Background: Cardiac resynchronization therapy (CRT) is indicated for patients with heart failure with reduced left ventricular ejection fraction (LVEF) and chronic right ventricular (RV) pacing burden ≥40% (pacing-induced cardiomyopathy, PICM). It is uncertain whether baseline RV pacing burden impacts response to CRT.
Methods: We conducted a retrospective study of all CRT upgrades for PICM at our hospital from January 2017 to December 2018.
Pacing Clin Electrophysiol
October 2021
Persistent left superior vena cava (PLSVC) poses technical challenges to implantation of transvenous cardiac implantable electronic devices. His-bundle pacing is a physiologic pacing strategy to avoid or treat pacing-induced cardiomyopathy. We report a case of His-bundle lead implantation in a patient with PLSVC, absent right SVC, and pacing-induced cardiomyopathy.
View Article and Find Full Text PDFBackground: The safety of perioperative anticoagulation (AC) and antiplatelet (AP) therapy with subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unknown. The purpose of this study was to identify the risk factors associated with hematoma complicating S-ICD implantation.
Methods: Records were retrospectively reviewed from 200 consecutive patients undergoing S-ICD implantation at two academic medical centers.
Atrioventricular node (AVN) ablation is an effective treatment for symptomatic patients with atrial arrhythmias who are refractory to rhythm and rate control strategies where optimal ventricular rate control is desired. There are limited data on the predictors of failure of AVN ablation. Our objective was to identify the predictors of failure of AVN ablation.
View Article and Find Full Text PDFInt J Cardiol
July 2015
Introduction: Limited data is available regarding the novel Reveal LinQ (LinQ) which is a new generation implantable loop recorders (ILRs).
Methods: We performed a prospective, observational study of all consecutive patients undergoing conventional (Reveal XT; XT) and LinQ devices at our institution between January 2012 and December 2014.
Results: A total of 217 patients underwent ILR implantation.
Pacing Clin Electrophysiol
February 2008
We report an unusual case of a 75-year-old male electrocuted by lightning strike rescued by implantable cardioverter defibrillator (ICD) shock coincidentally. Lightning strikes are an unusual cause of fatal cardiac arrhythmias. Depending on the amount of energy and the current vector affecting the heart, the arrhythmia burden ranges from asystole to ventricular fibrillation.
View Article and Find Full Text PDFObjectives: We sought to evaluate the influence of single- versus dual-chamber implantable cardioverter defibrillators (ICDs) on the occurrence of heart failure and mortality as well as appropriate and inappropriate ICD therapy in the Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II).
Background: In MADIT-II, ICD therapy in patients with a prior myocardial infarction and ejection fraction < or =0.30 was associated with a 31% reduction in risk of mortality when compared to conventionally treated patients.