Bone loss in the alveolar ridge is a factor widely studied by dentists in implant surgeries, as it poses a major challenge for aesthetic and functional recovery in patients with large maxillary bone defects. Synthetic biomaterials function as grafts designed to replace and remodel bone tissue. Calcium phosphate is a biomaterial that has good properties such as biocompatibility and bioactivity, making it a reference in bone replacement treatments.
View Article and Find Full Text PDFDent Mater J
July 2024
Dent Mater J
January 2024
This study evaluated the influence of different translucent resins (Z350 and Opallis) for customizing fiber posts and light-curing the cementation system using different LED equipment (V, Valo or R, Radii-Cal) on the bond strength and adhesive failure pattern at 24 h and 6 months. Eighty roots were prepared and divided into 4 groups (n=20): ZV (Z350 resin and LED Valo), ZR (Z350 resin and LED Radii-Cal), OV (Opallis resin and LED Valo), OR (Opallis resin and LED Radii-Cal). After post space preparation, the fiber post was customized and cemented with self-adhesive cement and light-curing using V or R LED equipment.
View Article and Find Full Text PDFDent Mater J
January 2024
The objective of the study was to evaluate the effects of dentin deproteinization protocols for post space using different formulations containing sodium hypochlorite before fiber post cementation with self-adhesive resinous cement. The groups were divided according to the irrigation protocol (DWC, SHS, SHT and SHG). The residue cleanliness, bond strength, adhesive failure pattern, and tag formation at the adhesive interface between the self-adhesive cement and the dentin were evaluated.
View Article and Find Full Text PDFThe study evaluated the persistence of residues, bond strength and tags formation of a cementation system after post-space irrigation with different sodium hypochlorite-based irrigants. The groups were divided according to the irrigation protocol (DW: distilled water; SHS: sodium hypochlorite solution; SHG: sodium hypochlorite gel; and, SHT: sodium hypochlorite with surfactant). Forty roots (n=10) were used to evaluate the persistence of residues by scanning electron microscopy.
View Article and Find Full Text PDFThis study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10- 15- and 30-min.
View Article and Find Full Text PDFHigh implant survival rates have been achieved in recent decades due to continual modifications in implant design and surface topography, however there is still an ongoing quest to control peri-implant bone loss. The objective of this work was to develop Ti-35Nb-7Zr-5Ta (TNZT) alloys, perform physicochemical and morphological characterization of their surface modified by electrolytic oxidative plasma technique with ions related to osseointegration and lastly evaluate bacterial colonization in vitro. Three groups were evaluated: C group (polished TNZT), CaP group (sodium β glycerophosphate + calcium acetate) and Mg group (magnesium acetate).
View Article and Find Full Text PDFThe titanium alloy composition and microdesign affect the dynamic interplay between the bone cells and titanium surface in the osseointegration process. The current study aimed to evaluate the surface physicochemical properties, electrochemical stability, and the metabolic response of the MC3T3-E1 cells (pre-osteoblast cell line) cultured onto titanium-15molybdenum (Ti-15Mo) discs treated with phosphoric acid (HPO) and sodium hydroxide (NaOH) and/or strontium-loading by the hydrothermal method. The x-ray dispersive energy spectroscopy (EDS) and x-ray diffraction (XRD) analysis showed no trace of impurities and the possible formation of hydrated strontium oxide (HOSr), respectively.
View Article and Find Full Text PDFThis study evaluated the microbial colonization (adhesion and biofilm) on modified surfaces of a titanium alloy, Ti-35Nb-7Zr-5Ta, anodized with Ca and P or F ions, with and without silver deposition. The chemical composition, surface topography, roughness (Ra), and surface free energy were evaluated before and after the surface modifications (anodizing). Adhesion and biofilm formation on saliva-coated discs by primary colonizing species (, , ) and a periodontal pathogen () were assessed.
View Article and Find Full Text PDFThe aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control.
View Article and Find Full Text PDFIntroduction: Computer-aided design and manufacturing (CAD-CAM) systems have assisted orthodontists to position brackets virtually. The purpose of this study was to evaluate if a CAD-CAM system could predict the orthodontic treatment outcome of patients with Angle Class I malocclusion with mild crowding or spacing and with no need for orthodontic extraction.
