May 2008
Air samples taken in a hospital undergoing construction and analyzed with a quantitative polymerase chain reaction (qPCR) assay for the Aspergillus genus did not show elevated concentrations of Aspergillus or particulate matter with a diameter of 5 microm or less in patient areas. Air samples from the construction zone indicated the containment system, which used polyethylene film barrier and negative pressure, was effective.
View Article and Find Full Text PDFAspergillus is a genus of mold that has strong indoor sources, including several species capable of acting as opportunistic pathogens. Previous studies suggest that Aspergillus could serve as an indicator for abnormal mold growth or moisture, making it an important genus for environmental monitoring. Here, a quantitative polymerase chain reaction (qPCR, or real-time PCR) assay is presented for Aspergillus.
View Article and Find Full Text PDFAs part of the Southeastern Aerosol and Visibility Study (SEAVS), water-soluble organic species (WSOS) in fine aerosols collected from July 15 to August 25, 1995, at the Great Smoky Mountain National Park, Tennessee (USA), were chemically classified into seven groups, with concentrations ranging from around 1 to >200 ng/m3. Dicarboxylic acids represented the dominant identified compound class, and succinic acid was the most abundant dicarboxylic acid. The trends in data suggest that most WSOS collected in the SEAVS samples were mainly generated from secondary photochemical reactions, especially during the first (cleaner) half of the sampling campaign.
View Article and Find Full Text PDFJ Air Waste Manag Assoc
September 2004
This study compares an indoor-outdoor air-exchange mass balance model (IO model) with a chemical mass balance (CMB) model. The models were used to determine the contribution of outdoor sources and indoor resuspension activities to indoor particulate matter (PM) concentrations. Simultaneous indoor and outdoor measurements of PM concentration, chemical composition, and air-exchange rate were made for five consecutive days at a single-family residence using particle counters, nephelometers, and filter samples of integrated PM with an aerodynamic diameter of less than or equal to 2.
View Article and Find Full Text PDFJ Expo Anal Environ Epidemiol
July 2004
Continuous laser particle counters collocated with time-integrated filter samplers were used to measure personal, indoor, and outdoor particulate matter (PM) concentrations for a variety of prescribed human activities during a 5-day experimental period in a home in Redwood City, CA, USA. The mean daytime personal exposures to PM(2.5) and PM(5) during prescribed activities were 6 and 17 times, respectively, as high as the pre-activity indoor background concentration.