Dupilumab is an interleukin-4 receptor antagonist important in the treatment of refractory atopic dermatitis (AD), particularly among pediatric patients. Two boys with a history of AD and cardiac transplant who developed psoriasiform dermatitis in response to dupilumab therapy are reported. These patients paradoxically developed an immune-mediated adverse drug reaction despite taking systemic immunosuppressive agents.
View Article and Find Full Text PDFLarge laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal.
View Article and Find Full Text PDFA 20-month-old female with a past medical history of tuberous sclerosis, epilepsy, and infantile spasms treated with vigabatrin presented for surveillance MRI for multiple brain hamartomatous lesions and subependymal nodules. MRI showed new restricted diffusion to bilateral thalami and globi pallidi. This finding was concerning for bilateral thalamic strokes, with differential to include infection, metabolic etiologies, or toxic injuries.
View Article and Find Full Text PDFHand-foot skin reaction (HFSR) is a documented cutaneous adverse reaction to tyrosine kinase inhibitor (TKI) chemotherapy. Cutaneous toxicities such as HFSR can be debilitating and may result in serious complications; however, continued chemotherapy is desirable to optimize the patient's odds of survival and tumor remission. We present a case of a 66-year-old male, with a history of metastatic renal clear cell carcinoma, who was diagnosed with grade 3 HFSR triggered by axitinib, a tyrosine kinase inhibitor.
View Article and Find Full Text PDFPlastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al.
View Article and Find Full Text PDFPurpose Of Review: Inpatient teledermatology is a rapidly growing field with significant potential to add value and streamline patient care. This review summarizes the current literature on inpatient teledermatology, primarily focusing on its diagnostic and clinical management utility as compared to live dermatologic evaluation.
Recent Findings: The COVID-19 pandemic has accelerated the adoption of inpatient teledermatology, which has been shown to be comparable to live hospitalist evaluation for triage, diagnosis, and management of hospitalized patients for a wide variety of conditions.
We report experimental and modeling results for the charge state distribution of laboratory photoionized neon plasmas in the first systematic study over nearly an order of magnitude range of ionization parameter ξ∝F/N_{e}. The range of ξ is achieved by flexibility in the experimental platform to adjust either the x-ray drive flux F at the sample or the electron number density N_{e} or both. Experimental measurements of photoionized plasma conditions over such a range of parameters enable a stringent test of atomic kinetics models used within codes that are applied to photoionized plasmas in the laboratory and astrophysics.
View Article and Find Full Text PDFDuring the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements.
View Article and Find Full Text PDFWe describe two orthogonal radiography geometries at the OMEGA EP laser facility, which we refer to as side-on and face-on radiography. This setup can be used to determine quantitative information about the areal densities in solid, particulate, or liquid samples. We show sample images from these two different platforms that use the radiography diagnostic, one of material microjetting by the Richtmeyer-Meshkov instability and one of a deforming tin sample by the Rayleigh-Taylor instability, demonstrating the versatile applicability of such measurements in the field of high-energy density physics.
View Article and Find Full Text PDFRadiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. We present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ∼100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (∼2 kJ, 10 ps).
View Article and Find Full Text PDFWe discuss the experimental and modeling results for the x-ray heating and temperature of laboratory photoionized plasmas. A method is used to extract the electron temperature based on the analysis of transmission spectroscopy data that is independent of atomic kinetics modeling. The results emphasized the critical role of x-ray heating and radiation cooling in determining the energy balance of the plasma.
View Article and Find Full Text PDFAtom-in-jellium calculations of the Einstein frequency were used to calculate the mean displacement of an ion over a wide range of compression and temperature. Expressed as a fraction of the Wigner-Seitz radius, the displacement is a measure of the asymptotic freedom of the ion at high temperature, and thus of the change in heat capacity from six to three quadratic degrees of freedom per atom. A functional form for free energy was proposed based on the Maxwell-Boltzmann distribution as a correction to the Debye free energy, with a single free parameter representing the effective density of potential modes to be saturated.
View Article and Find Full Text PDFRecent path-integral Monte Carlo and quantum molecular dynamics simulations have shown that computationally efficient average-atom models can predict thermodynamic states in warm dense matter to within a few percent. One such atom-in-jellium model has typically been used to predict the electron-thermal behavior only, although it was previously developed to predict the entire equation of state (EOS). We report completely atom-in-jellium EOS calculations for Be, Al, Si, Fe, and Mo, as elements representative of a range of atomic number and low-pressure electronic structure.
View Article and Find Full Text PDFThe Orion high-resolution X-ray (OHREX) imaging spherically bent crystal spectrometer, operated with both image plates and CCD cameras, provides time-averaged plasma diagnostics through high-resolution spectroscopy with good signal-to-noise at the Orion laser facility. In order to provide time-resolved spectra, the OHREX will be outfitted with a streak camera, and in this case, even higher signal to noise will be desired. Using the OHREX's sister instrument, the EBIT High-resolution X-ray (EBHiX) spectrometer, at the LLNL electron beam ion trap EBIT-I, we therefore compare the efficiency of a high-quality Ge (111) crystal (2 = 6.
View Article and Find Full Text PDFThe warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple.
View Article and Find Full Text PDFIn an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, , experienced by the ions, the electron beam size, the nominal electron density , and the ion distribution around the beam, i.
View Article and Find Full Text PDFRev Sci Instrum
October 2008
Experiments performed at the Sandia National Laboratories (SNL) Z-machine, located in Albuquerque, New Mexico produce hot (approximately 220 eV) plasmas. X-ray emission from the plasma is used to drive radiation flow experiments. Our standard plasma diagnostic suite consists of x-ray diodes (XRDs), silicon photodiodes, and nickel thin film bolometers.
View Article and Find Full Text PDFThe photoemissive cathode type of x-ray diode (XRD) is popular for measuring time and spectrally resolved output of pulsed power experiments. Vitreous carbon XRDs currently used on the Sandia National Laboratories Z-machine were designed in the early 1980s and use materials and processes no longer available. Additionally cathodes used in the high x-ray flux and dirty vacuum environment of a machine such as Z suffer from response changes requiring recalibration.
View Article and Find Full Text PDFJ Reprod Fertil
September 1992
Uterine samples were either rapidly frozen in liquid nitrogen or placed in Bouin's fixative. A commercial primary polyclonal antibody made in rabbits against human recombinant basic fibroblast growth factor (bFGF) was used. Western blot analysis indicated that the antibody was specific for bFGF and did not react with acidic FGF.
View Article and Find Full Text PDF