Publications by authors named "Lucas J Koerner"

The cut-open oocyte Vaseline gap technique is a powerful electrophysiological method for the characterization of ion channels. However, traditional amplifiers for cut-open oocyte Vaseline gap are labor intensive and require significant user expertise. We introduce an innovative, open-source digital amplifier system with high-speed digitization and software-controlled electronics for computer-driven automation.

View Article and Find Full Text PDF

Electrical sensing and stimulation of nervous system activity is a valuable tool to investigate neural activity both in vivo and in vitro. A general system capable of supporting users across a variety of use cases would be valuable for the field of neuroscience. We propose a new system capable of supporting a variety of experimental cases including low and high impedance electrodes with stimulation amplitudes up to multiple mA.

View Article and Find Full Text PDF

We demonstrate a methodology for non-contact classification of five different plastic types using an inexpensive direct time-of-flight (ToF) sensor, the AMS TMF8801, designed for consumer electronics. The direct ToF sensor measures the time for a brief pulse of light to return from the material with the intensity change and spatial and temporal spread of the returned light conveying information on the optical properties of the material. We use measured ToF histogram data of all five plastics, captured at a range of sensor to material distances, to train a classifier that achieves 96% accuracy on a test dataset.

View Article and Find Full Text PDF

We describe a custom and open source field-programmable gate array (FPGA)-based data acquisition (DAQ) system developed for electrophysiology and generally useful for closed-loop feedback experiments. FPGA acquisition and processing are combined with high-speed analog and digital converters to enable real-time feedback. The digital approach eases experimental setup and repeatability by allowing for system identification and in situ tuning of filter bandwidths.

View Article and Find Full Text PDF

Structure determination of proteins and other macromolecules has historically required the growth of high-quality crystals sufficiently large to diffract x-rays efficiently while withstanding radiation damage. We applied serial femtosecond crystallography (SFX) using an x-ray free-electron laser (XFEL) to obtain high-resolution structural information from microcrystals (less than 1 micrometer by 1 micrometer by 3 micrometers) of the well-characterized model protein lysozyme. The agreement with synchrotron data demonstrates the immediate relevance of SFX for analyzing the structure of the large group of difficult-to-crystallize molecules.

View Article and Find Full Text PDF

The production of high-performance carbon nanotube (CNT) materials demands understanding of the growth behavior of individual CNTs as well as collective effects among CNTs. We demonstrate the first use of grazing incidence small-angle X-ray scattering to monitor in real time the synthesis of CNT films by chemical vapor deposition. We use a custom-built cold-wall reactor along with a high-speed pixel array detector resulting in a time resolution of 10 msec.

View Article and Find Full Text PDF

A pair of techniques have been developed for performing time-resolved X-ray microdiffraction on irreversible phase transformations. In one technique capillary optics are used to focus a high-flux broad-spectrum X-ray beam to a 60 µm spot size and a fast pixel array detector is used to achieve temporal resolution of 55 µs. In the second technique the X-rays are focused with Kirkpatrick-Baez mirrors to achieve a spatial resolution better than 10 µm and a fast shutter is used to provide temporal resolution better than 20 µs while recording the diffraction pattern on a (relatively slow) X-ray CCD camera.

View Article and Find Full Text PDF

Dynamic X-ray studies can reach temporal resolutions limited by only the X-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successive pulses.

View Article and Find Full Text PDF

Solution small-angle X-ray scattering (SAXS) measurements were obtained using a 128 × 128 pixel X-ray mixed-mode pixel array detector (MMPAD) with an 860 µs readout time. The MMPAD offers advantages for SAXS experiments: a pixel full-well of >2 × 10(7) 10 keV X-rays, a maximum flux rate of 10(8) X-rays pixel(-1) s(-1), and a sub-pixel point-spread function. Data from the MMPAD were quantitatively compared with data from a charge-coupled device (CCD) fiber-optically coupled to a phosphor screen.

View Article and Find Full Text PDF