Background: Existing data on the impact of sex differences on transvenous lead extraction (TLE) outcomes in cardiac device patients are limited.
Objective: The purpose of this study was to evaluate the safety and efficacy of mechanical TLE in female patients.
Methods: A retrospective evaluation was performed on 3051 TLE patients (group 1: female; group 2: male) from a single tertiary referral center.
Introduction: Transcatheter atrial fibrillation (AF) ablation is still carried out with continuous invasive radial arterial blood pressure (IBP) monitoring in many centers. Continuous noninvasive blood pressure (CNBP) measurement using the volume-clamp method is a noninvasive alternative method used in ICU. No data on CNBP reliability are available in the electrophysiology lab during AF ablation, where rhythm variations are common.
View Article and Find Full Text PDFA 63-year-old man with hypertension and 3-vessel coronary artery disease previously treated with coronary artery bypass graft was admitted to our emergency room complaining of chest pain. He had undergone pacemaker implant 5 months before due to paroxysmal advanced atrioventricular block. Electrocardiography and troponin testing were unremarkable.
View Article and Find Full Text PDFPurpose: The aim of the study was to compare the long-term clinical and electrical performance of Micra leadless pacemaker with transvenous single-chamber pacemaker (TV-VVI PM) in a high-volume centre for transvenous lead extraction (TLE).
Methods: One-hundred patients (group 1) undergoing Micra implant were matched with 100 patients undergoing TV-VVI PM implant (group 2) by age, sex, left ventricular systolic ejection fraction and previous TLE.
Results: The implant procedure was successful in all patients.
Aims: Optimal management of redundant or malfunctioning leads is controversial. We aimed to assess safety and efficacy of mechanical transvenous lead extraction (TLE) in patients with abandoned leads.
Methods And Results: Consecutive TLE procedures performed in our centre from January 2009 to December 2017 were considered.
Int J Cardiovasc Imaging
September 2020
To evaluate predictors of zero-X ray procedures for supraventricular arrhythmias (SVT) using minimally fluoroscopic approach (MFA). Patients referred for RF catheter ablation of SVT were admitted for a MFA with an electro-anatomical navigation system or a conventional fluoroscopic approach (ConvA). Exclusion criterion was the need to perform a transseptal puncture.
View Article and Find Full Text PDFBackground: Cardiac computed tomography (CT) is commonly used to study left atrial (LA) and pulmonary veins (PVs) anatomy before atrial fibrillation (AF) ablation. The aim of the study was to determine the impact of pre-procedural cardiac CT with 3D reconstruction on procedural outcomes and radiological exposure in patients who underwent radiofrequency catheter ablation (RFA) of AF.
Methods: In this registry, 493 consecutive patients (age 62 ± 8 years, 70% male) with paroxysmal (316) or persistent (177) AF who underwent first procedure of RFA were included.
Aims: We aimed at investigating the feasibility and outcome of Micra implant in patients who have previously undergone transvenous lead extraction (TLE), in comparison to naïve patients implanted with the same device.
Methods And Results: Eighty-three patients (65 males, 78.31%; 77.
Expert Rev Cardiovasc Ther
October 2018
Increasing device implantations, patient comorbidities, and longer life expectancy contribute to an increased need for lead extraction. Even if transvenous lead extraction (TLE) is a highly successful procedure, some serious procedural complications are reported. In order to identify those patients who are at higher risk, risk stratification scores were proposed.
View Article and Find Full Text PDFAims: To demonstrate the feasibility and long-term performances of a non-apical Micra pacemaker implantation.
Methods And Results: Fifty-two consecutive patients underwent Micra implantation, targeting a non-apical site of delivery when feasible. Each patient received a regular follow-up (mean 13 ± 9 months).
The implantable cardioverter defibrillator (ICD) is today an indisputable evidence-based treatment for cardiac sudden death both in primary and secondary prevention. However many clinical conditions that would represent an indication to ICD implantation, according to guidelines, may be potentially reversible or may be accompanied by temporary contraindications to the implant. Moreover transvenous cardioverter defibrillator implantation still carries a not negligible risk of complications both acutely and at follow-up.
View Article and Find Full Text PDFThe implantation rate of cardiac implantable electronic devices has consistently increased in the last 20 years, as have the related complication rates. The most relevant issue is the removal of pacing and implantable cardioverter defibrillator (ICD) leads, which a few months after implantation tend to develop intravascular fibrosis, often making extraction a challenging and risky procedure. Areas covered: The transvenous lead extraction (TLE) scenario is constantly evolving.
