Background: The StatSensor® Xpress-i™, a point-of-care system for blood creatinine measurement, offers patients the possibility of self-monitoring creatinine. In this study, the analytical performance of the StatSensor® for both detecting current renal function and monitoring renal (dys)function in kidney transplant patients was examined.
Methods: Accuracy of the StatSensor® with capillary and venous whole blood was evaluated and compared to an isotopic dilution mass spectrometry (IDMS)-traceable enzymatic creatinine test in venous serum (n=138).
Background: A multicenter study conducted in Southeast Asia to derive reference intervals (RIs) for 72 commonly measured analytes (general chemistry, inflammatory markers, hormones, etc.) featured centralized measurement to clearly detect regionality in test results. The results of 31 standardized analytes are reported, with the remaining analytes presented in the next report.
View Article and Find Full Text PDFWe describe an External Quality Assessment Scheme (EQAS) intended for reference (calibration) laboratories in laboratory medicine and supervised by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine and the responsible Committee on Traceability in Laboratory Medicine. The official EQAS website, RELA (www.dgkl-rfb.
View Article and Find Full Text PDFClin Chem Lab Med
May 2013
The concept of measurement traceability provides the most important strategy in achieving standardization in laboratory medicine aimed at equivalent measurement results regardless of the principle of measurement, the method, the actual measurement procedure (test kit) and the laboratory where analyses are carried out.
View Article and Find Full Text PDFBirth Defects Res A Clin Mol Teratol
February 2009
Background: The bladder exstrophy-epispadias complex represents a spectrum of urogenital anomalies in which part or all of the distal urinary tract fail to close and are exposed on the outer abdominal wall. Previous studies are suggestive of an underlying multifactorial mode of inheritance. However, no genetic or nongenetic factor has been identified so far.
View Article and Find Full Text PDFContext: Harmonization and standardization of results among different clinical laboratories is necessary for clinical practice guidelines to be established.
Objective: To evaluate the state of the art in measuring 10 routine chemistry analytes.
Design: A specimen prepared as off-the-clot pooled sera and 4 conventionally prepared specimens were sent to participants in the College of American Pathologists Chemistry Survey.
Clin Biochem Rev
November 2007
In addition to reference measurement procedures and reference materials, reference or calibration laboratories play an integral role in the implementation of measurement traceability in routine laboratories. They provide results of measurements using higher-order methods, e.g.
View Article and Find Full Text PDFClin Chem Lab Med
November 2006
This paper is the eighth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2.
View Article and Find Full Text PDFBackground: Diagnostic manufacturers must ensure/document metrologically traceable assays. We report on a feasibility study of a split-sample comparison for that purpose. Processed, frozen single-donation sera, assigned target values by candidate reference measurement procedures (cRMPs), were used with immunoassays for total thyroxine (TT(4)) and triiodothyronine (TT(3)) as models.
View Article and Find Full Text PDFContext: The National Kidney Disease Education Program recommends calculating glomerular filtration rate from serum creatinine concentration. Accurate creatinine measurements are necessary for this calculation.
Objective: To evaluate the state of the art in measuring serum creatinine, as well as the ability of a proficiency testing program to measure bias for individual laboratories and method peer groups.
Background: Assuring/demonstrating metrologic traceability of in vitro diagnostics necessitates the availability of measurand-specific reference measurement systems (RMSs) and the possibility for industry to work with competent reference measurement laboratories (RMLs). Here we report the results of a European project to investigate the feasibility of developing a RMS for serum total thyroxine.
Methods: Four candidate RMLs (cRMLs) developed/implemented variants of a candidate reference measurement procedure (cRMP) based on isotope dilution-liquid chromatography-mass spectrometry.
Dehydroepiandrosterone (DHEA) and its sulfate (DHEAS) are suggested to be important neurosteroids. We investigated steroid sulfatase (STS) in human temporal lobe biopsies in the context of possible cerebral DHEA(S) de novo biosynthesis. Formation of DHEA(S) in mature human brain tissue has not yet been studied.
View Article and Find Full Text PDFEstrogens play a crucial role in multiple functions of the brain and the proper balance of inactive estrone and active estradiol-17beta might be very important for their cerebral effects. The interconversion of estrone and estradiol-17beta in target tissues is known to be catalysed by a number of human 17beta-hydroxysteroid dehydrogenase (17beta-HSD) isoforms. The present study shows that enzyme catalysed interconversion of estrone and estradiol-17beta occurs in the human temporal lobe.
View Article and Find Full Text PDFDehydroepiandrosterone and its sulphate are important factors for vitality, development and functions of the CNS. They were found to be subjects to a series of enzyme-mediated conversions within the rodent CNS. In the present study, we were able to demonstrate for the first time that membrane-associated dehydroepiandrosterone 7alpha-hydroxylase activity occurs within the human brain.
View Article and Find Full Text PDFThis paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2.
View Article and Find Full Text PDFThis paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2.
View Article and Find Full Text PDFThis paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2.
View Article and Find Full Text PDFThis paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2.
View Article and Find Full Text PDFClin Chem Lab Med
June 2002
This paper is the third in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2.
View Article and Find Full Text PDFClin Chem Lab Med
June 2002
This paper is the second in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 3.
View Article and Find Full Text PDFThis paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and with the certification of reference preparations. Other parts deal with: Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3.
View Article and Find Full Text PDF