Objective: To evaluate the in vitro influence of prior silane application on the microshear bond strength (μSBS) of Scotchbond Universal Plus to glass ceramic.

Materials And Methods: Thirty blocks of lithium disilicate ceramic were etched with hydrofluoric acid for 20 s and distributed into Group 1 (no silane and no adhesive), Group 2 (adhesive), Group 3 (silane + adhesive). Three cylinders of resin cement were made on each ceramic block.

View Article and Find Full Text PDF

The goal of this clinical report was to present an alternative to traditional flat bone reduction guides, using a custom-designed 3-dimensional (3D)-printed guide according to the future gingival margin of the planned dentition. A 61-year-old woman with concerns regarding her smile appearance was presented. The initial examination revealed excessive gingival show accompanied by excessive overjet.

View Article and Find Full Text PDF

This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed.

View Article and Find Full Text PDF

To evaluate whether dental crown topography influences the fracture resistance of premolars treated endodontically and with MOD preparation subjected to different restorative protocols. Sixty-four human premolars with one or two roots in equal numerical proportions (n) were selected and randomly divided into four groups (n = 8): (S = single-rooted; D = double-rooted) SS: sound single-rooted; SNR: endodontics (E) + MOD cavity preparation; SR: E + MOD + resin restoration (RS); SP: E + MOD + RS + horizontal zirconia post (ZP); DS: sound double-rooted; DNR: E + MOD; DR: E + MOD + RS; and DP: E + MOD + RS + ZP. After allocation to the groups, the samples were thermocycled and then subjected to the fracture resistance test.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures.

Materials And Methods: Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL.

View Article and Find Full Text PDF

Background: Because of the many possibilities for endodontically restoring the posterior teeth and the high prevalence of restoration failures, this topic continues to be of major concern. A composite resin (CR) restoration reinforced by a horizontal fiberglass post may improve the fracture resistance of endodontically treated teeth. The authors investigated this possibility by comparing the fracture resistance of molars restored with direct techniques with that of molars restored with indirect techniques.

View Article and Find Full Text PDF

Purposes: (1) To evaluate in vitro the surface roughness of a resin composite covered with three surface sealants and submitted to simulated toothbrushing for different periods; (2) Verify, through scanning electron microscopy (SEM), the presence of surface sealants after simulated toothbrushing; and (3) To evaluate whether the type of dentifrice influences the maintenance of the surface sealant. The study hypothesis was that neither variable would influence the surface roughness of the composite and the maintenance of the surface sealant.

Methods: 108 specimens were prepared with the resin Amelogen Plus, and divided into six groups (n = 18) according to the type of surface sealant [Fortify (F), BisCover LV (B) and Permaseal (P)] and toothpaste [Total 12 Clean Mint (CT) and Colgate Total 12 Professional Whitening (PW)].

View Article and Find Full Text PDF

Purpose: To clinically evaluate the performance of indirect composite resin restorations cemented with conventional and self-adhesive resin cements over a 12-month period.

Materials And Methods: Ten patients fulfilled all the inclusion criteria. Twenty-four composite resin restorations were performed using an indirect technique and cemented with a resin cement (RelyX ARC) or a self-adhesive resin cement (RelyX U100).

View Article and Find Full Text PDF

Purpose: To assess the fracture strength of cavity preparations, directly restored with resin composite, with and without the presence of fiberglass posts with different diameters.

Methods: 84 extracted third molars were embedded in acrylic resin and divided into six groups (n = 14 per group): healthy (H); cavity preparation (P); cavity preparation + endodontic treatment (PE); PE + resin composite (R); PE + R + 2 horizontally transfixed fiberglass posts 1.1 mm in diameter (PERP1); PE + R + 2 fiberglass posts 1.

View Article and Find Full Text PDF

Background: Because no information was found in the dental literature regarding the fracture resistance of all-ceramic crowns using CEREC (Sirona) computer-aided design and computer-aided manufacturing (CAD-CAM) system on solid abutments, the authors conducted a study.

Methods: Sixty synOcta (Straumann) implant replicas and regular neck solid abutments were embedded in acrylic resin and randomly assigned (n = 20 per group). Three types of ceramics were used: feldspathic, CEREC VITABLOCS Mark II (VITA); leucite, IPS Empress CAD (Ivoclar Vivadent); and lithium disilicate, IPS e.

View Article and Find Full Text PDF

Statement Of Problem: The optimum time after pouring a dental impression before removing the dental cast is unknown with regard to the strength and roughness of the stone. Setting times and the commercial products used are important variables.

Purpose: The purpose of this study was to evaluate the effect of postpouring time on the surface roughness, compressive strength, and diametric tensile strength of Type IV dental stone.

View Article and Find Full Text PDF

Objectives: The objective of the following study is to evaluate the interaction between the resin materials used in immediate dentin sealing (IDS) techniques and impression materials with two different techniques to eliminate the oxygen-inhibition layer.

Materials And Methods: The occlusal dentin surface of 35 human molars was exposed. The teeth were used in two Groups: Group 1 - Impression with Express XT; Group 2 - Impression with Impregum.

View Article and Find Full Text PDF

Unlabelled: OBJECTIVE. This study evaluated the influence of restorative techniques on the fracture load and fracture mode of endodontically treated premolars with MOD cavities.

Materials And Methods: Sixty maxillary premolars were divided into groups: G1 - sound teeth; G2 - direct technique using Four Season; G3 - Adoro inlays; G4 - Adoro onlays; G5 - Empress inlays; G6 - Empress onlays.

View Article and Find Full Text PDF

Objectives: To evaluate the influence of resin cements on cuspal deflection, fracture load and failure mode of endodontically-treated teeth restored with composite resin inlays.

Materials And Methods: Forty maxillary premolars were randomly divided into four groups: G1 (sound teeth, control), G2 (RelyX ARC), G3 (RelyX Unicem) and G4 (Maxcem Elite). The teeth from groups 2, 3 and 4 received mesial-occlusal-distal preparations and endodontic treatments.

View Article and Find Full Text PDF

Objective: The aim of this study was to investigate the effect of Nd:YAG and argon laser irradiations on enamel demineralization after two different models to induce artificial caries.

Background Data: It is believed that the use of the high-intensity laser on the dental structure can lead to a more acid-resistant surface.

Materials And Methods: Twenty-one extracted human third molars were sectioned into tooth quarters.

View Article and Find Full Text PDF

Purpose: Our study aimed to test the null hypothesis that whitening and non-whitening dentifrices affect similarly the surface roughness of commercial microhybrid composites, independent of the brushing time.

Materials And Methods: One hundred and ninety-two disc-shaped specimens of Filtek Z250 (3 M/ESPE, St. Paul, MN, USA) and Rok (SDI, Australia) were built up and randomly assigned to 24 groups, based on the dentifrices used (two whitening dentifrices: Colgate Max White-Colgate-Palmolive, São Bernardo do Campo, São Paulo, Brazil and Close Up Extra Whitening-Unilever, Brasil Higiene Pessoal e Limpeza Ltda, Ipojuca, Pernambuco, Brazil; and one non-whitening dentifrice: Colgate Total 12 Clean Mint-Colgate-Palmolive), and on the simulated brushing times (24 hours, 6, 12 and 24 months).

View Article and Find Full Text PDF

Objective: To compare, in vitro, the accuracy between dental stone casts obtained from the first and the second pour using metallic (Smart) and plastic (Triple Tray) dual-arch trays.

Material And Methods: The impressions were taken using Flexitime® vinyl polysiloxane from a typodont model with a mandibular right first molar prepared for a full crown. Ten impressions were made with each tray and poured using type IV die stone.

View Article and Find Full Text PDF

Objective: this study evaluated the effect of surface treatments (Nd:YAG laser, CO2 laser, Al203 airborne-particle abrasion, and silica-coating) on the zirconia-to-resin shear bond strength (SBS).

