Introduction: Implant-supported removable complete overdentures (IODs) are a common treatment in case of edentulism and malfunctioning of the conventional denture. Manufacturing IODs in a conventional way (C-IODs) is time-consuming, but in a digital workflow, this can be done in three sessions. Digitally produced IODs (3D-IODs) are also more advantageous than C-IODs because lost or broken 3D-IODs can be swiftly reproduced as the digital design is always available.
View Article and Find Full Text PDFThe conventional treatment for distal radius fractures typically involves immobilization of the injured extremity using a conventional forearm cast. These casts do cause all sorts of discomfort during wear and impose life-style restrictions on the wearer. Personalized 3D printed splints, designed using three-dimensional (3D) imaging systems, might overcome these problems.
View Article and Find Full Text PDFBackground: Pudendal neuralgia (PN) is a chronic neuropathy that causes pain, numbness, and dysfunction in the pelvic region. The current state-of-the-art treatment is pulsed radiofrequency (PRF) in which a needle is supposed to be placed close to the pudendal nerve for neuromodulation. Given the effective range of PRF of 5 mm, the accuracy of needle placement is important.
View Article and Find Full Text PDFIntroduction And Hypothesis: The objective was to compare the location and motion of pessaries between women with pelvic organ prolapse (POP) with a successful (fitting) and unsuccessful (non-fitting) pessary treatment on dynamic magnetic resonance imaging (dMRI).
Methods: A cross-sectional exploratory study of 15 women who underwent a mid-sagittal dMRI of the pelvic floor at rest, during contraction and during Valsalva with three different types of pessaries. The coordinates of the pessaries cross section, inferior pubic point (IPP) and sacrococcygeal junction (SCJ) were obtained and the location (position, orientation) and the motion (translation and rotation) were calculated.
Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources.
View Article and Find Full Text PDFBackground: Currently, assessment of acetabular fracture reduction is mainly performed by evaluating 2D slices of 3D CT scans. This subjective method can potentially be improved by using 3D models and objective analysis tools. In order to evaluate the potential value of digital 3D reconstructed models in the assessment of acetabular fracture reduction, 3D reconstructions of the fractured acetabulum were compared to the mirrored healthy contralateral side for both the pre-, and post-surgical setting.
View Article and Find Full Text PDFFractures of the superior pubic ramus can be treated with screw insertion into the osseous fixation pathway (OFP) of the anterior column (AC). The entry point determines whether the screw exits the OFP prematurely. This can be harmful when it enters the hip joint or damages soft tissues inside the lesser pelvis.
View Article and Find Full Text PDF(1) Background: For years, Cone-Beam Computed Tomography’s (CBCT) have been the golden standard to evaluate implant placement accuracy. By validating Intraoral Scans (IOS) as an alternative to determine implant placement accuracy, a second CBCT could be avoided. (2) Methods: Using dynamic guided implant surgery, 23 implants were placed in 16 partially edentate patients.
View Article and Find Full Text PDFPurpose: To prove that a fully digital workflow, even for registration of the maxillomandibular relationship, can be employed to produce implant-supported overdentures and demonstrate that CAD/CAM techniques can be used to mill permanent implant-supported overdentures from polymethylmethacrylate discs, using polyetheretherketone as the sliding mechanism.
Materials And Methods: An edentulous 64-year-old woman received six implants in the maxilla after a bone augmentation procedure and two implants in the mandible. Five months after implant placement, intraoral scans were taken of her original complete dentures, of each prosthesis individually, and of both in centric relation, and another was taken of both edentulous arches, including the scan bodies.
Background: Flapless immediate implant placement and provisionalization (FIIPP) in the aesthetic zone is still controversial. Especially, an initial buccal crest thickness (BCT) of ≤1 mm is thought to be disruptive for the final buccal crest stability jeopardizing the aesthetic outcome.
Purpose: To radiographically assess the BCT and buccal crest height (BCH) after 1 year and to calculate the correlation between initial and final achieved BCT.
Proc Inst Mech Eng H
March 2022
Measurement and production of traditional prosthetic sockets are time-consuming, labor-intensive, and highly dependent on the personnel involved. An alternative way to make prostheses is using computer-aided design (CAD) and computer-aided manufacturing (CAM). Fused Filament Fabrication (FFF) may be an alternative to make low-cost prosthetic sockets.
View Article and Find Full Text PDFObjective: To identify clinical features and investigate treatment outcomes of patients with idiopathic pain related to a percutaneous bone-anchored hearing implant (BAHI) and to propose management recommendations.
Study Design: Retrospective chart analysis.
Setting: Tertiary referral center.
Eur J Trauma Emerg Surg
December 2021
Background: In patients with acetabular fractures, the reconstructed three-dimensional (3D) model of the contralateral acetabulum could be used as a mirrored template for the anatomical configuration of the affected joint. This has not been validated.
Objective: To investigate whether the right and left acetabula, as reconstructed 3D models, are valid mirrored duplicates that can be used as a reference model for the contralateral side.
Purpose: Not long after the introduction of osseointegrated implants outside the oral cavity, auricular prostheses are retrained on osseointegrated implants. New insights have been gained with the next-generation percutaneous osseointegrated titanium implants for bone conduction hearing since its introduction in 2010. As a result, the same technology was introduced in the Vistafix system (VXI implant) to retain auricular prostheses.
View Article and Find Full Text PDFThe implementation of augmented reality (AR) in image-guided surgery (IGS) can improve surgical interventions by presenting the image data directly on the patient at the correct position and in the actual orientation. This approach can resolve the switching focus problem, which occurs in conventional IGS systems when the surgeon has to look away from the operation field to consult the image data on a 2-dimensional screen. The Microsoft HoloLens, a head-mounted AR display, was combined with an optical navigation system to create an AR-based IGS system.
View Article and Find Full Text PDFAim: To assess the feasibility of a new method to augment the three-dimensional virtual skull model with a detailed surface model of the dentition produced by intra-oral scanning, compared to the conventional triple scan procedure.
Materials & Methods: In four patients who were planned for bimaxillary orthognathic surgery, the conventional triple scan procedure was carried out to create an augmented model. During scanning the patient wears a modified wax bite containing radio-opaque markers.
Purpose: The purpose of the study is to determine the clinically relevant accuracy of implant placement in the edentulous maxilla using computer planning and a mucosa-supported surgical template.
Materials And Methods: In each of in total 30 consecutive edentulous patients suffering from retention problems of their upper denture, two or four Brånemark MkIII Groovy (Nobel Biocare®, Zürich, Switzerland) implants in the maxilla were installed. Preoperatively, first, a cone-beam computer tomography (cone beam computer tomography) scan was acquired, followed by virtual implant planning.
Objectives: A novel, 3D technique to measure the differences in tooth crown morphology between the MSX1 cases and non-affected controls was designed to get a better understanding of dental phenotype-genotype associations.
Materials And Methods: Eight Dutch subjects from a single family with tooth agenesis, all with an established nonsense mutation c.332 C > A, p.
Clin Oral Implants Res
November 2013
Purpose: To design a relevant method to compare the virtual planned implant position to the ultimately achieved implant position and to evaluate, in case of discrepancy, the cause for this.
Materials And Methods: Five consecutive edentulous patients with retention problems of the upper denture received four implants in the maxilla. Preoperatively, first a cone-beam CT (CBCT) scan was acquired, followed by virtual implant planning.