The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS).
View Article and Find Full Text PDFToday the armed forces and law enforcement personnel wear body armor, helmets, and flak jackets composed substantially of Kevlar® fiber to prevent bodily injury or death resulting from physical, ballistic, stab, and slash attacks. Therefore, there is a high probability that during a radiation accident or its aftermath, the Kevlar®-composed body armor will be irradiated. Preliminary study with samples of Kevlar® foundation fabric obtained from body armor used by the U.
View Article and Find Full Text PDFA summary of recent developments in fingernail EPR dosimetry is presented in this paper. Until 2007, there had been a very limited number of studies of radiation-induced signals in fingernails. Although these studies showed some promising results, they were not complete with regard to the nature of non-radiation signals and the variability of dose dependence in fingernails.
View Article and Find Full Text PDFRadiat Prot Dosimetry
February 2009
An extension of dosemeter issue period brings significant economic and logistic benefits. Therefore, it is desirable to have an extended period as long as possible without significant loss of the quality of dose measurements. There are many studies devoted to the investigation of fading or reduction of the dose accumulated in dosemeters with time.
View Article and Find Full Text PDFFiber-optic-coupled radioluminescent (FOC) dosimeters are members of a new family of dosimeters that are finding increased clinical applications. This study provides the first characterization of a Cu doped quartz FOC dosimeter at diagnostic energies, specifically across the range of x-ray energies and intensities used in mammographies. We characterize the calibration factors, linearity, angular dependence, and reproducibility of the FOC dosimeters.
View Article and Find Full Text PDFFive high-sensitivity metal oxide semiconductor field effect transistor dosimeters in the TN-502 and 1002 series (Thomson Nielsen Electronics Ltd., 25B, Northside Road, Ottawa, ON K2H8S1, Canada) were evaluated for use in the mammography x-ray energy range (22-50 kVp) as a tool to assist in the documentation of patient specific average glandular dose. The dosimeters were interfaced with the Patient Dose Verification System, model No.
View Article and Find Full Text PDF