Publications by authors named "Luis Felipe Jochims Schneider"

Background: Light-cured resins are widely used as gingival barriers to protect the gums from highly concentrated peroxides used in tooth bleaching. The impact of barrier brand on clinical outcomes is typically considered negligible. However, there is limited evidence on the effects of different brands on operator experience, barrier adaptation, and patient comfort.

View Article and Find Full Text PDF

Statement Of Problem: Visual shade selection in dentistry may be influenced by factors that include the background color and the illuminant.

Purpose: The purpose of this clinical study was to evaluate the influence of using a gray background and a light-correcting device on visual shade selection.

Material And Methods: Two experienced clinicians assessed the incisor color of 30 volunteers using the VITA 3D-MASTER shade guide.

View Article and Find Full Text PDF

This retrospective cohort study aimed to evaluate the efficiency of supportive periodontal treatment (SPT) on peri-implant disease prevention. A total of 63 rehabilitated patients with 504 implants were selected with both maxillary and mandibular Brånemark-type protocols (all-on-four system) placed between 2004 and 2014 in a private practice with 5 to 15 years of follow-up. Study participants were divided into those who adhered to SPT with regular intervals of two or more times a year (Group 1) and those with irregular intervals with more than 1 year without attending SPT (Group 2).

View Article and Find Full Text PDF

Through the use of the application of a mathematical proportion and a digital golden ratio compass associated with computer software, Digital Smile Planning (DSP) can assist clinicians to achieve the fundamentals of esthetic treatment. The present clinical report describes the application of this technique to propose an alternative and more conservative treatment for a patient who refused the option of orthognathic surgery. To address the diagnosis of a gingival smile with vertical maxillary excess, the alternative treatment comprised crown lengthening surgery, ceramic veneers on the maxillary teeth, and the application of botulinum toxin to reduce lip hyperactivity.

View Article and Find Full Text PDF

This study determined the effect of thiourethane-functionalized fillers (TU) on the antimicrobial properties, cytotoxicity, degree of conversion (DC), water sorption (Wsp) and solubility (Wsl) of experimental composites. TU-modified fillers were added at different ratios in experimental composites: 0 (Control-TU0), 25% (TU25), 50% (TU50), 75% (TU75) and 100wt% (TU100). The antimicrobial properties were detected through the exhaustion test and counting of Streptococus mutans colonies for biofilm formation.

View Article and Find Full Text PDF

Objective: To determine the effect of organosilane content on the physicochemical properties of model composites formulated with nano-sized fillers.

Methods: Model composites were formulated with dimethacrylate-based monomers, a photoinitiator/co-initiator system and silicon dioxide nano-sized fillers treated with different amounts of 3-methacryloxypropyltrimethoxysilane (MPTS): 1.0 (G), 2.

View Article and Find Full Text PDF

This study aimed to evaluate the long-term clinical success of the use of mineral trioxide aggregate (MTA) as a sealant material in root perforation treatments. Therefore, the dental records of 53 patients were analyzed, and treatment data was collected (age, gender, tooth location, jaw, presence or absence of radiolucent lesion, fallow up time and final radiographic/clinical assessment). All procedures were performed by a single specialist.

View Article and Find Full Text PDF

Aim: The aim of this study was to compare the restorative time required and the internal adaptation after thermomechanical aging of class I restorations using either the conventional incremental technique or bulk-fill technique.

Materials And Methods: Cavities (Class I) were prepared on the occlusal surface of human third molars. 40 teeth were divided into four experimental groups according to the restorative technique (n = 10): G1 = 3 mm increment of Surefill SDR Flow + 1 mm Filtek P60; G2 = 3 mm increment of Filtek Bulk-Fill + 1 mm Filtek P60; G3 = Filtek P60 inserted with incremental technique; G4 = 3 mm increment of Filtek Z350 Flow XT + 1 mm increment of Filtek P60.

View Article and Find Full Text PDF

Objective: Investigate antimicrobial properties and surface texture of model composites with different concentration and alkyl chain length of quaternary ammonium monomers (QAS).

Methods: Monomers derived from QAS salts with alkyl chain lengths of 12 carbons ((dimethylaminododecyl methacrylate) DMADDM) and 16 carbons (dimethylaminohexadecyl methacrylate-DMAHDM) were obtained from the reactions of their respective organo-halides with the tertiary amine 2-(dimethylamino)ethyl methacrylate (DMAEMA). DMADDM and DMAHDM were incorporated into model composite in concentrations of 5 or 10%, resulting the following groups: G12.

