Objectives: To investigate the impact of simulated gastric acid on the surface properties of lithium disilicate-reinforced glass-ceramics and zirconia-reinforced lithium silicate glass-ceramic after certain polishing and glazing procedures.
Materials And Methods: Four different types of square-shaped specimens (10 × 10 × 2 mm, n = 13) were manufactured: lithium disilicate-reinforced glass-ceramic milled and polished (LDS-P); milled, polished, and glazed (LDS-PG); milled, glazed, and no polishing (LDS-G); and milled and polished zirconia-reinforced lithium silicate glass-ceramic (ZR-LS). Specimens were immersed in hydrochloride acid (HCl 0.
This laboratory study aimed to measure the push-out bond strength of individually formed fiber-reinforced composite (FRC) post luted with flowable short fiber-reinforced composite (SFRC) and to evaluate the influence of post coating with light-cured adhesive. Post spaces (Ø 1.7 mm) were drilled into 20 single-rooted decoronated premolar teeth.
View Article and Find Full Text PDFPurpose: The aim of this study is to evaluate the mechanical and adhesive properties of three different resin cements with bioactive glass (BAG) incorporated in two different ratios.
Methods: BAG was added to different resin cements (3M Rely-X Ultimate, GC Link Ace, and GC Link Force) in different ratios (5% and 10% by weight). The three-point flexural strength, microhardness, and bond strength properties were evaluated.
The purpose of this study was to evaluate the effects of interpenetrating polymer network (IPN) thermoplastic resin on the flexural strength of fibre-reinforced composite (FRC) with different IPN polymer compositions. The penetration of bonding resin into semi-IPN FRC posts was also evaluated. The IPN thermoplastic resin used was UDMA-MMA monomer with either PMMA (0.
View Article and Find Full Text PDFThe use of bioresorbable fracture fixation plates made of aliphatic polyesters have good potential due to good biocompatibility, reduced risk of stress-shielding, and eliminated need for plate removal. However, polyesters are ductile, and their handling properties are limited. We suggested an alternative, PLAMA (PolyLActide functionalized with diMethAcrylate), for the use as the matrix phase for the novel concept of the in situ curable bioresorbable load-bearing composite plate to reduce the limitations of conventional polyesters.
View Article and Find Full Text PDFStatement Of Problem: The fracture incidence of implant-supported overdentures is more frequent in the area of attachment because of stress concentration and denture deformation in this area. How E-glass fiber reinforcement can address this problem is unclear.
Purpose: The purpose of this in vitro study was to evaluate the influence of unidirectional E-glass fiber reinforcement on the mid-line denture base strains of single implant-supported overdentures.
Fiber reinforced composites (FRCs) are metal free materials that have many applications in dentistry. In clinical orthodontics, they are used as retainers after active treatment in order to avoid relapse. However, although the modulus of the elasticity of FRCs is low, the rigidity of the material in the form of a relatively thick retainer with a surface cover of a flowable resin composite is known to have higher structural rigidity than stainless steel splints.
View Article and Find Full Text PDFThe aim of this study was to assess the chewing fracture resistance of compromised molars restored with direct composite resin (CR) restorations, with and without a short-fiber reinforcing (short-FRC) base. Wide extension of MOD cavities with removed palatal cusps preparations were simulated on 48 extracted maxillary molars. Five groups (n = 12) were designed: 1.
View Article and Find Full Text PDFFiber-reinforced composite (FRC) retainers are an aesthetic alternative to conventional Stainless Steel splints. They are generally used with a full bonded technique, but some studies demonstrated that they could be managed with a spot bonding technique to significantly decrease their rigidity. In order to propose this FRC spot bonding technique for clinical use, the aim of this study was to evaluate mechanical properties and surface wear of fibers left uncovered.
