Publications by authors named "Lukasz Lapaj"

Revision total hip arthroplasty using custom monoflange acetabular components (CMACs) in cases of severe bone loss is becoming an increasingly preferred alternative to traditional implants, which may not provide stable fixation in such cases. However, this procedure also carries a higher risk of infection and implant loosening. This case report discusses a 67-year-old female patient who presented with old acetabular component loosening and significant pelvic bone loss.

View Article and Find Full Text PDF

: Stem revisions in revision total hip arthroplasty (THA) with proximal bone stock loss may be dealt with utilizing modular, uncemented conical stems. During stem extraction, surgeons may resort to extended trochanteric osteotomy (ETO). However, ETO is associated with extensive blood loss and infections.

View Article and Find Full Text PDF

: The objective of this retrospective study was to investigate the association between acetabulum fractures; the mechanism of injury; and variables such as BMI, duration of hospital stay, blood loss, and surgery time. By exploring these factors, we aim to enhance our understanding of them and their impact on the healing process and the subsequent management of pelvic fractures. : This study included 67 of 136 consecutive patients who were admitted for pelvic ring fracture surgery between 2017 and 2022.

View Article and Find Full Text PDF

Purpose: Polyaxial locking plates rely on the alignment between the thread-to-thread connections of the screw head and the plate hole. These implants have provided substantial support for surgeons. In particular, extended screw positioning have proven to be beneficial in the fixation of challenging fractures.

View Article and Find Full Text PDF

Polyaxial locking plates rely on a specific thread-to-thread interface of the screw head and the plate hole. The objective of this study was to evaluate the mechanical performance of single screw interfaces when inserted off-axis and to establish correlations between those parameters and the engagement of the screw head and the plate hole thread. Three polyaxial locking screw systems were inserted into the corresponding plates at various angles (0°, 5°, 10°, and 15° off-axis).

View Article and Find Full Text PDF

Objective: the aim of this study was to document the occurrence of THA after acetabulum surgery and examine the factors that predict its occurrence.

Methods: This study included 77 consecutive patients who were admitted for acetabulum fracture surgery between 2012 and 2019. The inclusion criteria were acetabular fractures and indications for operative management.

View Article and Find Full Text PDF

Purpose: Formerly poor bone stock and periprosthetic fractures used to jeopardize monaxial constructs. Polyaxial locking screws have substantially supported those particular fixation constructs. However, those systems rely on complex alignment between the screw head and the plate hole.

View Article and Find Full Text PDF

This retrieval study included 43 Biolox delta explants (18 CoC, 25 CoP). Implants were examined macroscopically, whereby damage was evaluated using a semi quantitative scoring system. Confocal microscopy was used to examine wear related damage patterns of the articulating surfaces.

View Article and Find Full Text PDF

Routine resection of the infrapatellar fat pad (IFP) during total knee arthroplasty (TKA) is controversial, as it may result in shortening of the patellar tendon (PT) and anterior knee pain. This prospective study examined whether IFP excision during TKA affects joint function, anterior knee pain, PT dimensions and sonographic structure. A total of 65 consecutive patients undergoing TKA for osteoarthritis were randomized into two groups: IFP was resected in one and retained in the other.

View Article and Find Full Text PDF

Complete loss of the meniscus inevitably leads to knee joint degeneration. Smoking is an important factor predicting poor outcome in orthopedics; however, data about its role in meniscus surgery are inconclusive. Smoking could be an important negative factor in isolated meniscus repair.

View Article and Find Full Text PDF

Percutaneous acute Achilles tendon rupture suturing has become a leading treatment option in recent years. A common complication after this mini-invasive procedure is sural nerve injury, which can reduce the patients' satisfaction and final outcomes. High-resolution ultrasound is a reliable method for localizing the sural nerve, and it can be performed intra-operatively; however, the long-term results are yet unknown.

View Article and Find Full Text PDF

Aim: The purpose of this study was to investigate whether there is an association between smoking, the extent of the degeneration process in the biceps tendinopathy, including cells and extracellular matrix (ECM) alterations, and long-term surgical results.

Methods: This study comprised 40 consecutive patients admitted for shoulder arthroscopy due to symptomatic biceps tendinopathy and classified into three groups based on smoking status: active smokers, former smokers, and non-smokers. According to the classical Bonar score criteria, the histopathologic evaluation of the harvested intra-articular portion of the tendon was done.

View Article and Find Full Text PDF

The purpose of this study was to investigate the association of smoking and functional outcomes after arthroscopic treatment of complex shoulder injuries: rotator cuff tears (RCTs) with biceps tendon (LHBT) tears. This retrospective case-control study has been conducted on a cohort of patients who underwent shoulder arthroscopy between 2015 and 2017 due to complex injury treatment. The outcomes were assessed using the American Shoulder and Elbow Surgeons Score (ASES), the University of California at Los Angeles (UCLA) Shoulder Score, need for non-steroid anti-inflammatory drugs (NSAIDs) consumption and the visual analog scale (VAS).

