Background Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening.
View Article and Find Full Text PDFPurpose: To determine the effect of tomosynthesis imaging as a function of age for breast cancer screening.
Methods: Screening performance metrics from 13 institutions were examined for 12 months prior to introduction of tomosynthesis (period 1) and compared to those after introduction of tomosynthesis (period 2, range 3-22 months). Screening metrics for women ages 40-49, 50-59, 60-69, and 70+ , included rates per 1000 screens for recalls, biopsies, cancers, and invasive cancers detected.
Rationale And Objectives: Our objective is to determine whether expected utility (EU) and the area under the receiver operator characteristic (AUC) are consistent with one another as endpoints of observer performance studies in mammography. These two measures characterize receiver operator characteristic performance somewhat differently. We compare these two study endpoints at the level of individual reader effects, statistical inference, and components of variance across readers and cases.
View Article and Find Full Text PDFAJR Am J Roentgenol
February 2014
Objective: The purpose of this study was to compare two methods of combining tomosynthesis with digital mammography by assessing diagnostic accuracy and recall rates for digital mammography alone and digital mammography combined with one-view tomosynthesis and two-view tomosynthesis.
Subjects And Methods: Three hundred ten cases including biopsy-proven malignancies (51), biopsy-proven benign findings (47), recalled screening cases (138), and negative screening cases (74) were reviewed by 15 radiologists sequentially using digital mammography, adding one-view tomosynthesis, and then two-view tomosynthesis. Cases were assessed for recall and assigned a BI-RADS score and probability of malignancy for each imaging method.
Purpose: To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial.
Materials And Methods: A prospective, reader- and modality-balanced screening study of participants undergoing combined mammography plus tomosynthesis, the results of which were read independently by four different radiologists, is under way. The study was approved by a regional ethics committee, and all participants provided written informed consent.
Radiology
January 2013
Purpose: To compare radiologists' diagnostic accuracy and recall rates for breast tomosynthesis combined with digital mammography versus digital mammography alone.
Materials And Methods: Institutional review board approval was obtained at each accruing institution. Participating women gave written informed consent.
Full-field digital mammography (FFDM) with soft-copy reading is more complex than screen-film mammography (SFM) with hard-copy reading. The aim of this study was to compare inter- and intraobserver variability in SFM versus FFDM of paired mammograms from a breast cancer screening program. Six radiologists interpreted mammograms of 232 cases obtained with both techniques, including 46 cancers, 88 benign lesions, and 98 normals.
View Article and Find Full Text PDFMammography is an effective imaging tool for detecting breast cancer at an early stage and is the only screening modality proved to reduce mortality from breast cancer. However, the overlap of tissues depicted on mammograms may create significant obstacles to the detection and diagnosis of abnormalities. Diagnostic testing initiated because of a questionable result at screening mammography frequently causes patients unnecessary anxiety and incurs increased medical costs.
View Article and Find Full Text PDFPurpose: To retrospectively compare screen-film and full-field digital mammography with soft-copy interpretation for reader performance in detection and classification of breast lesions in women in a screening program.
Materials And Methods: Regional ethics committee approved the study; signed patient consents were obtained. Two-view mammograms were obtained with digital and screen-film systems at previous screening studies.
A method is described for using a limited number (typically 10-50) of low-dose radiographs to reconstruct the three-dimensional (3D) distribution of x-ray attenuation in the breast. The method uses x-ray cone-beam imaging, an electronic digital detector, and constrained nonlinear iterative computational techniques. Images are reconstructed with high resolution in two dimensions and lower resolution in the third dimension.
View Article and Find Full Text PDFCurr Probl Diagn Radiol
August 2002
In the evaluation of asbestos-related pulmonary and pleural abnormalities, conventional chest radiography has been shown to have a low sensitivity for the detection of lung nodules and subtle interstitial disease. Pleural plaques may simulate pulmonary nodules, and interstitial processes can be masked by adjacent pleural abnormalities. Dual-energy digital subtraction chest radiography may enable investigators to characterize asbestos-related pulmonary and pleural abnormalities with greater accuracy.
View Article and Find Full Text PDF