View Article and Find Full Text PDFIntroduction: Transvenous lead extraction (TLE) is the gold standard for lead removal. The increasing rate of cardiac implantable electronic device (CIED) implantations and of CIED related complications highlight the importance of transvenous lead extraction .
Areas Covered: The TLE scenario is constantly changing.
Sustained ventricular tachyarrhythmias represent a kind of complication shared by a number of clinical presentations of heart disease, sometimes leading to sudden cardiac death. Many efforts have been made in the fight against such a complication, mainly being represented by the implantable cardioverter defibrillator (ICD). In recent years, catheter ablation has grown as a means to effectively treat patients with sustained ventricular arrhythmias, in the contest of different cardiac substrates.
View Article and Find Full Text PDFBackground: Riata (RT) and Sprint Fidelis (SF) leads were recalled by the United States Food and Drug Administration because of an increased rate of failure mainly due to conductor fracture or insulation abrasion. According to lead design and type of failure, extraction complexity may be different, potentially affecting procedural outcomes and indications.
Objective: The purpose of this study was to assess the extraction profile of RT leads with and without cable externalization in comparison to SF leads.
The implantable cardioverter defibrillator is today an indisputable evidence-based treatment for cardiac sudden death both in primary and secondary prevention. However, trans-venous cardioverter defibrillator implantation still carries a not negligible risk of complications both acutely and during follow-up. Trans-venous endocardial lead is the weak link of implantable cardioverter defibrillator (ICD) technology being the source of most mechanical complications on vessels and heart structures and exposed to infection, malfunction and recalls.
View Article and Find Full Text PDFBackground: Percutaneous removal of implantable cardioverter-defibrillator (ICD) leads is a difficult procedure because of the consequence of massive fibrous tissue growth along the lead.
Objective: The purpose of this study was to describe the occurrence and location of fibrous adherences in ICD lead extraction and to identify potential predictors among patient and lead characteristics.
Methods: We studied 637 consecutive patients who underwent transvenous extraction of 678 ICD leads from 1997 to 2013.
Aims: We report our 15 years experience of a mechanical single-sheath technique with a multiple venous entry-site approach. We evaluated the effectiveness and safety of this technique in implantable defibrillator (ICD) lead extraction and investigated the potential association between clinical and lead-related factors and procedural complexity.
Methods And Results: The proposed technique consists of an initial attempt at manual traction, followed by mechanical dilatation performed through the venous entry-site and, if necessary, by crossover to the internal transjugular approach.
Recent publications have identified a different epidemiological prevalence related to sex in some of the most common supraventricular and ventricular arrhythmias. This fact is attributed to the effect of sex hormones on myocardial cell electrophysiology. Women, in particular, have a higher prevalence than males with regard to intranodal reentrant tachycardia, idiopathic monomorphic ventricular tachycardia and ventricular arrhythmias in congenital or acquired long QT syndrome.
View Article and Find Full Text PDFBackground: The aim of this study was to evaluate procedural outcomes of coronary sinus (CS) lead extraction, focusing on predictors and need for mechanical dilatation (MD) in the event that manual traction (MT) is ineffective.
Methods: The study assessed results in 145 consecutive patients (age 69 ± 10 years; 121 men)--a total of 147 CS pacing leads--who underwent transvenous CS lead removal between January 2000 and March 2010.
Results: All leads but one (99%) (implantation time 29 ± 25 months) were successfully removed.
Aims: Few data are available on cardiac resynchronization therapy (CRT) after coronary sinus (CS) lead extraction. We aimed to evaluate the feasibility and mid-term outcome of transvenous CS lead reimplantation in a tertiary referral centre.
Methods And Results: We enrolled all patients who were referred to our hospital for CS lead removal from December 2000 through to May 2009 and were transvenously reimplanted with a CRT system before June 2009.
Background: In the Endotak Reliance G defibrillating leads (Guidant Corporation, St. Paul, MN, USA), coils are covered with expanded polytetrafluoroethylene (ePTFE) to prevent tissue ingrowth. The aim of the study was to evaluate transvenous extraction performance, outcomes, and fibrotic adherences rate of ePTFE defibrillating leads in comparison to traditional non-ePTFE cardiac defibrillator (ICD) leads.
View Article and Find Full Text PDF