Rev Esp Cardiol (Engl Ed)
September 2024
Introduction And Objectives: Thrombocytopenia frequently occurs after transcatheter aortic valve implantation (TAVI) but its impact is poorly understood. We aimed to analyze the incidence, clinical impact, and predictors of acquired thrombocytopenia after TAVI.
Methods: This retrospective multicenter registry included 3913 patients undergoing TAVI with a baseline platelet count of ≥ 100 *10/L.
Background: Initial data about the performance of the new-generation SAPIEN 3 Ultra (S3U) valve are highly promising. However, evidence about the longer-term performance and safety of the S3U is scarce.
Aims: We aimed to investigate the 1-year clinical and echocardiographic outcomes of transcatheter aortic valve implantation (TAVI) using the S3U compared with its predecessor, the SAPIEN 3 valve (S3).
Rev Salud Publica (Bogota)
September 2019
Objetive: Acute pancreatitis of biliary origin is a common gastrointestinal pathology, in which timely management still is the most important. The aims of this research is establish the socioeconomic impact in the current management of severe acute pancreatitis of biliary origin comparing two centers of the third level, one of high socioeconomic population and another of low in Bogotá, Colombia.
Materials And Methods: A retrospective, cross-sectional comparative study was conducted between January 2012 and December 2017, in two hospitals of Bogotá DC.
Background: Data on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited.
Objectives: The aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference.
Methods: In a multicenter registry (n = 17), 13 centers exhibited valve preference (66.
Background: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR.
Methods And Results: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro (n = 130), Acurate-neo (n = 79), Portico (n = 75) and Allegra (n = 60)] were included.
Objectives: Unplanned hospital readmissions after transcatheter aortic valve replacement (TAVR) are frequent and have been associated with a poor prognosis. We sought to determine the trends in the incidence and causes of unplanned hospital readmission after TAVR in patients receiving new-generation devices (NGDs) vs early-generation devices (EGDs).
Methods: The study population consisted of 1802 consecutive TAVR recipients (863 EGDs and 939 NGDs).
Transcatheter aortic valve replacement (TAVR) is an established treatment for patients with symptomatic severe aortic stenosis. In recent years, an emphasis has been placed on simplification of the procedure. Balloon predilation was initially considered a mandatory step to cross and prepare the stenotic aortic valve, but several studies demonstrated the feasibility of performing TAVR without balloon valvuloplasty.
View Article and Find Full Text PDFObjective: Left atrial appendage (LAA) thrombus has heretofore been considered a contraindication to percutaneous LAA closure (LAAC). Data regarding its management are very limited. The aim of this study was to analyse the medical and invasive treatment of patients referred for LAAC in the presence of LAA thrombus.
View Article and Find Full Text PDFObjectives: The purpose of this study was to examine the impact of residual mitral regurgitation (MR) on mortality in patients undergoing transcatheter aortic valve replacement (TAVR).
Background: MR is common in patients undergoing TAVR. Data on optimal management of patients with significant MR after TAVR are limited.
Background: Very few data exist on percutaneous mitral valve repair (PMVr) in unstable patients with concomitant moderate-severe mitral regurgitation (MR). The purpose of this systematic review was to evaluate baseline characteristics, management and clinical outcomes of critically ill patients undergoing PMVr with MitraClip.
Methods: We conducted a systematic review of the published data on MitraClip from its first use in 2003 to December 2020.
Purpose: Recent data suggests that high burden of premature atrial complexes after pulmonary vein isolation predicts recurrences of atrial arrhythmias. The present study sought to assess the role of premature atrial complexes burden in predicting atrial arrhythmias recurrences in patients with atrial fibrillation (AF) who have undergone second-generation cryoballoon ablation (CB-Adv).
Methods: Consecutive patients with drug-resistant paroxysmal atrial fibrillation who underwent pulmonary vein isolation using CB-Adv technology as the index procedure were retrospectively included.
J Interv Card Electrophysiol
August 2017
Purpose: The second-generation cryoballoon (CB-A, Arctic Front Advance, Medtronic, Minneapolis, MN, USA) has proven to be highly effective in achieving freedom from atrial fibrillation; nonetheless, the ideal number and duration of freezing cycles is still a matter of debate. We investigated the acute success, procedural complications, and clinical outcome of a single freeze strategy using the CB-A in a large, retrospective, international multicenter study.
Methods: Between January 2013 and September 2015, 818 consecutive patients (58 ± 12 years, 68% males) with drug-resistant atrial fibrillation (AF) who underwent a CB-A using a single freeze strategy were taken into consideration for our analysis.
J Opt Soc Am A Opt Image Sci Vis
March 2005
The spatial orientation of the fringe has been demonstrated to be a key point in the reliable phase demodulation from a single n-dimensional fringe pattern regardless of the frequency spectrum of the signal. The recently introduced general n-dimensional quadrature transform (GQT) makes explicit the importance of the fringe orientation in the demodulation process. The GQT is a quadrature operator that transforms cos phi into -sin phi--where phi is the modulating phase--and it is composed of two terms: an orientation factor directly related to the fringe's spatial orientation and an isotropic n-dimensional generalization of the one-dimensional Hilbert transform.
View Article and Find Full Text PDF