Background: Transcatheter aortic valve replacement is approved for treatment of patients with severe aortic stenosis across the spectrum of risk. While considering broader indications for use, transcatheter aortic valve replacement in large native annuli has become increasingly important.
Methods: Patients with tricuspid aortic stenosis undergoing transcatheter aortic valve replacement using the Evolut R or Evolut PRO+ 34 mm valves (Medtronic, Minneapolis, MN) in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry between October 2016 and September 2020 were stratified according to in range (>12%) device oversizing and below range (0%-12%) device oversizing.
Objective: The objective of this study is to evaluate protamine sulfate effects on graft's blood flow by comparing transit-time flow measurement (TTFM) values before and after protamine administration.
Methods: This is an observational study with data collected between years 2018 and 2020. Immediate graft patency was evaluated using TTFM.
Objectives: To assess the safety profile of redo-TAVR procedures from patients in the transcatheter valve therapy (TVT) Registry.
Background: The use of transcatheter aortic valves (TAV) to treat previously implanted failing TAVS (TAV-in-TAV) has been an increasingly important topic as indications for TAVR move to younger and lower-risk patients, but data on the safety and efficacy of redo-TAVR is limited.
Methods: Patients undergoing redo-TAVR procedures using the Evolut R, Evolut PRO or Evolut PRO+ valve in the TVT Registry between April 2015 and March 2020 were included.
Background Transcatheter aortic valve replacement with supra-annular transcatheter heart valves has been adopted in patients with degenerated surgical aortic valves. The next generation self-expanding Evolut PRO valve has not been evaluated in patients with surgical valve failure. Methods and Results Patients undergoing transcatheter aortic valve replacement in degenerated surgical aortic valve procedures using the Evolut R or Evolut PRO transcatheter heart valves in the Society of Thoracic Surgeons and American College of Cardiology Transcatheter Valve Therapy Registry between April 2015 and June 2019 were evaluated.
View Article and Find Full Text PDFObjectives: This study sought to compare outcomes following transcatheter aortic valve replacement when valve repositioning was performed (repositioned group) versus procedures without repositioning (nonrepositioned group).
Background: The Evolut R and Evolut PRO valves were designed to allow repositioning during deployment, yet the effect of repositioning on clinical outcomes remains unclear.
Methods: Patients implanted with the Evolut R or PRO valve from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial continued access study and the Evolut Low Risk Trial between June 2016 and November 2018 were combined.
Left ventricular aneurysm is a late mechanical complication of untreated acute myocardial infarction. It has become relatively rare since the development of percutaneous cardiac intervention. Most aneurysms are located at the anterior ventricular wall, and are caused by total occlusion of the left anterior descending artery.
View Article and Find Full Text PDFCardiovasc Revasc Med
January 2021
The rate of in-stent restenosis (ISR) has become increasingly prevalent with the exponential growth in stent implantation due to an aging population and a higher life expectancy, in addition to the high rates of obesity and diabetes. In this prospective, single operator, all-comer study, we sought to analyze the performance of ELCA followed by bioresorbable vascular scaffold (BVS) placement in patients undergoing percutaneous coronary intervention (PCI) for ISR. A total of 13 patients had ISR treated with a combination of ELCA and BVS, with 9 patients having matched OCT pre, post ELCA and post BVS.
View Article and Find Full Text PDFIn this work, a strain-based degradation model was implemented and validated to better understand the dynamic interactions between the bioresorbable vascular scaffold (BVS) and the artery during the degradation process. Integrating the strain-modulated degradation equation into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both strut thinning and discontinuity of the stent struts within an artery were captured and visualized.
View Article and Find Full Text PDF