In many countries, there is an interest in determining the location of the women with the highest breast density. This investigation is important for optimize screening for breast cancer for women with dense breasts as other imaging modalities since 2D mammography is not very efficient on this type of breast. The objective of this study was to evaluate the variations in breast density in Brazilian women of different regions of Brazil.
View Article and Find Full Text PDFThermoluminescence dosimeters containing boron, such as magnesium tetraborate (MgBO), are of interest because of their very high sensitivity, near tissue-equivalent absorption coefficients, low cost, easy handling, and very large linearity range for absorbed dose. Another important parameter that should be considered when working with thermoluminescent dosimeter (TLD) is the mass energy absorption coefficient (μ/ρ), which is a close approximation to the energy available for production of chemical, biological and other effects associated with exposure to ionizing radiation, therefore important in estimating dose in medical and health physics. In this study the mass energy absorption coefficients and energy responses of undoped and some doped magnesium tetraborates were calculated by Monte Carlo N-particle transport code for a range of photon energies between 20 keV and 20 MeV.
View Article and Find Full Text PDFJ Environ Sci Health A Tox Hazard Subst Environ Eng
July 2016
The effect of the initial concentration of linear alkylbenzene sulfonate (LAS) on specific methanogenic activity (SMA) was investigated in this work. Six anaerobic flasks reactors with 1 L of total volume were inoculated with anaerobic sludge (2 g VSS L(-1)). The reactors were assayed for 42 days, and fed with volatile fatty acids, nutrients, and LAS.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2010
With the increased incidence of cancer and a similarly increased number of surgeries for insertion of silicone breast implants, it is necessary to assess the effect of such material within the breast tissue, particularly in mammography, because of the reduction in the power of breast cancer diagnosis. In this work, we introduce a breast phantom with silicone implants in order to evaluate the influence of the implant on the visibility of the main mammographic findings: fibers, microcalcifications and tumor masses. In this proposed phantom, the breast tissue was simulated using gel paraffin.
View Article and Find Full Text PDF