Publications by authors named "Lloyd H Back"

Invasive diagnosis of coronary artery disease utilizes either anatomical or functional measurements. In this study, we tested a futuristic parameter, lesion flow coefficient (LFC, defined as the ratio of percent coronary area stenosis (%AS) to the square root of the ratio of the pressure drop across the stenosis to the dynamic pressure in the throat region), that combines both the anatomical (%AS) and functional measurements (pressure and flow) for application in a clinical setting. In 51 vessels, simultaneous pressure and flow readings were obtained using a 0.

View Article and Find Full Text PDF

The assessment of functional coronary lesion severity using intracoronary hemodynamic parameters like the pressure-derived fractional flow reserve and the flow-derived coronary flow reserve are known to rely critically on the establishment of maximal hyperemia. We evaluated a hyperemia-free index, basal pressure drop coefficient (bCDP), that combines pressure and velocity for simultaneous assessment of the status of both epicardial and microvascular circulations. In 23 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual-sensor tipped guidewire in the settings of both normal and abnormal microcirculation with the presence of epicardial lesions of area stenosis (AS) < 50% and AS > 50%.

View Article and Find Full Text PDF

Objectives And Background: Functional assessment of coronary lesion severity during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR; pressure derived) and coronary flow reserve (CFR; flow derived). However, the complex hemodynamics of stenosis might not be sufficiently explained by either pressure or flow alone, particularly in the case of intermediate stenosis. CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a non-dimensional index derived from fundamental fluid dynamic principles based on a combination of intracoronary pressure and flow, may improve the functional assessment of coronary lesion severity.

View Article and Find Full Text PDF

The study of hemodynamics in an animal model simulating coronary stenosis has been limited due to the lack of a safe, accurate and reliable technique for creating an artificial stenosis. Creating artificial stenosis using occluders in an open-chest procedure has often caused myocardial infarction (MI) or severe injury to the vessel resulting in high failure rates. To minimize these issues, closed-chest procedures with internal balloon obstruction are often used to create an artificial stenosis.

View Article and Find Full Text PDF

In current practice, diagnostic parameters, such as fractional flow reserve (FFR) and coronary flow reserve (CFR), are used to determine the severity of a coronary artery stenosis. FFR is defined as the ratio of hyperemic pressures distal (p(rh)) and proximal (p(ah)) to a stenosis. CFR is the ratio of flow at hyperemic and basal condition.

View Article and Find Full Text PDF

Objectives And Background: Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV).

View Article and Find Full Text PDF

Background: Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high practical importance.

Methods: In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δp-Q, curves for three different percentage area blockages corresponding to moderate (64%), intermediate (80%), and severe (90%) stenoses.

View Article and Find Full Text PDF

Background: Simultaneously measured pressure and flow distal to coronary stenoses can be combined, in conjunction with anatomical measurements, to assess the status of both the epicardial and microvascular circulations.

Methods And Results: Assessments of coronary hemodynamics were performed using fundamental fluid dynamics principles. We hypothesized that the pressure-drop coefficient (CDPe; trans-stenotic pressure drop divided by the dynamic pressure in the distal vessel) correlates linearly with epicardial and microcirculatory resistances concurrently.

View Article and Find Full Text PDF

Functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the stenosis. However, when there are functional collaterals operating downstream to the stenosis, the coronary flow-rate increases, and the pressure in the stenosed artery is altered.

View Article and Find Full Text PDF

Background: The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis.

View Article and Find Full Text PDF

Background: Functional/physiological evaluation of coronary artery stenoses may be more important than anatomical measurements of severity. Optimization of thresholds for stenosis intervention and treatment endpoints depend on coupling functional hemodynamic and anatomical data. We sought to develop a single prognostic parameter correlating stenosis-specific anatomy, pressure gradient, and velocities that could be measured during catheterization.

View Article and Find Full Text PDF

The coupled oxygen transport in the avascular wall of a coronary artery stenosis is studied numerically by solving the convection-diffusion equations. Two geometries replicating stenosis before and after percutaneous transluminal coronary angioplasty (PTCA) are used for the analysis. The results are compared to evaluate the effect of the degree of stenosis on oxygen transport.

View Article and Find Full Text PDF

The patho-physiologic process of restenosis and tissue growth may not be completely eliminated and is the primary concern of clinicians performing angioplasty and stent implantation procedures. Recent evidence suggests that the restenosis process is influenced by several factors: (1) geometry and size of vessel; (2) stent design; and (3) it's location that alter hemodynamic parameters, including local wall shear stress (WSS) distributions. The present three-dimensional (3D) analysis of pulsatile flow in a deployed coronary stent: (1) shows complex 3D variation of hemodynamic parameters; and (2) quantifies the changes in local WSS distributions for developed flow and compares with recently published WSS data for developing flow.

View Article and Find Full Text PDF

A major consequence of stent implantation is restenosis that occurs due to neointimal formation. This patho-physiologic process of tissue growth may not be completely eliminated. Recent evidence suggests that there are several factors such as geometry and size of vessel, and stent design that alter hemodynamic parameters, including local wall shear stress distributions, all of which influence the restenosis process.

View Article and Find Full Text PDF

Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance microvascular disease. In this study, a more comprehensive diagnostic parameter, named as lesion flow coefficient, c, is proposed.

View Article and Find Full Text PDF

To evaluate the local hemodynamic effects of coronary artery balloon angioplasty, computational fluid dynamics was applied to representative stenoses geometry post-angioplasty (minimal lesion diameter d(m) = 1.8mm which produced 64% mean area stenoses) based on a group of patients and measured values of coronary flow reserve (CFR) returning to a normal range (3.6+/-0.

View Article and Find Full Text PDF

The coupled oxygen transport in the avascular wall of a coronary artery stenosis is studied by numerically solving the convection-diffusion equations. Geometry, replicating residual stenosis after percutaneous transluminal coronary angioplasty (PTCA), is used for the analysis. Important physiological aspects, such as oxygen consumption in the wall, oxygen carried by the hemoglobin, non-Newtonian viscosity of the blood, and supply of oxygen from the vasa vasorum are included.

View Article and Find Full Text PDF

Hemodynamic analysis was conducted to determine uncertainty in clinical measurements of coronary flow reserve (CFR) and fractional flow reserve (FFR) over pathophysiological conditions in a patient group with coronary artery disease during angioplasty. The vasodilation-distal perfusion pressure (CFR-p(rh)) curve was obtained for 0.35- and 0.

View Article and Find Full Text PDF

This study gains insight on the nature of flow blockage effects of small guidewire catheter sensors in measuring mean trans-stenotic pressure gradients Deltap across significant coronary artery stenoses. Detailed pulsatile hemodynamic computations were made in conjunction with previously reported clinical data in a group of patients with clinically significant coronary lesions before angioplasty. Results of this study ascertain changes in hemodynamic conditions due to the insertion of a guidewire catheter (di=0.

View Article and Find Full Text PDF

To evaluate the local hemodynamics in flow limiting coronary lesions, computational hemodynamics was applied to a group of patients previously reported by Wilson et al. (1988) with representative pre-angioplasty stenosis geometry (minimal lesion size d(m)=0.95 mm; 68% mean diameter stenosis) and with measured values of coronary flow reserve (CFR) in the abnormal range (2.

View Article and Find Full Text PDF