View Article and Find Full Text PDFCellulose nanofiber (CNF) made from wood-derived fiber is considered as a potential alternative reinforcing material to conventional fibers. The aim of this study was to investigate the effect of CNF on the flexural properties of CNF-reinforced, injection molded, polymethyl methacrylate (PMMA) denture base material. Test specimens were fabricated from a model thermoplastic denture base resin using the injection molding technique.
View Article and Find Full Text PDFIn toy-breed dogs (bodyweight <5 kg), the fractures of the radius and ulna are particularly common and can be caused by minimal trauma. While fracture fixation using metallic plates is a feasible treatment modality, the excessive stiffness of these devices produces the underloading of the bone which may result in the adverse bone remodelling and complications in the healing of the fracture. In this study, we investigated bisphenol A glycidylmethacrylate -based glass fibre reinforced composites as potential alternatives to metals in the devices intended for the fracture fixation of the distal radius in toy-breed dogs.
View Article and Find Full Text PDFStatement Of Problem: The incidence of fracture in a single-implant overdenture base increases in the region adjacent to the fulcrum implant.
Purpose: The purpose of this in vitro study was to evaluate the effect of bidirectional woven electrical glass (E-glass) fiber reinforcements on the fatigue resistance of a simulated single LOCATOR-retained overdenture.
Material And Methods: Test specimens with a centrally positioned metal housing for a LOCATOR stud attachment were fabricated from autopolymerizing acrylic resin.
Background: The aim of the study was to assess bacterial sealability and bonding ability of methacrylate-based Resilon (RS, SybronEndo), Endo Rez (ER, Ultradent Products Inc), and epoxy-based AH Plus (AH, Dentsply/DeTrey), MTA Fill Apex (MTAF, Angelus Soluções Odontológicas) root canal sealers, and the effect of the smear layer removal on the sealability.
Methods: One hundred thirty root segments were instrumented up to apical size #60 and rinsed with 2.5% NaOCl.
The reinforcement of resins with short or long fibers has multiple applications in various engineering and biomedical fields. The use of fiber reinforced composites (FRCs) in dentistry has been described in the literature from more than 40 years. In vitro studies evaluated mechanical properties such as flexural strength, fatigue resistance, fracture strength, layer thickness, bacterial adhesion, bonding characteristics with long fibers, woven fibers, and FRC posts.
View Article and Find Full Text PDFThis study aimed to evaluate and compare the effect of 1% phytic acid as a mixing medium on the setting times and diametral tensile strengths of different calcium silicate-based cements. Specimens for four experimental groups (n = 20/each) were fabricated by mixing ProRoot MTA (Dentsply) and Biodentine (Septodont) powders with their original liquids or with 1% phytic acid. Half of the samples in each group were immediately subjected to setting time tests, whereas the remaining half was subjected to the diametral tensile strength test after 3 weeks.
View Article and Find Full Text PDFActa Biomater Odontol Scand
July 2018
Aim: This study investigated the reinforcing effect of discontinuous glass microfibers with various loading fractions on selected mechanical properties of self-cure glass ionomer cement (GIC).
Method: Experimental fiber reinforced GIC (Exp-GIC) was prepared by adding discontinuous glass microfiber (silane/non-silane treated) of 200-300 µm in length to the powder of self-cure GIC (GC Fuji IX) with various mass ratios (15, 20, 25, 35, and 45 mass%) using a high speed mixing device. Flexural strength, flexural modulus, work of fracture, compressive strength and diametral tensile strength were determined for each experimental and control materials.
Statement Of Problem: Acrylic resin overdenture bases usually fracture because of stress concentrations at the area of the abutments.
Purpose: The purpose of this study was to evaluate the reinforcing effect of bidirectional woven electrical glass (E-glass) fiber weaves with a different number of layers and different locations on the load-bearing capacity of simulated Locator-retained overdenture specimens.
Material And Methods: Test specimens with a centrally located metal housing for a Locator stud attachment were fabricated from autopolymerizing acrylic resin (polymethylmethacrylate based) and reinforced with bidirectional woven E-glass fiber layers.
