Publications by authors named "Lutter G"

Background: Heavy calcifications in severe aortic stenosis (AS) pose a major challenge in patients undergoing transcatheter aortic valve replacement (TAVR). Only a few studies have addressed the performance of different transcatheter heart valves (THV) in this subgroup of patients.

Objectives: We aimed to investigate the outcomes of the self-expanding Medtronic CoreValve Evolut valve frame and the balloon-expandable Edwards SAPIEN-3/3 Ultra THV in this challenging patient population.

View Article and Find Full Text PDF

Targeted gene delivery to vascular smooth muscle cells (VSMCs) could prevent or improve a variety of diseases affecting the vasculature and particularly the aorta. Thus, we aimed to develop a delivery vector that efficiently targets VSMCs. We selected engineered adeno-associated virus (AAV) capsids from a random AAV capsid library and tested the top enriched motifs in parallel screening through individual barcoding.

View Article and Find Full Text PDF
Article Synopsis
  • A search for dark matter candidates in the mass range of 65 to 1021 keV was conducted using data from the GERDA experiment, focusing on energy depositions without detecting any significant signals above background noise.
  • The study established stringent exclusion limits on dark photon and axion-like particle interactions with electrons, with specific constraints noted at a 150 keV mass level.
  • Additional investigations into the decay rates of nucleons and electrons yielded lower lifetime limits for neutron, proton, and electron decay events at a 90% confidence interval.
View Article and Find Full Text PDF

Background: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms.

Objectives: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology.

Methods: TAV explants were obtained from the EXPLANT THV registry and clinical institutions.

View Article and Find Full Text PDF

Introduction: Transcatheter mitral valve replacement (TMVR) is a valuable treatment option in patients with severe mitral regurgitation. Prior transapical transcatheter aortic valve replacement (TA-TAVR) may complicate the procedure and is therefore considered a relative contraindication. In this case report, the authors describe the successful TMVR as a tertiary cardiac surgery and transapical redo procedure.

View Article and Find Full Text PDF

Objectives: To investigate the change in severity of mitral regurgitation (MR) after transcatheter aortic valve replacement (TAVR) and its effect on 5-year mortality.

Background: There is inconsistency in literature on pre-existing MR influencing long-term survival in patients who undergo TAVR.

Methods: Patients who underwent TAVR at the University Hospital Schleswig-Holstein (USKH) Campus Kiel between March 2009 and February 2018 have been enrolled.

View Article and Find Full Text PDF

One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity.

View Article and Find Full Text PDF

. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors.

View Article and Find Full Text PDF

Background: TAVI indications expand not only to low-risk patients but also to patients with a more complex anatomy and comorbidities. Transfemoral retrograde access is recognized as the first preferred approach according to the current guidelines. However, this approach is not suitable in up to 10-15% of patients, for whom an alternative non-femoral access route is required.

View Article and Find Full Text PDF

Rupture or dissection of thoracic aortic aneurysms is still the leading cause of death for patients diagnosed with Marfan syndrome. Inflammation and matrix digestion regulated by matrix metalloproteases (MMPs) play a major role in the pathological remodeling of the aortic media. Regnase-1 is an endoribonuclease shown to cleave the mRNA of proinflammatory cytokines, such as interleukin-6.

View Article and Find Full Text PDF
Article Synopsis
  • Transcatheter pulmonary valve replacement is a developing minimally-invasive treatment for right ventricular outflow tract dysfunction, addressing the limitations of current heart valve options.
  • Researchers created 3D tissue-engineered tri-leaflet valved stent grafts using biodegradable PCL nanofiber scaffolds seeded with different types of stem cells.
  • The study observed that over 90% of the heart valve leaflets were covered with cells after three weeks, demonstrating the potential for these engineered valves to improve future treatments.
View Article and Find Full Text PDF

The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides.

