Breast cancer remains the most prevalent cancer among women worldwide, necessitating advancements in diagnostic methods. The integration of artificial intelligence (AI) into mammography has shown promise in enhancing diagnostic accuracy. However, understanding patient perspectives, particularly considering the psychological impact of breast cancer diagnoses, is crucial.
View Article and Find Full Text PDFContrast-enhanced mammography (CEM) is a relatively recent diagnostic technique increasingly being utilized in clinical practice. Until recently, there was a lack of standardized reporting for CEM findings. However, this has changed with the publication of a supplement in the Breast Imaging Reporting and Data System (BI-RADS).
View Article and Find Full Text PDFPurpose: This study aimed to investigate the use of contrast-free magnetic resonance imaging (MRI) as an innovative screening method for detecting breast cancer in high-risk asymptomatic women. Specifically, the researchers evaluated the diagnostic performance of diffusion-weighted imaging (DWI) in this population.
Methods: MR images from asymptomatic women, carriers of a germline mutation in either the BRCA1 or BRCA2 gene, collected in a single center from January 2019 to December 2021 were retrospectively evaluated.
Breast cancer is the most common forms of cancer and a leading cause of mortality in women. Early and correct diagnosis is, therefore, essential to save lives. The development of diagnostic imaging applied to the breast has been impressive in recent years and the most used diagnostic test in the world is mammography, a low-dose X-ray technique used for imaging the breast.
View Article and Find Full Text PDFRationale And Objectives: The new version of the Contrast Enhanced Mammography (CEM) Breast imaging Reporting and Data System (BIRADs) encourages investigations of a new enhancement descriptor: "Lesion Conspicuity" (LC). The study aims to assess the diagnostic performance and the relationship with the receptor profile of this new enhancement descriptor.
Materials And Methods: Three hundred twenty-five patients with 381 breast lesions who underwent CEM before histological assessmentwere selected.
The aim of this study was to evaluate the diagnostic performance of contrast-enhanced spectral mammography (CESM) in predicting breast lesion malignancy due to microcalcifications compared to lesions that present with other radiological findings. Three hundred and twenty-one patients with 377 breast lesions that underwent CESM and histological assessment were included. All the lesions were scored using a 4-point qualitative scale according to the degree of contrast enhancement at the CESM examination.
View Article and Find Full Text PDFWe aimed to investigate the association between the radiomic features of contrast-enhanced spectral mammography (CESM) images and a specific receptor pattern of breast neoplasms. In this single-center retrospective study, we selected patients with neoplastic breast lesions who underwent CESM before a biopsy and surgical assessment between January 2013 and February 2022. Radiomic analysis was performed on regions of interest selected from recombined CESM images.
View Article and Find Full Text PDFObjective: Although breast cancer screening can benefit from Artificial Intelligence (AI), it is still unknown whether, to which extent or under which conditions, the use of AI is going to be accepted by the general population. The aim of our study is to evaluate what the females who are eligible for breast cancer screening know about AI and how they perceive such innovation.
Methods: We used a prospective survey consisting of a 11-multiple-choice questionnaire evaluating statistical associations with Chi-Square-test or Fisher-exact-test.
Background: To create a predictive score of malignancy of a breast lesion based on the main contrast enhancement features ascertained by contrast-enhanced spectral mammography (CESM). Methods: In this single-centre prospective study, patients with suspicious breast lesions (BIRADS > 3) were enrolled between January 2013 and February 2022. All participants underwent CESM prior to breast biopsy, and eventually surgery.
View Article and Find Full Text PDFPurpose: To evaluate if a computer-aided diagnosis (CAD) system on ultrasound (US) can improve the diagnostic performance of inexperienced radiologists.
Methods: We collected ultrasound images of 256 breast lesions taken between March and May 2020. We asked two experienced and two inexperienced radiologists to retrospectively review the US features of each breast lesion according to the Breast Imaging Reporting and Data System (BI-RADS) categories.
Breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) is a rare and newly recognized subtype of T cell Non-Hodgkin Lymphoma (NHLs) associated with breast implants.The mechanism involved in the development of this kind of lymphoma is still uncertain.BIA-ALCL is generally an indolent disease localized to the breast implant and its capsule and effectively treated with capsulectomy alone without chemotherapy.
View Article and Find Full Text PDFIn the last few years, ultrasound-guided vacuum-assisted breast biopsy (US-VABB) has replaced surgical biopsy due to higher diagnostic accuracy and lower patient discomfort, and, at present, an even greater possibility is represented by the new wireless ultrasound-guided VAB device (Wi-UVAB). The purpose of our study is to determine the diagnostic accuracy of this new device in a sizeable representative number of patients. From January 2014 to June 2018, 168 biopsies were performed in our institution using the new Wi-UVAB device.
View Article and Find Full Text PDFIntroduction: Air-dried slide preparation for fine needle aspiration cytology procedures is currently considered unsafe because of the risk of infectious aerosols of coronavirus 19. This study compares the safety and accuracy of two different protocols, one with and one without air-dried slides.
Methods: Starting from 3 March 2020, we discontinued the use of air-dried slides during breast fine needle aspiration procedures.
Italy has one of the highest COVID-19 clinical burdens in the world and Lombardy region accounts for more than half of the deaths of the country. Since COVID-19 is a novel disease, early impactful decisions are often based on experience of referral centres.We report the re-organisation which our institute (IEO, European Institute of Oncology), a cancer referral centre in Lombardy, went through to make our breast-imaging division pandemic-proof.
View Article and Find Full Text PDFPurpose: To compare the efficacy of contrast-enhanced spectral mammography, with ultrasound, full field digital mammography and magnetic resonance imaging in detection and size estimation of histologically proven breast tumors.
Methods: This open-label, single center, prospective study, included 160 dense breast women with at least one suspicious mammary lesion evaluated by ultrasound, full field digital mammography and magnetic resonance imaging in whom a mammary tumor was histologically proven after surgery performed at the European Institute of Oncology between January 2013 and December 2015. Following the complete diagnostic procedure, the patients were further investigated by contrast-enhanced spectral mammography prior to surgery.
Objectives: To evaluate the underestimation rate and clinical relevance of lobular neoplasia in vacuum-assisted breast biopsy (VABB).
Methods: A total of 161 cases of LN were retrieved from 6,435 VABB. The histological diagnosis was ALH (atypical lobular hyperplasia) in 80 patients, LCIS (lobular carcinoma in situ) in 69 patients and PLCIS (pleomorphic lobular carcinoma in situ) in 12 patients.
Background: This retrospective study aims to determine: 1) the sensitivity of preoperative mammography (Mx) and ultrasound (US), and re-reviewed Mx to detect multifocal multicentric breast carcinoma (MMBC), defined by pathology on surgical specimens, and 2) to analyze the characteristics of both detected and undetected foci on Mx and US.
Methods: Three experienced breast radiologists re-reviewed, independently, digital mammography of 97 women with MMBC pathologically diagnosed on surgical specimens. The radiologists were informed of all neoplastic foci, and blinded to the original mammograms and US reports.
Purpose: Digital mammography is known to have lower spatial resolution compared to conventional analogic mammography. The aim of this study was to evaluate whether this physical feature could compromise the perception of microcalcifications in radiological findings.
Materials And Methods: Fifty-two surgical samples of non-palpable breast lesions with microcalcifications were imaged using both techniques.