View Article and Find Full Text PDF

The study aimed to evaluate the results after arthroscopic tenodesis and tenotomy of the biceps tendon (LHBT), coupled in tenotomy modality with a personalized postoperative rehabilitation protocol. The study included patients who underwent arthroscopic biceps tenotomy or tenodesis due to chronic biceps tendinopathy. Postoperatively, a standard rehabilitation program was prescribed to the tenodesis group and personalized was introduced in the tenotomy group, respectively.

View Article and Find Full Text PDF

Introduction: Titanium nitride (TiN) coatings are used in joint arthroplasty to minimize wear and reduce the allergenic potential of metal implants, yet little is known about their performance in knee arthroplasty. This retrieval study examined TiN coated knee replacements to verify in vivo wear and degradation of the coating.

Materials And Methods: This study included total and unicompartmental mobile bearing knee replacements retrieved from five patients (eight components) after 13-21 months due to aseptic loosening or infection.

View Article and Find Full Text PDF

Background: Breakage of joint arthroplasty components are rare, yet during an implant retrieval program we found several cases.

Objective: In this study we examined the components to determine the causes and mechanisms of breakage of these implants.

Methods: From our collection of 849 retrievals we selected 682 cases with metal parts (503 hip, 79 knee arthroplasties) and identified fractured components: seven hip resurfacing implants, five total hip replacement stems, one monopolar femoral head, and one modular revision femoral stem from.

View Article and Find Full Text PDF

Pigmented villonodular synovitis (PVNS) as well as tenosynovial giant cell tumor (TGCT) are both diagnosed and described in two forms, namely a localized and diffuse type. They form a diverse group of proliferative lesions in articular synovium and tendon sheaths. The inconsistent terminology impedes communication between patients, orthopedic surgeons, radiologists and pathologists, leading to misunderstandings and delaying treatment.

View Article and Find Full Text PDF
Article Synopsis
  • Tendinopathy of the long head of the biceps tendon is a complex issue with unclear causes and primarily degenerative characteristics, as tendons have limited ability to heal.
  • A study involving 35 patients who underwent arthroscopic procedures showed degeneration in all samples taken from the long head of the biceps tendon.
  • Findings suggest that while inflammation plays a key role early on in the condition, it eventually becomes secondary to the degeneration process in the tendon, with inflammation possibly indicating re-injury or healing attempts.
View Article and Find Full Text PDF

Background and purpose - Severe backside wear, observed in older generations of total knee replacements (TKRs), led to redesign of locking mechanisms to reduce micromotions between tibial tray and inlay. Since little is known about whether this effectively reduces backside wear in modern designs, we examined backside damage in retrievals of various contemporary fixed-bearing TKRs. Patients and methods - A consecutive series of 102 inlays with a peripheral (Stryker Triathlon, Stryker Scorpio, DePuy PFC Sigma, Aesculap Search Evolution) or dovetail locking mechanism (Zimmer NexGen, Smith and Nephew Genesis II) was examined.

View Article and Find Full Text PDF

Background: Total knee arthroplasty in joints with valgus or varus deformity is technically demanding. Careful soft tissue balance as well as restitution of anatomical knee axis has a profound effect on postoperative function of the joint, however little is known about differences in subjective stability following surgery between preoperative valgus and varus knees.

Material And Methods: Studied group consisted of 60 patients who underwent total condylar knee arthroplasty with one type of implant (Stryker Triathlon).

View Article and Find Full Text PDF

Data regarding in vivo performance of titanium nitride (TiN) coated prosthetic femoral heads is scarce, and available studies of older generations of implants demonstrated coating wear in vivo. That is why we conducted a retrieval analysis of 11 femoral heads (articulating in vivo for 1-56 months) with TiN film formed using physical vapor deposition (PVD), to verify if coating failure is a problem in contemporary implants. Retrieved implants were examined using scanning electron microscope, coating roughness was evaluated with a contact profilometer and adhesion was tested using a Rockwell HRC test according to VDI 3824 guideline.

View Article and Find Full Text PDF

Background: The Zweymüller stem is well-known in Europe and widely used for total hip replacement since 1980. Few authors have noted the presence of increased bone density below the tip of the stem; however, the underlying mechanism is still unknown. The aim of this study was to reveal factors influencing bone remodeling around the tip of the Zweymüller stem.

View Article and Find Full Text PDF

This article presents examination of a failed total hip replacement with surface engineered metal-on-metal (MoM) articulation. The implant was coated with a thin TiNbN film (Physical Vapor Deposition), and at retrieval 53 months after implantation the coating was abraded on weight-bearing part of the head and acetabular component. Scanning electron microscopy of bearing surfaces demonstrated multifocal crack formation, delamination of small film fragments, and formation of aggregates containing nanometer sized wear debris.

View Article and Find Full Text PDF

We report a case of a female patient using a McKee-Farrar prosthesis for 30 years, until revision surgery for aseptic loosening. Electron microscopy analysis of bearing surface of the retrieved implant was performed, and the results were presented in comparison with previously published papers.

View Article and Find Full Text PDF