Background: Short and rare episodes of atrial fibrillation (AF) are commonly detected using implanted devices (device-detected AF) in patients with prior stroke or transient ischemic attack (TIA). The effectiveness and safety of oral anticoagulation in patients with prior stroke or TIA and device-detected AF but with no ECG-documented AF is unclear.
Methods And Results: This prespecified analysis of the NOAH-AFNET 6 (Non-Vitamin K Antagonist Oral Anticoagulants in Patients With Atrial High Rate Episodes) trial with post hoc elements assessed the effect of oral anticoagulation in patients with device-detected AF with and without a prior stroke or TIA in the randomized, double-blind, double-dummy NOAH-AFNET 6 trial.
Background And Aims: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients.
Methods: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors.
Background: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known.
View Article and Find Full Text PDFAtrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences.
View Article and Find Full Text PDFFlecainide, similar to encainide and propafenone, is IC class antiarrhythmic, inhibiting Nav1.5 sodium channels in heart muscle cells and modulates cardiac conduction. Despite its over 40-year presence in clinical practice, strong evidence and well-known safety profile, flecainide distribution in Europe has not always been equal.
View Article and Find Full Text PDFAtrial fibrillation is the most commonly reported arrhythmia and, if undiagnosed or untreated, may lead to thromboembolic events. It is therefore desirable to provide screening to patients in order to detect atrial arrhythmias. Specific mobile apps and accessory devices, such as smartphones and smartwatches, may play a significant role in monitoring heart rhythm in populations at high risk of arrhythmia.
View Article and Find Full Text PDFBackground: Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death. ICD implantation decisions are currently based on reduced left ventricular ejection fraction (LVEF≤35%). However, in some patients, the non-arrhythmic death risk predominates thus diminishing ICD-therapy benefits.
View Article and Find Full Text PDFAims: The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter-Defibrillators (EU-CERT-ICD), a prospective investigator-initiated, controlled cohort study, was conducted in 44 centres and 15 European countries. It aimed to assess current clinical effectiveness of primary prevention ICD therapy.
Methods And Results: We recruited 2327 patients with ischaemic cardiomyopathy (ICM) or dilated cardiomyopathy (DCM) and guideline indications for prophylactic ICD implantation.
Background: Although cardiac resynchronisation therapy (CRT) is an important player in the treatment of patients with heart failure (HF), the proportion of CRT patients with no improvement in either echocardiographic or clinical parameters remains consistently high and accounts for about 30% despite meeting CRT implantation criteria. Furthermore, in patients suffering from HF, renal dysfunction accounts for as many as 30-60%. Accordingly, CRT may improve renal function inducing a systemic haemodynamic benefit leading to increased renal blood flow.
View Article and Find Full Text PDFPurpose: Eight-millimeter-tip ablation catheters are characterized by poor mapping resolution as they depend on electrode size and spacing. IntellaTip MiFi XP 8-mm (Boston Scientific) catheters offer high mapping resolution due to 3 mini-electrodes (ME) located at the distal tip of the catheter and are dedicated for cavo-tricuspid isthmus (CTI) radiofrequency ablation (RFA). The aim of the study was to evaluate the usefulness, effectiveness and safety of novel IntellaTip MiFi XP catheter for CTI RFA and its ability to localize anatomical structures of the heart.
View Article and Find Full Text PDFBackground: Validation data of the use of implantable cardioverter-defibrillators (ICD) in the pediatric population is insufficient, with limited follow-up periods.
Objectives: The aim of the study was to report on 17 years of experience with implantable cardioverter-defibrillator (ICD) therapy in children and young adults.
Material And Methods: This retrospective review included patients below the age of 18 years at the time of ICD implantation between May 2000 and December 2017.
Objective: Diabetes increases the risk of all-cause mortality and sudden cardiac death (SCD). The exact mechanisms leading to sudden death in diabetes are not well known. We compared the incidence of appropriate shocks and mortality in patients with versus without diabetes with a prophylactic implantable cardioverter defibrillator (ICD) included in the retrospective EU-CERT-ICD registry.
View Article and Find Full Text PDFBackground: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue.
View Article and Find Full Text PDFBackground: A small proportion of patients undergoing primary prophylactic implantation of implantable cardioverter defibrillators (ICDs) experiences malignant arrhythmias. We postulated that periodic repolarisation dynamics, a novel marker of sympathetic-activity-associated repolarisation instability, could be used to identify electrically vulnerable patients who would benefit from prophylactic implantation of ICDs by way of a reduction in mortality.
Methods: We did a prespecified substudy of EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD), a prospective, investigator-initiated, non-randomised, controlled cohort study done at 44 centres in 15 EU countries.
Self-terminating atrial arrhythmias are commonly detected on continuous rhythm monitoring, e.g. by pacemakers or defibrillators.
View Article and Find Full Text PDFBackground: Cardiac resynchronization therapy (CRT) is a valuable intracardiac device--based treatment option for a subgroup of patients with advanced heart failure (HF) and QRS prolongation. However, still a significant proportion of patients do not benefit from CRT implantation, labeled as non-responders.
Objectives: The aim of the present study was to evaluate the N-terminal prohormone of brain natriuretic peptide (NT-pro BNP) and high sensitivity troponin T (cTnThs) value as predictors of CRT response in a 12-month observation.
BACKGROUND Catheter radiofrequency ablation for typical atrial flutter is considered to be safe and effective. However, atrial fibrillation (AF) following cavotricuspid isthmus ablation for atrial flutter has been reported in patients without a previous history of AF, which has implications for the decision to use oral anticoagulation. This retrospective study at a single center aimed to evaluate the occurrence of AF in patients after successful cavotricuspid isthmus ablation of typical atrial flutter and to determine the incidence and associations with AF during follow-up.
View Article and Find Full Text PDFAims: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value.
Methods And Results: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries.