Purpose: Transducer positioning for liver ablation by magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) is challenging due to the presence of air-filled organs or bones on the beam path. This paper presents a software tool developed to optimize the positioning of a HIFU transducer dedicated to abdominal thermal therapy, to maximize the treatment's efficiency while minimizing the near-field risk.
Methods: A software tool was developed to determine the theoretical optimal position (TOP) of the transducer based on the minimization of a cost function using the particle swarm optimization (PSO).
Background: HIFU ablation of liver malignancies is particularly challenging due to respiratory motion, high tissue perfusion and the presence of the rib cage. Based on our previous development of a super-convergent phased-array transducer, we aimed to further investigate, in vivo, its applicability to deep intrahepatic targets.
Methods: In a series of six pigs, a pseudo-tumor model was used as target, visible both on intra-operatory MRI and post-mortem gross pathology.
MRI T1-mapping is an important non-invasive tool for renal diagnosis. Previous work shows that ΔT1 (cortex-medullary difference in T1) has significant correlation with interstitial fibrosis in chronic kidney disease (CKD) allograft patients. However, measuring cortico-medullary values by manually drawing ROIs over cortex and medulla (a gold standard method) is challenging, time-consuming, subjective and requires human training.
View Article and Find Full Text PDFMulti-slice, multiple breath-hold ECG-gated 2D cine MRI is a standard technique for evaluating heart function and restricted to one or two images per breath-hold. Therefore, the standard cine MRI requires long scan time and can result in slice-misalignments because of various breath-hold locations in the multiple acquisitions.This work proposes the sc-GROG based k-t ESPIRiT with Total Variation (TV) constraint (sc-GROG k-t ESPIRiT) to reconstruct unaliased cardiac real-time cine MR images from highly accelerated whole heart multi-slice, single breath-hold, real-time 2D cine radial data acquired using the balanced steady-state free precession (trueFISP) sequence in 8 patients.
View Article and Find Full Text PDFChronic thromboembolic pulmonary hypertension (CTEPH) is one of the causes of pulmonary hypertension (PH) and requires invasive measurement of the mean pulmonary artery pressure (mPAP) during right heart catheterisation (RHC) for the diagnosis. 4D flow MRI could provide non-invasive parameters to estimate the mPAP. Twenty-five patients with suspected CTEPH underwent cardiac MRI.
View Article and Find Full Text PDFPurpose: High-intensity focused ultrasound (HIFU) is challenging in the liver due to the respiratory motion and risks of near-/far-field burns, particularly on the ribs. We implemented a novel design of a HIFU phased-array transducer, dedicated to transcostal hepatic thermo-ablation. Due to its large acoustic window and strong focusing, the transducer should perform safely for this application.
View Article and Find Full Text PDFMagnetic resonance imaging (MRI) can be used to measure cardiac output (CO) non-invasively, which is a paramount parameter in pulmonary hypertension (PH) patients. We retrospectively compared stroke volume (SV) obtained with MRI (SV) in six localisations against SV measured with thermodilution (TD) (SV) and against each other in 24 patients evaluated in our PH centre using Bland and Altman (BA) agreement analyses, linear correlation, and intraclass correlation (ICC). None of the six tested localisations for SV reached the predetermined criteria for interchangeability with SV, with two standard deviations (2SD) of bias between 24.
View Article and Find Full Text PDFKidney cortical interstitial fibrosis is highly predictive of kidney prognosis and is currently assessed by evaluation of a biopsy. Diffusion-weighted magnetic resonance imaging is a promising non-invasive tool to evaluate kidney fibrosis. We recently adapted diffusion-weighted imaging sequence for discrimination between the kidney cortex and medulla and found that the cortico-medullary difference in apparent diffusion coefficient (ΔADC) correlated with histological interstitial fibrosis.
View Article and Find Full Text PDFMolecular medical imaging is intended to increase the accuracy of diagnosis, particularly in cardiovascular and cancer-related diseases, where early detection could significantly increase the treatment success rate. In this study, we present mixed micelles formed from four building blocks as a magnetic resonance imaging targeted contrast agent for the detection of atheroma and cancer cells. The building blocks are a gadolinium-loaded DOTA ring responsible for contrast enhancement, a fibrin-specific CREKA pentapeptide responsible for targeting, a fluorescent dye and DSPE-PEG.
View Article and Find Full Text PDFBackground: High intensity focused ultrasound (HIFU) is clinically accepted for the treatment of solid tumors but remains challenging in highly perfused tissue due to the heat sink effect. Endovascular liquid-core sonosensitizers have been previously suggested to enhance the thermal energy deposition at the focal area and to lower the near-/far-field heating. We are investigating the therapeutic potential of PFOB-FTAC micro-droplets in a perfused tissue-mimicking model and postmortem excised organs.
View Article and Find Full Text PDFThe compliance of the proximal aortic wall is a major determinant of cardiac afterload. Aortic compliance is often estimated based on cross-sectional area changes over the pulse pressure, under the assumption of a negligible longitudinal stretch during the pulse. However, the proximal aorta is subjected to significant axial stretch during cardiac contraction.