Methods: Using the American Board of Orthodontics Cast-Radiograph Evaluation (ABO-CRE) and color map superimposition, the treated occlusion was compared with the virtual final occlusion of 24 young adults with Class I occlusion.
Objective: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified.
Methods: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation).
The chemical composition of biomaterials can drive their biological responses; therefore, this in vitro study aimed to evaluate the proteomic profile of the salivary pellicle formed on titanium (Ti) alloys containing niobium (Nb) and zirconium (Zr). The experimental groups consisted of Ti35NbxZr (x = 5 and 10 wt%) alloys, and commercially pure titanium (cpTi); titanium aluminium vanadium (Ti6Al4V) alloys were used as controls. The physical and chemical characteristics of the Ti materials were analysed.
View Article and Find Full Text PDFClin Implant Dent Relat Res
June 2018
Background: Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process.
Purpose: The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric changes in the apex region of dental implants.
Methods: Thirty-five cylindrical dental implants (Titamax Ti; Neodent) were machined at the apical third to reproduce the experimental groups: without apical cut (Wc), apical bi-split cut, apical tri-split cut, apical quadri-split cut (Qs).
Objective: The aim of this study was to develop binary and ternary titanium (Ti) alloys containing zirconium (Zr) and niobium (Nb) and to characterize them in terms of microstructural, mechanical, chemical, electrochemical, and biological properties.
Methods: The experimental alloys - (in wt%) Ti-5Zr, Ti-10Zr, Ti-35Nb-5Zr, and Ti-35Nb-10Zr - were fabricated from pure metals. Commercially pure titanium (cpTi) and Ti-6Al-4V were used as controls.
Dental composites cured at high temperatures show improved properties and higher degrees of conversion; however, there is no information available about the effect of pre-heating on material degradation. Objectives This study evaluated the effect of pre-heating on the degradation of composites, based on the analysis of radiopacity and silver penetration using scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDS). Material and Methods Thirty specimens were fabricated using a metallic matrix (2x8 mm) and the composites Durafill VS (Heraeus Kulzer), Z-250 (3M/ESPE), and Z-350 (3M/ESPE), cured at 25°C (no pre-heating) or 60°C (pre-heating).
View Article and Find Full Text PDFObjective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design.
Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.
Statement Of Problem: In dental rehabilitations that involve implants, the number of implants is sometimes smaller than the number of lost teeth. This fact can affect the biomechanical behavior and success of the implants.
Purpose: The purpose of this study was to investigate the mechanical behavior of different implant positions in the rehabilitation of the anterior maxilla.
The main aim of this work was to assess the electrochemical behavior of new Ti35Nb5Zr and Ti35Nb10Zr alloys in artificial saliva at 37 °C to verify if they are indicated to be used as biomaterials in dentistry as alternatives to Ti6Al4V alloys in terms of corrosion protection efficiency of the material. Electrochemical impedance spectroscopy (EIS) experiments were carried out for different periods of time (0.5-216 h) in a three-electrode cell, where the working electrode (Ti alloys) was exposed to artificial saliva at 37 °C.
View Article and Find Full Text PDFPurpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants.
Materials And Methods: Computed tomography (CT)-based finite element models comprising a maxillary central incisor socket and four commercially available internal-connection implants (SIN SW, 3i Certain, Nobel Replace, and ITI Standard) of comparable diameters and lengths were constructed. Biomechanical scenarios of immediate placement, immediate loading, and delayed loading protocols were simulated.
This study evaluated fatigue strength of CP-Ti laser-welded joints. Sixty (20/diameter) CP-Ti casted dumbbell rods with diameters of 1.5, 2.
View Article and Find Full Text PDFPurpose: Numerous "in vitro" investigations have been conducted to evaluate the role of screw size and pattern in determining optimal resistance to deformation, often these have been controversial. The aim of this study was to evaluate the effect of screw size and insertion technique on the stability of sagittal split osteotomies.
Materials And Methods: This study used twenty polyurethane replicas of human hemimandibles with a prefabricated sagittal split ramus osteotomy (SSRO).
Purpose: To evaluate the influence of platform switching on the biomechanical environment of implants in different placement and loading protocols.
Materials And Methods: A computed tomography-based finite element model of a maxillary central incisor extraction socket was constructed containing a conical 13-mm external-hex implant with a 4.3-mm-diameter shoulder.