Background: Transcatheter aortic valve replacement (TAVR)-in-TAVR within index supra-annular transcatheter heart valves (THVs) and high-risk anatomy can compromise coronary perfusion and re-access.
Case Summary: An 80-year-old male presented with acute heart failure caused by degeneration of an Evolut R THV, leading to severe aortic regurgitation. Aortic computed tomography imaging revealed a high-risk anatomy characterized by the index THV's commissural plane being placed above the coronary ostia and a valve-to-aorta distance of less than 2 mm, resulting not eligible for redo-TAVR according to recent literature.
Background: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) disease is still burdened by a non-negligible rate of stroke and permanent pacemaker implantation (PPI). These suboptimal results, possibly related to the unique BAV anatomy, might suggest the use of a different sizing method in this setting. The aim of our study is to evaluate whether the application of the supra-annular LIRA method might improve clinical outcomes in this population.
View Article and Find Full Text PDFRecently, an increase in the number of patients with severe aortic stenosis eligible for transcatheter aortic valve implantation (TAVI) has been observed worldwide. In order to reduce waiting lists, provide to all patients referred to us equal access to care and to further improve the collaboration with spoke centers, we developed a specific Hub & Spoke specific protocol for TAVI. According to our protocol, a clinical selection (with echo and computed tomography scan) is done by Spoke centers, the case is discussed with a multidisciplinary team online and the procedure is planned (access, valve type size).
View Article and Find Full Text PDFThe two surgical options for mitral valve regurgitation are replacement and repair, with annuloplasty being the cornerstone of correction. In cases of repair failure, especially in high surgical risk patients, transcatheter mitral valve-in-ring (MViR) procedures represent emerging and challenging options. Among the several complications linked to this treatment, this paper delves into the role that native mitral leaflets may play in precipitating acute bioprosthesis dysfunction in the MViR procedure.
View Article and Find Full Text PDFMitral stenosis (MS) poses significant challenges in diagnosis and management due to its varied etiologies, such as rheumatic mitral stenosis (RMS) and degenerative mitral stenosis (DMS). While rheumatic fever-induced RMS has declined in prevalence, DMS is rising with aging populations and comorbidities. Starting from a complex clinical case of DMS, the aim of this paper is to review the literature on mitral stenosis by analyzing the available tools and the differences in terms of diagnosis and treatment for rheumatic and degenerative stenosis.
View Article and Find Full Text PDFPatent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO.
View Article and Find Full Text PDFValve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.
View Article and Find Full Text PDFBackground: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances.
Aims: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI).
Methods: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI.
Catheter Cardiovasc Interv
September 2023
Catheter Cardiovasc Interv
September 2023
Intracoronary calcium embolization during percutaneous procedure is a very rare and unpredictable event, that can lead to serious complications and even expert operators could face some technical issues to solve it. This case report presents a technique called "block and crack" used to manage iatrogenic intracoronary calcium embolization of left anterior descending coronary artery. The technique involves implanting a drug eluting stent (DES) to block the embolus against the vessel wall, followed by the use of lithotripsy balloon inflated inside the DES to crack the calcium and achieve a better stent expansion.
View Article and Find Full Text PDFUnlabelled: Hemoglobin (Hb) levels have emerged as a useful tool for risk stratification and the prediction of outcome after myocardial infarction. We aimed at evaluating the prognostic impact of this parameter among patients in advanced age, where the larger prevalence of anemia and the higher rate of comorbidities could directly impact on the cardiovascular risk.
Methods: All the patients in the ELDERLY-2 trial, were included in this analysis and stratified according to the values of hemoglobin at admission.
Aims: The aim of this study was to minimize the procedure, and reduce the length of hospital stay (LoS) is the future objective for transcatheter aortic valve replacement (TAVI).Aims of the study are to identify procedural and electrocardiographical predictors of fast-track discharge in patients who underwent TAVI.
Methods: Patients treated with TAVI included in the One Hospital ClinicalService project were categorized according to the LoS.
Background: prior statin treatment has been shown to have favourable effects on short- and long-term prognosis in patients with acute coronary syndrome (ACS). There are limited data in older patients. The aim of this study was to investigate the association of previous statin therapy and presentation characteristics, infarct size and clinical outcome in older patients, with or without atherosclerotic cardiovascular disease (ASCVD), included in the Elderly-ACS 2 trial.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are generally younger and have a long life expectancy. Therefore, transcatheter bioprostheses durability appears of critical importance. Aim of the present study is to evaluate mid-term outcomes of TAVI in a high-volume single center cohort.
View Article and Find Full Text PDFRecent evidence has shown that transcatheter heart valve (THV) anchoring in bicuspid aortic valve (BAV) patients occurs at the level of the raphe, known as the LIRA (Level of Implantation at the RAphe) plane. Our previous work in a cohort of 20 patients has shown that the delineation of the perimeter and device sizing at this level is associated with optimal procedural outcome. The goals of this study were to confirm the feasibility of this method, evaluate 30-day outcomes of LIRA sizing in a larger cohort of patients, assess interobserver variation and reproducibility of this sizing methodology, and analyse the interaction of LIRA-sized prostheses with the surrounding anatomy.
View Article and Find Full Text PDFBackground: TAVR is a safe alternative to surgical aortic valve replacement (SAVR); however, sex-related differences are still debated. This research aimed to examine gender differences in a real-world transcatheter aortic valve replacement (TAVR) cohort.
Methods: All-comer aortic stenosis (AS) patients undergoing TAVR with a Medtronic valve across 19 Italian sites were prospectively included in the Italian Clinical Service Project (NCT01007474) between 2007 and 2019.