Objectives: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods.
View Article and Find Full Text PDFObjectives: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments.
View Article and Find Full Text PDFObjectives: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations.
Methods: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column.
Objectives: An isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) was developed and validated to accurately measure serum and plasma concentrations of carbamazepine.
Methods: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was used to determine the absolute content of the reference material, ensuring its traceability to SI units. The separation of carbamazepine from potential interferences, whether known or unknown, was achieved using a C18 column.
Objectives: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy.
View Article and Find Full Text PDFObjectives: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma.
Methods: Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation.
Objectives: We developed an isotope dilution (ID)-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for lamotrigine in human serum and plasma, using quantitative nuclear magnetic resonance-characterized reference standards to ensure traceability to the International System of Units.
Methods: A sample preparation protocol based on protein precipitation combined with LC-MS/MS analysis using a C18 column for chromatographic separation was established for the quantification of lamotrigine in human serum and plasma. Assay validation was performed according to current guidelines.
Objectives: To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations.
Methods: A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement.
is a mycoparasitic fungus used as biological control agent against fungal plant pathogens. The recognition and appropriate morphogenetic responses to prey-derived signals are essential for successful mycoparasitism. We established microcolony confrontation assays using strains expressing cell division cycle 42 (Cdc42) and Ras-related C3 botulinum toxin substrate 1 (Rac1) interactive binding (CRIB) reporters to analyse morphogenetic changes and the dynamic displacement of localized GTPase activity during polarized tip growth.
View Article and Find Full Text PDFWhen mycophenolic acid (MPA) was originally marketed for immunosuppressive therapy, fixed doses were recommended by the manufacturer. Awareness of the potential for a more personalized dosing has led to development of methods to estimate MPA area under the curve based on the measurement of drug concentrations in only a few samples. This approach is feasible in the clinical routine and has proven successful in terms of correlation with outcome.
View Article and Find Full Text PDFTandem mass spectrometry - especially in combination with liquid chromatography (LC-MS/MS) - is applied in a multitude of important diagnostic niches of laboratory medicine. It is unquestioned in its routine use and is often unreplaceable by alternative technologies. This overview illustrates the development in the past decade (2009-2019) and intends to provide insight into the current standing and future directions of the field.
View Article and Find Full Text PDF