Purpose: This in vitro study aimed to evaluate the shear bond strength (SBS) of particulate filler composite (PFC) to saliva- or water-contaminated fiber-reinforced composite (FRC).
Materials And Methods: One type of FRC substrate with semi-interpenetrating polymer matrix (semi-IPN) (everStick C&B) was used in this investigation. A microhybrid PFC (Filtek Z250) substrate served as control.
New monolithic zirconia materials can be used to fabricate full-contour fixed dental prostheses with the computer-aided design/computer-aided manufacturing (CAD/CAM) method. The aim of this study was to examine the fracture strength and precision of fit of screw-retained monolithic zirconia crowns made directly on implants or by cementing on prefabricated titanium (Ti) bases. Monolithic screw-retained implant crowns (n = 6) were produced by CAD/CAM method using partially (PSZ) and fully stabilized (FSZ) zirconia.
View Article and Find Full Text PDFPurpose: The purpose of this study was to derive and compare the inherent color (hue angle, chroma), translucency (TP), surface gloss (ΔE), and surface roughness (R) amongst selected shades and brands of three hybrid CAD/CAM blocks [GC Cerasmart (CS); Lava Ultimate (LU); Vita Enamic (VE)].
Materials And Methods: The specimens (N = 225) were prepared into square-shaped (12 × 12 mm) with different thicknesses and shades. The measurements of color, translucency, and surface gloss were performed by a reflection spectrophotometer.
The objective of this study was to investigate several physicochemical properties of an experimental discontinuous S2-glass fiber-reinforced resin composite. The experimental composite was prepared by mixing 10 wt% of discontinuous S2-glass fibers with 27.5 wt% of resin matrix and 62.
View Article and Find Full Text PDFTo evaluate the influence of different materials on the load-bearing-capacity of inlay-retained fixed-dental-prosthesis (FDP). Ten types of FDPs were evaluated (n=7/group): Group PEEK: CAD-CAM polyetheretherketone (PEEK-TechnoMed), Group RC, made of discontinuous-fiber-composite (EverX Posterior); Group FRC1, made of discontinuous-fiber-composite (EverX Posterior) with two-bundles of continuous-unidirectional fiber-reinforced-composite (FRC) (Everstick C&B); Group FRC2, made of discontinuous-fiber-composite (EverX Posterior) with two-bundles of continuous-unidirectional-FRC (Everstick C&B) covered by two-pieces of short-unidirectional-FRC (Everstick C&B) placed perpendicular to the main-framework; Group FB, CAD-CAM fiber-block (Fibra-Composite Bio-C); Group PMMA, CAD-CAM polymethyl methacrylate block (Temp basic); Group RP, resin-paste; Group FRP1, made of resin-paste (G-Fix) with two-bundles of continuous-unidirectional-FRC (Everstick C&B); Group FRP2, made of resin-paste (G-Fix) two-bundles of continuous-unidirectional-FRC covered by two-pieces of short unidirectional-FRC placed perpendicular to the main-framework and Group exp-FRC, experimental CAD-CAM FRC. The bridges were statically-loaded until fracture.
View Article and Find Full Text PDFPurpose: The purpose of this study was to determine the flexural strength and Weibull characteristics of different CAD/CAM materials after different in vitro aging conditions.
Methods: The specimens were randomly assigned to one of the six in vitro aging conditions: (1) water storage (37°C, 3 weeks), (2) boiling water (24h), (3) hydrochloric acid exposure (pH: 1.2, 24h), (4) autoclave treatment (134°C, 200kPa, 12h), (5) thermal cycling (5000 times, 5-55°C), (6) cyclic loading (100N, 50,000 cycles).
Acta Biomater Odontol Scand
December 2016
The applications of single-structure fiber-reinforced composite (FRC) in restorative dentistry have not been well reported. This study aimed to clarify the static mechanical properties of anterior crown restorations prepared using two types of single-structure FRC. An experimental crown restoration was designed for an upper anterior incisor.
View Article and Find Full Text PDF