Publications by authors named "Lucio P Neves"

Purpose: Uterine fibroids affect women mainly of childbearing age, an alternative for the treatment of these fibroids is uterine artery embolization (UAE), a minimally invasive procedure which uses fluoroscopy, providing radiation doses often high, due to the fact that professionals remain in the room throughout the procedure. In this work, equivalent and effective doses were evaluated for the main physician, for the assistant and for the patient during the UAE procedure.

Methods: Doses were calculated using computer simulation with the Monte Carlo Method, and virtual anthropomorphic phantoms, in a typical scenario of interventional radiology with field sizes of 20 × 20, 25 × 25 and 32 × 32 cm, tube voltages of 70, 80, 90 and 100 kV, and projections of LAO45, RAO45 and PA.

View Article and Find Full Text PDF

The influence of the angular deviation of the tube during digital breast tomosynthesis (DBT) acquisition to the dose in the examined breast and in other organs and tissues is not well known. In this work, the Monte Carlo method was used with an adult female virtual anthropomorphic phantom to investigate the impact of this angular variation on the breast dose. The absorbed dose in the examined breast was normalized by the air kerma, which resulted in an absorbed dose coefficient (DT/Kair) for the breast.

View Article and Find Full Text PDF

The objective of this study was to estimate the risk of radiation-induced injury to the organs due to ionizing radiation following breast screening recommendations employing digital breast tomosynthesis (DBT) and digital mammography (DM). Using the Monte Carlo method, absorbed doses in the tissues and organs were calculated on an adult female phantom, considering two-view craniocaudal (CC) and mediolateral oblique (MLO) projections for each breast. The results showed differences in the total effective risk due to DM (CC + MLO) and DBT (CC + MLO) examinations in Brazil, ranging from 20.

View Article and Find Full Text PDF

Granites are widely used in construction and they may be potential sources of ionizing radiation, due to the presence of radionuclides such as Kand decay products from Useries and Thseries. These radionuclides occur in the minerals constituting the rocks. To evaluate the doses in humans exposed to K, and decay products from Useries and Thseries γ radiation, a room with dimensions of 4.

View Article and Find Full Text PDF

In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes.

View Article and Find Full Text PDF

Parkinson's disease (PD) presents several motor signs, including tremor and bradykinesia. However, these signs can also be found in other motor disorders and in neurologically healthy older adults. The incidence of bradykinesia in PD is relatively high in all stages of the disorder, even when compared to tremor.

View Article and Find Full Text PDF

In this work we investigated the way in which conversion coefficients from air kerma-area product for effective doses (CCE) and entrance skin doses (CCESD) in interventional radiology (IR) are affected by variations in the filtration, projection angle of the X-ray beam, lead curtain attached to the surgical table, and suspended shield lead glass in regular conditions of medical practice. Computer simulations were used to model an exposure scenario similar to a real IR room. The patient and the physician were represented by MASH virtual anthropomorphic phantoms, inserted in the MCNPX 2.

View Article and Find Full Text PDF

Using ultrasound images to track large tissue deformations usually requires breaking up the deformation into steps and then summing the resulting displacement estimates. The accumulated displacement estimation error therefore depends not only on the error in each step but also on the statistical relationships between estimation steps. These relationships have not been thoroughly studied.

View Article and Find Full Text PDF

In this work the peak kilovoltage (kVp), practical peak voltage (PPV) and air kerma rate were measured with the noninvasive meters Radcal Accu-kV® Diagnostic Sensor™ model 40×12-W, and PTW Diavolt. The results were compared in order to ensure the quality control, compare the meters and establish the new quantity PPV, at the Calibration Laboratory of IPEN. These tests were performed using the standard diagnostic radiology quality beam RQR5, and the results are in good agreement.

View Article and Find Full Text PDF

The extrapolation chamber is a parallel-plate ionization chamber that allows variation of its air-cavity volume. In this work, an experimental study and MCNP-4C Monte Carlo code simulations of an ionization chamber designed and constructed at the Calibration Laboratory at IPEN to be used as a secondary dosimetry standard for low-energy X-rays are reported. The results obtained were within the international recommendations, and the simulations showed that the components of the extrapolation chamber may influence its response up to 11.

View Article and Find Full Text PDF

A homemade cylindrical ionization chamber was studied for routine use in therapy beams of (60)Co and X-rays. Several characterization tests were performed: leakage current, saturation, ion collection efficiency, polarity effect, stability, stabilization time, chamber orientation and energy dependence. All results obtained were within international recommendations.

View Article and Find Full Text PDF

A pencil-type ionization chamber, developed at Instituto de Pesquisas Energéticas e Nucleares (IPEN), was characterized with the objective to verify the possibility of its application in radiation field mapping procedures. The characterization tests were evaluated, and the results were satisfactory. The results obtained for the X radiation field mapping with the homemade chamber were compared with those of a PTW Farmer-type chamber (TN 30011-1).

View Article and Find Full Text PDF

This work provides an detailed analysis of a method for ultrasound-based elasticity image formation using dynamic compression technique. Radiofrequency (RF) data acquired from a homogenous phantom, where both mechanical and acoustic proprieties were set equivalent to biologic tissues, were used to validate our results. Local strains were obtained by speckle tracking of the acoustic scatterers motion between a pair of RF echo fields acquired when the phantom was dynamically deformed at low frequency (approximately 1 Hz).

View Article and Find Full Text PDF