Publications by authors named "Luis M Polo-Diez"

A two-dimensional achiral-chiral LC-LC method in heart-cut mode for ketoprofen and its enantiomeric fraction determination was proposed. A C column was used in the first dimension, and the chiral column was an α-acid glycoprotein. The mobile phase of the chiral system was optimized by a factorial design.

View Article and Find Full Text PDF

Background: The aim of this study was to develop an efficient method for cholesterol oxide product (COP) determination in irradiated and non-irradiated ready-to-eat foods with high water content by gas chromatography-flame ionisation detector after accelerated solvent extraction (ASE), and derivatisation with a silylating reagent.

Results: The ASE solvent was an 85:15 v/v petroleum ether/chloroform mixture at 40 °C and 1500 psi followed by solid phase extraction. The ASE method was compared with the established lixiviation method, proving an advantageous alternative which reduces analysis time by a factor of 15 and solvent volume by 50%, and minimises the use of chlorinated solvents.

View Article and Find Full Text PDF

A direct chiral LC-UV method was optimized for the determination of salbutamol (SAL) β2 -agonist in environmental water. Two commercially available columns were evaluated: teicoplanin Chirobiotic-T™ (150 × 2.1 mm i.

View Article and Find Full Text PDF

Changes in free amino acids content and its potential racemization in ready-to-eat foods treated with E-beam irradiation between 1 and 8 kGy for sanitation purposes were studied. A simple heart cut two-dimensional high performance liquid chromatographic method (LC-LC) for the simultaneous enantiomeric determination of three pairs of amino acids used as markers (tyrosine, phenylalanine, and tryptophan) is presented. The proposed method involves the use of two chromatographs in an LC-LC achiral-chiral coupling.

View Article and Find Full Text PDF

Difficulties detected in the determination of the diethylhexylphthalate (DEHP) at trace levels by gas chromatography-mass spectrometry (GC-MS) using SPME, due to its ubiquitous distribution in the environment has been overcome and a new method for the determination of DEHP in drinking water has been proposed. The method is based on solid phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC). Detection was carried out spectrophotometrically.

View Article and Find Full Text PDF

Simple one- and two-dimensional high-performance liquid chromatography (HPLC) methods for the simultaneous enantiomeric determination of alkyloxyphenoxypropionic acid herbicides is presented. Compounds studied were ( R, S)-2-[4-(2,4-dichlorophenoxy)phenoxy]propionic acid (diclofop-acid) and ( R, S)-2-[4-(2,4-dichlorophenoxy)]methyl propionate (diclofop-methyl). Mobile phases necessary to separate their enantiomers on an alpha1-acid glycoprotein chiral stationary phase are different; therefore, the simultaneous separation by an isocratic mode is not possible.

View Article and Find Full Text PDF