View Article and Find Full Text PDFPurpose: One of the challenges of cardiac MR imaging is the compensation of respiratory motion, which causes the heart and the surrounding tissues to move. Commonly-used methods to overcome this effect, breath-holding and MR navigation, present shortcomings in terms of available acquisition time or need to periodically interrupt the acquisition, respectively. In this work, an implementation of respiratory motion compensation that obtains information from abdominal ultrasound and continuously adapts the imaged slice position in real time is presented.
View Article and Find Full Text PDFIschemia/reperfusion (I/R) injury in acute myocardial infarction activates several deleterious molecular mechanisms. The transcription factor JunD regulates pathways involved in oxidative stress as well as in cellular proliferation, differentiation, and death. The present study investigated the potential role of JunD as a modulator of myocardial injury pathways in a mouse model of cardiac I/R injury.
View Article and Find Full Text PDFBackground: Magnetic resonance guided focused ultrasound was suggested for the induction of deep localized hyperthermia adjuvant to radiation- or chemotherapy. In this study we are aiming to validate an experimental model for the induction of uniform temperature elevation in osteolytic bone tumours, using the natural acoustic window provided by the cortical breakthrough.
Materials And Methods: Experiments were conducted on ex vivo lamb shank by mimicking osteolytic bone tumours.
The purpose of this study was to develop micron-sized droplet emulsions able to increase the heat deposition of high intensity focused ultrasound (HIFU), aiming to accelerate the tumour ablation in highly perfused organs with reduced side effects. The investigated droplets consisted of a perfluorooctyl bromide (PFOB) core coated with a biocompatible fluorinated surfactant called F-TAC. The novelty of this work relies on the use, for this application, of a high boiling point perfluorocarbon core (142 °C), combined with an in-house fluorinated surfactant to formulate the emulsion, yielding quasi-reversible strong interactions between the HIFU beam and the droplets.
View Article and Find Full Text PDFBackground: Kidney cortical interstitial fibrosis (IF) is highly predictive of renal prognosis and is currently assessed by the evaluation of a biopsy. Diffusion magnetic resonance imaging (MRI) is a promising tool to evaluate kidney fibrosis via the apparent diffusion coefficient (ADC), but suffers from inter-individual variability. We recently applied a novel MRI protocol to allow calculation of the corticomedullary ADC difference (ΔADC).
View Article and Find Full Text PDFA synthetic nano building block endowed with amphiphilic properties and chelated gadolinium is presented. Spontaneous self-assembly into small 12 nm corona-core stealth Gd-micelles with inherently high gadolinium loading occurs in water. Gd-Micelles are a new blood pool contrast agent with high relaxivity for magnetic resonance imaging.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
August 2019
Objective: High intensity focused ultrasound (HIFU) treatment in the abdominal cavity is challenging due to the respiratory motion. In the self-scanning HIFU ablation method, the focal spot is kept static and the heating pattern is obtained through natural tissue motion. This paper describes a novel approach for modulating the HIFU power during self-scanning in order to compensate for the effect of tissue motion on thermal buildup.
View Article and Find Full Text PDFObjective: Perfluorocarbon nano- and micron-sized emulsions are a new field of investigation in cancer treatment due to their ability to be used as imaging contrast agents, or as delivery vectors for pharmaceuticals. They also demonstrated capability to enhance the efficiency of high intensity focused ultrasound thermo-therapy. In the context of new biomedical applications we investigated perfluorooctyl bromide (PFOB) theranostic droplets using F NMR.
View Article and Find Full Text PDFObjective: We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging.
Methods: A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free.
Purpose: Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI.
Methods: A truly hybrid US-MR-guided HIFU method was used to plan and control the treatment.
Objectives: We validate a 4D strategy tailored for 3T clinical systems to simultaneously quantify function and infarct size in wild type mice after ischemia/reperfusion, with improved spatial and temporal resolution by comparison to previous published protocols using clinical field MRI systems.
Methods: C57BL/6J mice underwent 60min ischemia/reperfusion (n=14) or were controls without surgery (n=6). Twenty-four hours after surgery mice were imaged with gadolinium injection and sacrificed for post-mortem MRI and histology with serum also taken for Troponin I levels.
Purpose: To compare readout-segmented echo-planar imaging (EPI) (RESOLVE) to single-shot EPI (ss-EPI) diffusion-weighted imaging (DWI) for the assessment of renal interstitial fibrosis.
Materials And Methods: A phantom, eight healthy volunteers (under 30 years to avoid age-fibrosis related) and 27 chronic kidney disease (CKD) patients (scheduled for kidney biopsy) were scanned (at 3T) with ss-EPI and 5-shot RESOLVE DWI (resolution: 2 × 2 × 5 mm , 10 b-values). The cortico-medullary difference for each DW parameter from a monoexponential fit (ΔADC) or, segmented biexponential fit (ΔD, ΔD*, ΔF ) were compared between both sequences.
Purpose: In vivo liver cancer research commonly uses rodent models. One of the limitations of such models is the lack of accurate and reproducible endpoints for a dynamic assessment of growing tumor nodules. The aim of this study was to validate a noninvasive, true volume segmentation method using two rat hepatocellular carcinoma (HCC) models, correlating magnetic resonance imaging (MRI) with histological volume measurement, and with blood levels of α-fetoprotein.
View Article and Find Full Text PDF