The effectiveness of commercially available interventions for reducing workers' perchloroethylene exposures in three small dry-cleaning shops was evaluated. Depending upon machine configuration, the intervention consisted of the addition of either a refrigerated condenser or a closed-loop carbon adsorber to the existing dry-cleaning machine. These relatively inexpensive (less than $5000) engineering controls were designed to reduce perchloroethylene emissions when dry-cleaning machine doors were opened for loading or unloading.
View Article and Find Full Text PDFReal-time monitoring was used to evaluate the ability of engineering control devices retrofitted on two existing dry-cleaning machines to reduce worker exposures to perchloroethylene. In one dry-cleaning shop, a refrigerated condenser was installed on a machine that had a water-cooled condenser to reduce the air temperature, improve vapor recovery, and lower exposures. In a second shop, a carbon adsorber was retrofitted on a machine to adsorb residual perchloroethylene not collected by the existing refrigerated condenser to improve vapor recovery and reduce exposures.
View Article and Find Full Text PDF