Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding.

View Article and Find Full Text PDF

Human presence can affect indoor air quality because of secondary organic compounds formed upon reactions between gaseous oxidant species, , ozone (O), hydroxyl radicals (OH), and chemical compounds from skin, exhaled breath, hair and clothes. We assess the gas-phase product compounds generated by reactions of gaseous O with volatile organic compounds (VOCs) from exhaled human breath by real time analysis using a high-resolution quadrupole-orbitrap mass spectrometer (HRMS) coupled to a secondary electrospray ionization (SESI) source. Based on the product compounds identified we propose a reaction mechanism initiated by O oxidation of the most common breath constituents, isoprene, α-terpinene and ammonia (NH).

View Article and Find Full Text PDF

The primarily emitted compounds by human presence, e.g., skin and volatile organic compounds (VOCs) in breath, can react with typical indoor air oxidants, ozone (O), and hydroxyl radicals (OH), leading to secondary organic compounds.

View Article and Find Full Text PDF

Plasma density measurements are key to a wide variety of high-energy-density (HED) and laboratory astrophysics experiments. We present a creative application of photonic Doppler velocimetry (PDV) from which time- and spatially resolved electron density measurements can be made. PDV has been implemented for the first time in close proximity, ∼6 cm, to the high-intensity radiation flux produced by a z-pinch dynamic hohlraum on the Z-machine.

View Article and Find Full Text PDF

Methoxyphenols represent important pollutants that can participate in the formation of secondary organic aerosols (SOAs) through chemical reactions with atmospheric oxidants. In this study, we determine the influence of ionic strength, pH, and temperature on the heterogeneous reaction of NO with an aqueous film consisting of acetosyringone (ACS), as a proxy for methoxyphenols. The uptake coefficient of NO (50 ppb) on ACS (1 × 10 mol L) is γ = (9.

View Article and Find Full Text PDF

We report experimental and modeling results for the charge state distribution of laboratory photoionized neon plasmas in the first systematic study over nearly an order of magnitude range of ionization parameter ξ∝F/N_{e}. The range of ξ is achieved by flexibility in the experimental platform to adjust either the x-ray drive flux F at the sample or the electron number density N_{e} or both. Experimental measurements of photoionized plasma conditions over such a range of parameters enable a stringent test of atomic kinetics models used within codes that are applied to photoionized plasmas in the laboratory and astrophysics.

View Article and Find Full Text PDF

Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed.

View Article and Find Full Text PDF

Verification of physics models and computer simulations are heavily reliant upon the accuracy of experimental measurements. Calibration of instrument responses becomes an important step to achieve this goal. This paper presents systematic studies of bent potassium acid phthalate (KAP) crystals using Lawrence Berkeley National Laboratories, Advanced Light Source, beamline 9.

View Article and Find Full Text PDF

Emissions of secondary products through reactions of oxidants, ozone (O), and hydroxyl radical (·OH) with human skin lipids have become increasingly important in indoor environments. Here, we evaluate the secondary organic compounds formed through heterogeneous reactions of gaseous O with hand skin lipids by using a high-resolution quadrupole Orbitrap mass spectrometer coupled to a commercial secondary electrospray ionization (SESI) source. More than 600 ions were detected over a period of less than 40 min real-time measurements, among which 53 ions were characterized with a significant increasing trend in signal intensity at the presence of O.

View Article and Find Full Text PDF

Methoxyphenols are one of the most abundant classes of biomarker tracers for atmospheric wood smoke pollution. The reactions of atmospheric oxidants (ozone, OH) with methoxyphenols can contribute to the formation of secondary organic aerosols (SOA). Here, for the first time, we use the well-established vertical wetted wall flow tube (VWWFT) reactor to assess the effect of ionic strength (), pH, temperature, and ozone concentration on the reaction kinetics of ozone with acetosyringone (ACS), as a representative methoxyphenol compound.

View Article and Find Full Text PDF

Polycyclic aromatic hydrocarbons (PAHs) as constituents of urban grime and indoor surfaces can impact the photochemical conversion of nitrogen dioxide (NO) to nitrous acid (HONO) thereby impacting the oxidation capacity of the atmosphere. In this study we investigate the effect of relative humidity (RH%), light intensity, and NO concentrations on uptake coefficients (γ) of NO on solid film consisting of fluorene (FL) and a mixture of FL and NaSO as a proxy for urban and indoor grime at ambient pressure and temperature. γ(NO) on solid FL increased markedly from (5.

View Article and Find Full Text PDF

We discuss the experimental and modeling results for the x-ray heating and temperature of laboratory photoionized plasmas. A method is used to extract the electron temperature based on the analysis of transmission spectroscopy data that is independent of atomic kinetics modeling. The results emphasized the critical role of x-ray heating and radiation cooling in determining the energy balance of the plasma.

