Publications by authors named "Loic Marchin"

The microbial contamination of eye drop tips and caps varies between 7.7% and 100%. In seeking patient protection and continuous improvement, the Pharmacy Department in the Sterile Ophthalmological and Oncological Preparations Unit at Cochin Hospital AP-HP, Paris, France, conducted a two-phase study to compare the antimicrobial efficiency and practical use of standard packaging and a marketed eye drop container incorporating a self-decontaminating antimicrobial green technology by Pylote SAS at the tip and cap sites.

View Article and Find Full Text PDF

The antimicrobial activity of surfaces treated with zinc and/or magnesium mineral oxide microspheres is a patented technology that has been demonstrated in vitro against bacteria and viruses. This study aims to evaluate the efficiency and sustainability of the technology in vitro, under simulation-of-use conditions, and in situ. The tests were undertaken in vitro according to the ISO 22196:2011, ISO 20473:2013, and NF S90-700:2019 standards with adapted parameters.

View Article and Find Full Text PDF

The sterility of eye drop content is a primary concern from manufacturing until opening, as well as during handling by end users, while microbial contamination of the dropper tip and cap are often disregarded. The contamination of these sites during drug administration represents a risk of microbial transmission and ocular infection. In this review, we aim to assess microbial contamination of the dropper tip and cap of in-use eye drops, the associated contributory factors, and the risk of infection.

View Article and Find Full Text PDF