Method And Materials: eighty-one Lava (3M ESPE) blocks (13 x 4 x 2 mm) were embedded in acrylic resin, polished, and randomly divided into three groups, which received the following surface treatments: no abrasion, Al203 airborne-particle abrasion (50 Μm), or silica-coating (Cojet, 3M ESPE). Each group was divided into three subgroups that were treated with Nd:YAG laser, CO2 laser, or no laser irradiation.

View Article and Find Full Text PDF

Objective: Evaluate, in vitro, the microtensile bond strength (µTBS) of RelyX ARC conventional resin cement and RelyX Unicem and Maxcem self-adhesive resin cements to dentin, and the influence of polyacrylic acid pretreatment on the µTBS.

Material And Methods: Flat dentin surfaces were obtained in 15 third molars which were randomly divided into 5 groups: Group 1 - RelyX ARC (control); Group 2 - RelyX Unicem; Group 3 - Maxcem Elite; Group 4 - 22.5% polyacrylic acid and RelyX Unicem; Group 5 - 22.

View Article and Find Full Text PDF

Objectives: This study assessed the fatigue resistance and failure mode of type III porcelain and composite resin veneers bonded to custom zirconia implant abutments.

Material And Methods: Twenty-four standardized zirconia implant abutments were fabricated. Using the CEREC 3 machine, type III veneers of standardized shape were milled in ceramic Vita Mark II or in composite resin Paradigm MZ100.

View Article and Find Full Text PDF

Objective: This study analyzed the adhesive-dentin interface when Nd:YAG and Er:YAG lasers were applied to dentin.

Background Data: Lasers applied to dentin cause morphological changes of this tissue. Because adhesive systems bond to dentin through the hybrid layer, it is important to investigate the adhesive-dentin interface when dentin is irradiated with lasers.

View Article and Find Full Text PDF

Purpose: To assess the effect of a horizontally transfixed fiber glass post placed between buccal and palatal surfaces, on the fracture strength of endodontically treated molar teeth with MOD cavities, either restored with resin-based composite, or not.

Methods: 75 sound maxillary human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to five groups (n=15). Group A (sound teeth), (control) and Groups B, C, D and E, which were subjected to the following procedures after endodontic treatment: GB--(MOD+Endo), GC--(MOD+Endo+Post), GD--MOD and composite restoration (MOD+Endo+CR), GE--(MOD+Endo+Post+CR).

View Article and Find Full Text PDF

Background And Objectives: The Nd:YAG laser can be used in Dentistry to remove soft tissue, disinfect canals in endodontic procedures and prevent caries. However, there is no protocol for Nd:YAG laser application in dental bleaching. The aims of this in vitro study were: (a) to observe the tooth shade alteration when hydrogen peroxide whitening procedures are associated with dyes with different wavelengths and irradiated with Nd:YAG laser or halogen light; (b) to measure the Vickers (VHN) enamel microhardness before and after the whitening procedure; (c) to evaluate the tensile bond strength of two types of adhesive systems applied on bleached enamel; (d) to observe the failure pattern after bond strength testing; (e) to evaluate the pulpal temperature during the bleaching procedures with halogen light or laser; (f) to measure the kinetic reaction of hydrogen peroxide.

View Article and Find Full Text PDF

Unlabelled: The use of Finite Element Analysis (FEA) is becoming very frequent in Dentistry. However, most of the three-dimensional models presented by the literature for teeth are limited in terms of geometry. Discrepancy in shape and dimensions can cause wrong results to occur.

View Article and Find Full Text PDF

Unlabelled: The purpose of this study was to assess bond strength of three self-etching and two total-etch adhesive systems bonded to primary tooth enamel and dentin.

Materials And Methods: Forty extracted primary human molars were selected and abraded in order to create flat buccal enamel and occlusal dentin surfaces. Teeth were assigned to one of the adhesive systems: Adper Scotch Bond Multi Purpose, Adper Single Bond 2, Adper Prompt L-Pop, Clearfil SE Bond and AdheSE.

View Article and Find Full Text PDF