Publications by authors named "Lisa Meintker"

Background: Rapid galactomannan tests, such as the sõna Aspergillus GM Lateral Flow Assay (GM-LFA) and the Aspergillus Galactomannan Ag VIRCLIA® Monotest (GM-Monotest), which are suitable for the analysis of single samples, have the potential to accelerate diagnosis of invasive aspergillosis (IA).

Objectives: To compare the performance of the GM-Monotest and the GM-LFA for the diagnosis of IA.

Patients/methods: Two patient cohorts were analysed: adults who had received an allogeneic haematopoietic stem-cell transplant (alloHSCT-cohort) and patients with proven/probable IA from a 5-year period (cross-sectional IA-cohort).

View Article and Find Full Text PDF

Multi-parameter flow cytometry (MFC) is a cornerstone in clinical decision making for leukemia and lymphoma. MFC data analysis requires manual gating of cell populations, which is time-consuming, subjective, and often limited to a two-dimensional space. In recent years, deep learning models have been successfully used to analyze data in high-dimensional space and are highly accurate.

View Article and Find Full Text PDF
Article Synopsis
  • Graft-versus-host disease (GvHD) is a significant issue in stem cell transplants, and the study distinguishes between DM-sensitive and DM-resistant antigens based on their interaction with HLA-DM and HLA-DO.
  • Mutants of antigens were created to analyze their effects on T-cell responses, leading to insights into the behavior of DM-sensitive versus DM-resistant epitopes and their role in T-cell activation.
  • The results revealed that DM-sensitive antigens can trigger stronger T-cell activation in specific conditions, suggesting a potential strategy for enhancing graft-versus-leukemia effects without exacerbating GvHD.
View Article and Find Full Text PDF

Background: The new Rasamsonia spp. complex can develop invasive infection in immunosuppression or chronic pulmonary disease. It has potential to be misidentified as other genera due to morphological similarities.

View Article and Find Full Text PDF

In patients with hematological malignancies, bronchoalveolar lavage fluid (BALF) specimens are commonly used for the diagnosis of mold infections. However, it is not clear whether the cell pellet (P) or the supernatant fraction (S) of the BALF specimen is optimal for molecular diagnostic testing. Thus, 99 BALF specimens were collected from 96 hematology patients with or without allogeneic hematopoietic stem cell transplant.

View Article and Find Full Text PDF

Detection of immature platelets in the circulation may help to dissect thrombocytopenia due to platelet destruction from bone marrow failure (BMF). We prospectively tested the predictive value of immature platelets, measured as immature platelet fraction (IPF) on the XE-5000 (Sysmex, Kobe, Japan) or percentage of reticulated platelets (rPT) on the CD Sapphire (Abbott Diagnostics, Santa Clara, CA, USA) to separate immune thrombocytopenia (ITP) from BMF (leukaemia, myelodysplastic syndrome, aplastic anaemia). We analysed 58 samples of patients with BMF, 47 samples of patients with ITP and 97 controls.

View Article and Find Full Text PDF

Background: Measurement of immature platelets was introduced into routine diagnostics by Sysmex as immature platelet fraction (IPF) some years ago and recently by Abbott as reticulated platelet fraction (rPT). Here, we compare both methods.

Methods: We evaluated the precision and agreement of these parameters between Sysmex XE-5000 and Abbott CD-Sapphire in three distinct thrombocytopaenic cohorts: 30 patients with beginning thrombocytopaenia and 64 patients with recovering platelets (PLT) after chemotherapy, 16 patients with immune thrombocytopaenia (ITP) or heparin-induced thrombocytopaenia type 2 (HIT) and 110 additional normal controls.

View Article and Find Full Text PDF

Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in a total of 202 samples from hematology patients and normal controls. Manual differential count was used as reference.

View Article and Find Full Text PDF