View Article and Find Full Text PDF

Unlabelled: This study evaluated the surface texture and optical properties of two self-adhering composites and a nanofilled composite before and after toothbrush abrasion. Vertise Flow (Kerr), Fusio Liquid (Pentron Clinical) and Filtek Z350 XT (3M ESPE) composites were divided into 3 groups (n = 6). Disks of 12 mm diameter and 2 mm thick were made.

View Article and Find Full Text PDF

Objective: to determine the physicochemical properties of experimental adhesive resins containing hydroxyethyl acrylamide.

Methods: Three groups of experimental resin were formulated, GHEAA33% (33.3wt% HEAA+66.

View Article and Find Full Text PDF

The aim of this study was to determine the degradation resistance of three new formulations-silorane-, Ormocer- and dimer-acid-based materials-and compare them to the traditional dimethacrylate-based materials. One silorane- (Filtek P90, P90), one Ormocer- (Ceram-X, CX), one dimer-acid- (N'Durance, ND) and two dimethacrylate-based (Filtek P60, P60; Tetric Ceram, TC) materials were investigated. Water sorption (Wsp) and solubility (Wsl) were determined after the materials were immersed in water for 28 days.

View Article and Find Full Text PDF

Objectives: To investigate the influence of matrix and filler content on degradation resistance of an experimental pure-ormocer and an dimethacrylate-based composite derived from a commercially available material.

Materials And Methods: A dimethacrylate- Grandio (GR) and a model pure ormocer-based-matrix ORMOCER (ORM) were used. Each material had three different types according to their filler content (% w/w): regular (87% and 86%), flowable (80% and 79%) and fissure sealer (70% and 69%) for GR and ORM respectively.

View Article and Find Full Text PDF

The aim of this study was to evaluate: (i) the absorption of photo-initiators and emission spectra of light curing units (LCUs); and (ii) the degree of conversion (DC) of experimental composites formulated with different photo-initiators when activated by different LCUs. Blends of BisGMA, UDMA, BisEMA and TEGDMA with camphorquinone (CQ) and/ or 1-phenyl-1,2-propanedione (PPD) were prepared. Dimethylaminoethyl methacrylate (DMAEMA) was used as co-initiator.

View Article and Find Full Text PDF

Aim: The aim of this study was to investigate the effect of different incremental insertion techniques, photoactivation, and restorative phases on thermal variations occurring during the polymerization of Filtek Z250 composite resin.

Methods And Materials: The experiment was conducted using 90 bovine incisor teeth. The teeth were randomly assigned to three groups according to the technique used for photoactivation with a halogen light (continuous, soft-start, or intermittent).

View Article and Find Full Text PDF

The aim of this investigation was to verify the influence of 3 light curing units on the degree of conversion, using different irradiation conditions: 1) manufacturers' recommended times of photo-activation, 2) standardizing total energy density among the units and 3) standardizing energy density at the 450-490 nm wavelength range among the units and the effect of these irradiation conditions on the post-cure. Three light curing units were used: halogen, light emitting diodes (LED) and xenon plasma. Seven groups were tested (n=6).

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of the increase of energy density on Knoop hardness of Z250 and Esthet-X composite resins. Cylindrical cavities (3 mm in diameter X 3 mm in depth) were prepared on the buccal surface of 144 bovine incisors. The composite resins were bulk-inserted and polymerized using different light-curing units and times: conventional QTH (quartz-tungsten-halogen; 700 mW/cm(2); 20 s, 30 s and 40 s); LED (light-emitting diode; 440 mW/cm(2); 20 s, 30 s and 40 s); PAC (xenon plasma arc; 1700 mW/cm(2); 3 s, 4.

View Article and Find Full Text PDF

This study verifies whether there is any temperature change during photoactivation of two resin composites (Filtek Z250 and Filtek Flow) with three different light curing methods (conventional halogen light curing unit, light emitting diodes curing unit and xenon plasma arc curing unit) and the relationship of temperature change with resin composite hardness. A type-K thermocouple registered the temperature rise peak in an elastomer mold during photoactivation. After photoactivation, the specimens were submitted to Knoop hardness test performed by an indenter (HMV-2000) under a load of 50g for 15 seconds.

View Article and Find Full Text PDF