Cardiac stimulation therapy has evolved significantly over the past 30 years. Currently, cardiac implantable electronic devices (CIED) are the mainstream therapy for many potentially lethal heart conditions, such as advanced atrioventricular block or sustained ventricular tachycardia or fibrillation. Despite sometimes being lifesaving, the implant is surgical and therefore carries all the inevitable intrinsic risks.
View Article and Find Full Text PDFThis is a report of the first Brazilian experience with the Perceval sutureless aortic prosthesis in two patients with severe aortic stenosis. Transesophageal echocardiography was used during the procedure. The aortotomy was performed 1 cm above the sinotubular junction, followed by leaflets removal and decalcification.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
November 2010
Endovascular procedures are increasing in number for the treatment of thoracic aortic diseases (TAD). Retrograde approach through the femoral artery is the preferred vascular access. Despite the improvements in the devices, femoral artery complications still occurs and some times this access is not possible because of the small size of the vessels, obstruction, calcification, dissection or extreme tortuosity.
View Article and Find Full Text PDFHorseshoe kidney is a rare congenital anomaly that may cause various technical problems during conventional repairs of abdominal aortic aneurysms. We report the case of a 68-year-old woman with a horseshoe kidney, symptomatic abdominal aortic aneurysm and mild renal failure. The patient underwent endovascular repair using a bifurcated endoprosthesis.
View Article and Find Full Text PDFObjective: The aim of this study was to assess whether the presence of procaine in crystalloid cardioplegic solution increases myocardial protection at the ultra structural level.
Methods: Eighteen patients that underwent aortic valve replacement in the Hospital de Clínicas de Porto Alegre over a 10-month period were studied. They were randomly allocated into two groups: group A--eight patients receiving cardioplegia without procaine; group B--ten patients receiving cardioplegia with procaine.
Objective: To compare the free blood flow, caliber, and length of the left internal thoracic artery (LITA), dissected in the pedicled (P) and skeletonized (S) manners, during surgery before and after topical vasodilator (TV) application.
Methods: A randomized, blind, clinical trial was carried out with 50 patients undergoing elective myocardial revascularization to assess the use of the LITA in situ in its pedicled or skeletonized form. The 25 patients in the pedicled group (GP) had NYHA class II or III angina, ejection fraction (EF) of 50.