View Article and Find Full Text PDF

We present the measurement of the two-neutrino double-β decay rate of ^{76}Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg yr, the half-life of the process has been determined: T_{1/2}^{2ν}=(2.

View Article and Find Full Text PDF

: Unilateral pulmonary edema (UPE) is a potential complication after mitral valve surgery (MVS), and its cause is not yet fully understood. Definitions are inconsistent, and previous studies have reported wide variance in the incidence of UPE. This research aims at the evaluation of the Radiographic Assessment of Lung Edema (RALE) score concerning assessment of UPE after MVS in order to provide an accurate and consistent definition of this pathology.

View Article and Find Full Text PDF

We search for tri-nucleon decays of Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to Cu, Zn, and Ga nuclei, respectively.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is now a well-established therapeutic option in an elderly high-risk patient cohort with aortic valve disease. Although most commonly performed via a transfemoral route, alternative approaches for TAVI are constantly being improved. Instead of the classical mini-sternotomy, it is possible to achieve a transaortic access via a right anterior mini-thoracotomy in the second intercostal space.

View Article and Find Full Text PDF

Background: When a balloon-expandable transcatheter heart valve (THV) is chosen to treat a failed balloon-expandable THV, there is a risk of underexpansion with a potential impact on performance.

Aims: We aimed to assess the impact of pre- and post-dilatation on the expansion of balloon-expandable THVs after redo-transcatheter aortic valve implantation (TAVI).

Methods: Redo-TAVI was performed on the bench with a 23 mm SAPIEN 3 (S3) implanted within a 23 mm SAPIEN XT (SXT) or a 23 mm S3, both of which served as the "failed" THVs.

View Article and Find Full Text PDF

Background:  Composite T-grafts between left internal mammary artery (LIMA) and radial artery (RA) are a common concept in complete arterial myocardial revascularization. The aim of the present study was to investigate whether the use of the great saphenous vein (SV) instead of RA leads to comparably good results in terms of outcome in this context.

Methods:  Patients who underwent myocardial revascularization with a T-graft using RA or a segment of SV to the right coronary artery or circumflex artery between the beginning of 2014 and the end of 2019 at the Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel were included.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) can either be conducted as an elective (scheduled in advance) or a non-elective procedure performed during an unplanned hospital admission. The objective of this study was to compare the outcomes of elective and non-elective TAVI patients.

Methods: This single-centre study included 512 patients undergoing transfemoral TAVI between October 2018 and December 2020; 378 (73.

View Article and Find Full Text PDF

Background: There are limited data on the effect of bioprosthetic valve remodeling (BVR) on transcatheter heart valve (THV) expansion and function following valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) in a nonfracturable surgical heart valve (SHV).

Objectives: This study sought to assess the impact of BVR of nonfracturable SHVs on THVs after VIV implantation.

Methods: VIV TAVR was performed using 23-mm SAPIEN3 (S3, Edwards Lifesciences) or 23/26-mm Evolut Pro (Medtronic) THVs implanted in 21/23-mm Trifecta (Abbott Structural Heart) and 21/23-mm Hancock (Medtronic) SHVs with BVR performed with a noncompliant TRUE balloon (Bard Peripheral Vascular Inc).

View Article and Find Full Text PDF

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the Gerda experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the Gerda liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

View Article and Find Full Text PDF

Objective: Outcomes after surgical aortic root replacement using different valved conduits are rarely reported. The present study shows the experience of a single center with the use of the partially biological LABCOR (LC) conduit and the fully biological BioIntegral (BI) conduit. Special attention was paid to preoperative endocarditis.

View Article and Find Full Text PDF

The L6 chondritic meteorite, HaH-346, fell in Libya. However, neither the exact date of the fall nor the exact size of the original meteoroid or asteroid is known. A specimen of the meteorite, weighing 488 g, was measured using ultra low-background gamma-ray spectrometry in the 225 m deep underground facility HADES.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session1k82v42detge8k3ckgov36074987ma1q): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once