Publications by authors named "Lyn Bowman"

Purpose Of Review: This review updates readers on recent developments in the assessment of cortical bone fragility in vivo. The review explains the clinical need that motivated the development of Cortical Bone Mechanics Technology™ (CBMT) as a scientific instrument, its unique capabilities, and its necessary further development as a medical device.

Recent Findings: Clinical experience with dual-energy X-ray absorptiometry has led to calls for new clinical methods for assessing bone health.

View Article and Find Full Text PDF

Cortical Bone Mechanics Technology™ (CBMT) comprises certain improvements over a previous method known as Mechanical Response Tissue Analysis (MRTA). Both methods are dynamic 3-point bending tests intended for measuring the mechanical properties of cortical bone in living people. MRTA presented a theoretical potential for direct measurement of skeletal fragility, but it had acquired a reputation for error and fallen into disuse.

View Article and Find Full Text PDF

Background: High error rates in the prediction of fragility fractures by bone mineral density have motivated searches for better clinical indicators of bone strength, and the high incidence of non-hip, non-spine fractures has raised interest in cortical bone. The aim of this study was to assess the accuracy of Cortical Bone Mechanics Technology™. CBMT is a new non-invasive 3-point bending technique for measuring the mechanical properties of cortical bone in the ulnas of living humans.

View Article and Find Full Text PDF

We read with great interest the recent review by de Bakker et al that summarized the state of several existing and emerging technologies for estimating bone strength and fracture risk in vivo. Much of their review focused on how well the measurements of selected technologies predicted experimental measurements of bone strength by ex vivo quasistatic mechanical testing (QMT) and on how well they tracked changes in mechanical properties of bone. The authors noted that the association of many common skeletal health measurements (e.

View Article and Find Full Text PDF

Osteoporosis is characterized by reduced bone strength, but no FDA-approved medical device measures bone strength. Bone strength is strongly associated with bone stiffness, but no FDA-approved medical device measures bone stiffness either. Mechanical Response Tissue Analysis (MRTA) is a non-significant risk, non-invasive, radiation-free, vibration analysis technique for making immediate, direct functional measurements of the bending stiffness of long bones in humans in vivo.

View Article and Find Full Text PDF