View Article and Find Full Text PDF

The hydroxyl radical (OH) is one of the most important oxidants controlling the oxidation capacity of the indoor atmosphere. One of the main OH sources indoors is the photolysis of nitrous acid (HONO). In this study, real-time measurements of HONO, nitrogen oxides (NOx) and ozone (O3) in an indoor environment in Guangzhou, China, were performed under two different conditions: (1) in the absence of any human activity and (2) in the presence of cooking.

View Article and Find Full Text PDF

The first systematic study of opacity dependence on atomic number at stellar interior temperatures is used to evaluate discrepancies between measured and modeled iron opacity [J. E. Bailey et al.

View Article and Find Full Text PDF

Acid phthalate crystals such as KAP crystals are a method of choice to record x-ray spectra in the soft x-ray regime ( ∼ 1 keV) using the large (001) 2 = 26.63 Å spacing. Reflection from many other planes is possible, and knowledge of the 2d spacing, reflectivity, and resolution for these reflections is necessary to evaluate whether they hinder or help the measurements.

View Article and Find Full Text PDF

A vertical wetted-wall flow-tube technique was used to explore the ionic strength effects at the air-water interface in mediating the sea-surface reaction between ozone (O) and pyruvic acid (PA). The uptake coefficients of ozone on aqueous PA increase substantially with the concentrations of bromide (Br) ions, clearly indicating that the dry deposition of ozone could be significantly enhanced due to the presence of carbonyl compounds such as PA at the bromide-rich sea surface. Based on the observed uptake coefficients, the estimated deposition velocity of ozone (100 ppb) for a nanomolar range of PA concentrations is ∼1 × 10 m s, which represents a significant contribution to the known deposition velocity of ozone at the sea surface.

View Article and Find Full Text PDF

Many experiments on Sandia National Laboratories' Z Pulsed Power Facility-a 30 MA, 100 ns rise-time, pulsed-power driver-use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He) or 6.151 keV (Mn He) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch.

View Article and Find Full Text PDF

The interpretation of x-ray spectra emerging from x-ray binaries and active galactic nuclei accreted plasmas relies on complex physical models for radiation generation and transport in photoionized plasmas. These models have not been sufficiently experimentally validated. We have developed a highly reproducible benchmark experiment to study spectrum formation from a photoionized silicon plasma in a regime comparable to astrophysical plasmas.

View Article and Find Full Text PDF

Iron opacity calculations presently disagree with measurements at an electron temperature of ∼180-195 eV and an electron density of (2-4)×10^{22}cm^{-3}, conditions similar to those at the base of the solar convection zone. The measurements use x rays to volumetrically heat a thin iron sample that is tamped with low-Z materials. The opacity is inferred from spectrally resolved x-ray transmission measurements.

View Article and Find Full Text PDF

Spherical-crystal microscopes are used as high-resolution imaging devices for monochromatic x-ray radiography or for imaging the source itself. Crystals and Miller indices (hkl) have to be matched such that the resulting lattice spacing d is close to half the spectral wavelength used for imaging, to fulfill the Bragg equation with a Bragg angle near 90 which reduces astigmatism. Only a few suitable crystal and spectral-line combinations have been identified for applications in the literature, suggesting that x-ray imaging using spherical crystals is constrained to a few chance matches.

View Article and Find Full Text PDF

The Advanced Light Source beamline-9.3.1 x-rays are used to calibrate the rocking curve of bent potassium acid phthalate (KAP) crystals in the 2.

View Article and Find Full Text PDF

Fuji TR image plate is frequently used as a replacement detector medium for x-ray imaging and spectroscopy diagnostics at NIF, Omega, and Z facilities. However, the familiar Fuji BAS line of image plate scanners is no longer supported by the industry, and so a replacement scanning system is needed. While the General Electric Typhoon line of scanners could replace the Fuji systems, the shift away from photo stimulated luminescence units to 16-bit grayscale Tag Image File Format (TIFF) leaves a discontinuity when comparing data collected from both systems.

View Article and Find Full Text PDF

At Sandia National Laboratories, the x-ray generator Manson source model 5 was upgraded from 10 to 25 kV. The purpose of the upgrade is to drive higher characteristics photon energies with higher throughput. In this work we present characterization studies for the source size and the x-ray intensity when varying the source voltage for a series of K-, L-, and M-shell lines emitted from Al, Y, and Au elements composing the anode.

View Article and Find Full Text PDF

Recently, frequency-resolved iron opacity measurements at electron temperatures of 170-200 eV and electron densities of (0.7-4.0)×10(22)cm(-3) revealed a 30-400% disagreement with the calculated opacities [J.

View Article and Find Full Text PDF

The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented.

View Article and Find Full Text PDF