Introduction: Treatment of ischemic stroke has expanded beyond the 6-hour window, but identification of eligible patients requires advanced imaging, which is often unavailable. This study aimed to validate a prediction model using the NIHSS score (a measure of stroke severity) to estimate hypoperfusion volume and determine eligibility for DEFUSE 3 treatment criteria.
Materials And Methods: Data from ischemic stroke patients with less than 24 hours' evolution were analyzed.
Background: The use of endovascular procedures is becoming increasingly popular across multiple clinical domains. These procedures are generally performed under image guidance using an interventional c-arm x-ray system. Radiation exposure to both patients and interventional staff due to use of fluoroscopy is a health and occupational concern, but modifications to the interventional workflow to address radiation may come at the cost of procedure time or quality.
View Article and Find Full Text PDFBackground: Multiple studies and meta-analyses have described the technical and clinical outcomes in large cohorts of aneurysm patients treated with flow diverters (FDs). Variations in evaluation methodology complicate making comparisons among studies, hinder understanding of the device behavior, and pose an obstacle in the assessment of further advances in FD therapy.
Methods: A multidisciplinary panel of neurointerventionalists, imaging experts, and neuroradiologists convened with the goal of establishing consensus recommendations for the standardization of image analyses in FD studies.
Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making.
View Article and Find Full Text PDFThe potential clinical usefulness of electron density (ED) imaging, that can be directly estimated using dual-layer spectral computed tomography (CT), has been poorly investigated. We explored whether ED imaging might improve thrombus identification compared to conventional imaging in vitro. We evaluated mechanical thrombectomy material obtained from patients with acute ischemic stroke (AIS) treated in a tertiary level stroke center and immediately fixed in 10% neutral buffered formalin and stored in polystyrene test tubes.
View Article and Find Full Text PDFBackground: The PEDESTRIAN registry demonstrated high rates of complete long-term occlusion and good clinical outcomes among patients with intracranial aneurysms treated with the pipeline embolization device. The pipeline flex embolization device with shield technology was introduced to minimize thromboembolic complications. In this study, we investigated the safety and effectiveness of pipeline embolization device with shield technology among all patients treated for intracranial aneurysms at our center.
View Article and Find Full Text PDFBackground: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms.
View Article and Find Full Text PDFBackground: The aim of this study was to evaluate the overall rates of braid changes associated with flow diverter (FD) treatment for intracranial aneurysms (IAs). Additionally, we sought to provide an overview of the currently reported definitions related to these complications.
Methods: A systematic search was conducted from the inception of relevant literature up to April 2023, encompassing six databases.
Purpose: Spectral computed tomography (CT) enables improved tissue characterization, although virtually all research has focused on contrast-enhanced examinations. We hypothesized that changes in myocardial tissue related to acute myocardial infarction (AMI) might potentially be identified without the need for contrast administration using electron density (ED) imaging.
Patients And Methods: This retrospective observational study involved a small series (n = 15) of patients admitted to our institution with a first AMI without signs of hemodynamic instability and identification of a culprit vessel with invasive coronary angiography during the same admission, who also underwent a noncontrast, low-dose chest CT using a dual-layer spectral CT scanner.
Introduction: The start of the COVID-19 pandemic forced the implementation of changes in the emergency services care system. Concomitantly, at our institution, we implemented the artificial intelligence (AI) software, RAPID.AI, for image analysis in ischemic stroke (IS).
View Article and Find Full Text PDFObjective: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment.
View Article and Find Full Text PDFBackground: Traditional endovascular treatments of giant intracranial aneurysms are associated with high rates of complications and retreatment. Our objective was to examine the safety and long-term efficacy of the Pipeline Embolization Device for treatment of these aneurysms.
Methods: This retrospective study using the IntrePED database included all patients with giant intracranial aneurysms treated with the Pipeline device between July 2008 and February 2013.
Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status.
View Article and Find Full Text PDFBackground: Embolization of the middle meningeal artery (MMA) is a promising minimally invasive technique that is gaining traction in the treatment of chronic subdural hematoma. Unfortunately, the human meninges and associated arteries are significantly larger than those of conventional laboratory animals, making the development of a clinically relevant animal model for testing of embolization agents elusive.
Objective: To introduce the posterior intercostal artery (PIA) model in swine and provide anatomical, angiographic, histological, and procedural data to validate its relevance in modeling the human MMA.
Background: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status.
Methods: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device.
Introduction: Bifurcation aneurysms represent an ongoing endovascular challenge with a variety of techniques and devices designed to address them. We present our multicenter series of the pCONUS2 and pCONUS2 HPC devices when treating bifurcation aneurysms.
Methods: We performed a retrospective review of our prospectively maintained databases at 3 tertiary neurointerventional centers to identify all patients who underwent coil embolization with the pCONUS2 or pCONUS2 HPC device between February 2015 and August 2021.