Objectives: The relationship between glucose metabolism and tumor cellularity before chemo-radiotherapy in patients with head and neck squamous cell carcinoma (SCC) has never been compared with that of patients evaluated after treatment. This retrospective study analyzed the correlation between glucose metabolism parameters expressed by standardized uptake value (SUV) derived from 18F-fluorodeoxyglucose (18F-FDG) PET/CT and cellularity tumor parameters expressed by apparent diffusion coefficients (ADC) derived from diffusion-weighted (DW) MRI in untreated and treated patients with head and neck SCC.

Methods: In 19 patients with no previous exposure to any treatment and 17 different chemo-radiotreated patients with head and neck SCC, we correlated the semi-quantitative uptake values (SUVmax, SUVpeak, and SUVmean) with the ADC functional parameters (ADCmin, ADCmean) including the standard deviation of ADC values (ADCsd).

View Article and Find Full Text PDF

Purpose: The clinical introduction of a radioactive and fluorescent hybrid tracer allowed for preoperative lymphatic mapping and intraoperative real-time fluorescence tracing of the sentinel lymph node (SLN) by a single injection. The aim of this feasibility study is to evaluate the first-in-human use of the hybrid tracer by combining indocyanine green (ICG) and radiocolloid based on Nanotop compound (99mTc Nanotop) for SLN biopsy (SLNB) in breast cancer patients.

Methods: The day before surgery, ICG-99mTc Nanotop was injected periareolarly in breast cancer patients scheduled for SLNB.

View Article and Find Full Text PDF

We compared the detection rate (DR) for sentinel lymph nodes (SLN), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus.

View Article and Find Full Text PDF

Background: The management of papillary thyroid carcinoma (PTC) is changed after introduction of sentinel lymph node biopsy (SNB) technique for nodal staging. Some debate still surrounds the accuracy of this procedure in terms of wide heterogeneity of sentinel lymph node detection and false-negative findings.

Aim: to identify the key issues which make it difficult the usefulness of SNB in PTC.

View Article and Find Full Text PDF

We reported the preoperative radio-guided localization of 4 peritoneal metastatic nodules in the case of a 45-year-old woman with uterine leiomyosarcoma. Three lines of chemotherapy were tried, but cardiotoxicity occurred. Within the context of so-called GOSTT (guided intraoperative scintigraphic tumor targeting), preoperative radio-guided localization of peritoneal metastases enabled their subsequent radio-guided excisional biopsy.

View Article and Find Full Text PDF

Purpose: BRAF V600E mutation papillary thyroid cancer (PTC) is more aggressive with a higher risk of lymph node involvement and a poorer prognosis. Prior studies failed to demonstrate the superiority of prophylactic lymphadenectomy. We investigated the utility of additional radio-guided sentinel node biopsy (SNB).

View Article and Find Full Text PDF

Purpose: The aim of this study was to compare reported results on available techniques for sentinel lymph node detection rate (SDR) in papillary thyroid cancer (PTC).

Methods: The MEDLINE database was searched via a PubMed interface to identify original articles regarding sentinel lymph node biopsy (SNB) in thyroid cancer. Studies were stratified according to the sentinel lymph node (SLN) detection technique: vital-dye (VD), Tc-nanocolloid planar lymphoscintigraphy with the use of intraoperative hand-held gamma probes (LS), both Tc-nanocolloid planar lymphoscintigraphy with intraoperative use of hand-held gamma probe and VD (LS + VD), Tc-nanocolloid planar lymphoscintigraphy with the additional contribution of preoperative SPECT/CT, and intraoperative use of hand-held gamma probe (LS-SPECT/CT).

View Article and Find Full Text PDF

Background: Current magnetic resonance imaging (MRI) techniques for measuring extraocular muscle (EOM) volume enlargement are not ideally suited for routine follow-up of Graves' ophthalmopathy (GO) because the difficulty of segmenting the muscles at the tendon insertion complicates and lengthens the study protocol.

Purpose: To measure the EOM sampled volume (SV) and assess its correlation with proptosis.

Material And Methods: A total of 37 patients with newly diagnosed GO underwent 3-T MRI scanning with iterative decomposition of water and fat (IDEAL) sequences with and without contrast enhancement.

View Article and Find Full Text PDF

Purpose: Sentinel lymph node biopsy (SNB) in patients with papillary thyroid carcinoma (PTC) and negative for clinically neck lymph node metastatic involvement (N0) has emerged as a promising minimally invasive procedure to detect metastatic nodes.

Methods: The MEDLINE database was searched via the PubMed interface on 10 January 2018 for the MeSH headings "sentinel lymph node biopsy" and "thyroid carcinoma".

Results: Vital blue dye, radioisotope, and the combination of both techniques are used in PTC patients.

View Article and Find Full Text PDF