Publications by authors named "Lisa P Clark"

Purpose Of Review: This review examines algorithm design features that may reduce risk for hypoglycemia while preserving glycemic control during intravenous insulin infusion. We focus principally upon algorithms in which the assignment of the insulin infusion rate (IR) depends upon maintenance rate of insulin infusion (MR) or a multiplier.

Recent Findings: Design features that may mitigate risk for hypoglycemia include use of a mid-protocol bolus feature and establishment of a low BG threshold for temporary interruption of infusion.

View Article and Find Full Text PDF