J Opt Soc Am A Opt Image Sci Vis
June 2023
Hartmann-Shack wavefront sensors (HSWSs) are used in many disciplines to measure optical aberrations. Conventionally, the wavefront of interest is transferred onto the lenslet array of the HSWS with a telescopic 4f relay system. However, the 4f relay design restricts the choice of focal lengths and distances used for the relay system.
View Article and Find Full Text PDFThis feature issue collects articles presented at the tenth Visual and Physiological Optics meeting (VPO2022), held August 29-31, 2022, in Cambridge, UK. This joint feature issue between Biomedical Optics Express and Journal of the Optical Society of America A includes articles that cover the broad range of topics addressed at the meeting and examples of the current state of research in the field.
View Article and Find Full Text PDFThis feature issue collects articles presented at the tenth Visual and Physiological Optics meeting (VPO2022), held August 29-31, 2022, in Cambridge, UK. This joint feature issue between and includes articles that cover the broad range of topics addressed at the meeting and examples of the current state of research in the field.
View Article and Find Full Text PDFThis study compares the effects on peripheral vision and image quality of four myopia control interventions: a) Perifocal spectacles/ArtOptica, b) Stellest spectacles/Essilor), c) MiyoSmart spectacles/Hoya and d) MiSight contact lenses/CooperVision. Five subjects participated with habitual or no correction as reference. Three techniques were used: 1) Hartmann-Shack sensors for wavefront errors, 2) double-pass imaging system for point-spread-functions (PSF), and 3) peripheral acuity evaluation.
View Article and Find Full Text PDFA novel double-pass instrument and its data analysis method for the measurement of central and peripheral refraction is presented and validated in a group of healthy subjects. The instrument acquires in-vivo, non-cycloplegic, double-pass, through-focus images of the eye's central and peripheral point-spread function (PSF) using an infrared laser source, a tunable lens and a CMOS camera. The through-focus images were analyzed to determine defocus and astigmatism at 0° and 30° visual field.
View Article and Find Full Text PDFIn their pioneering work demonstrating measurement and full correction of the eye's optical aberrations, Liang, Williams and Miller, [JOSA A14, 2884 (1997)10.1364/JOSAA.14.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
June 2022
Multifocal contact lenses are increasingly popular interventions for controlling myopia. This study presents the short-term effects of multifocal contact lenses on foveal and peripheral vision. The MiSight contact lenses designed to inhibit myopia progression and the 1-Day Acuvue Moist contact lenses designed for presbyopia were investigated.
View Article and Find Full Text PDFThe difference in peripheral retinal image quality between myopic and emmetropic eyes plays a major role in the design of the optical myopia interventions. Knowing this difference under accommodation can help to understand the limitations of the currently available optical solutions for myopia control. A newly developed dual-angle open-field sensor was used to assess the simultaneous foveal and peripheral ( nasal visual field) wavefront aberrations for five target vergences from -0.
View Article and Find Full Text PDFThe impact of peripheral optical errors induced by intraocular lenses was evaluated by simulating the average phakic and pseudophakic image qualities. An adaptive optics system was used to simulate the optical errors in 20° nasal and inferior visual field in phakic subjects. Peripheral resolution acuity, contrast sensitivity and hazard detection were evaluated.
View Article and Find Full Text PDFWe have developed a novel dual-angle open field wavefront sensor. This device captures real-time foveal and peripheral Zernike aberrations, while providing natural binocular viewing conditions for the subjects. The simultaneous data recording enables accurate analysis of changes in ocular optics with accommodation overcoming any uncertainties caused by accommodative lag or lead.
View Article and Find Full Text PDFPurpose: Many myopia control interventions are designed to induce myopic relative peripheral refraction. However, myopes tend to show asymmetries in their sensitivity to defocus, seeing better with hypermetropic rather than myopic defocus. This study aims to determine the influence of chromatic aberrations (CA) and higher-order monochromatic aberrations (HOA) in the peripheral asymmetry to defocus.
View Article and Find Full Text PDFPeripheral image quality influences several aspects of human vision. Apart from off-axis visual functions, the manipulation of peripheral optical errors is widely used in myopia control interventions. This, together with recent technological advancements enabling the measurement of peripheral errors, has inspired many studies concerning off-axis optical aberrations.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
April 2019
Correction and manipulation of peripheral refractive errors are indispensable for people with central vision loss and in optical interventions for myopia control. This study investigates further enhancements of peripheral vision by compensating for monochromatic higher-order aberrations (with an adaptive optics system) and chromatic aberrations (with a narrowband green filter, 550 nm) in the 20° nasal visual field. Both high-contrast detection cutoff and contrast sensitivity improved with optical correction.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
February 2019
The evidence-basis based on existing myopia control trials along with the supporting academic literature were reviewed; this informed recommendations on the outcomes suggested from clinical trials aimed at slowing myopia progression to show the effectiveness of treatments and the impact on patients. These outcomes were classified as primary (refractive error and/or axial length), secondary (patient reported outcomes and treatment compliance), and exploratory (peripheral refraction, accommodative changes, ocular alignment, pupil size, outdoor activity/lighting levels, anterior and posterior segment imaging, and tissue biomechanics). The currently available instrumentation, which the literature has shown to best achieve the primary and secondary outcomes, was reviewed and critiqued.
View Article and Find Full Text PDFSignificance: In the field of visual rehabilitation of patients with central visual field loss (CFL), knowledge on how peripheral visual function can be improved is essential. This study presents measurements of peripheral dynamic contrast sensitivity (with optical correction) for off-axis viewing angles in subjects with CFL.
Purpose: Subjects with CFL rely on a peripheral preferred retinal locus (PRL) for many visual tasks.
The blur experienced by our visual system is not uniform across the visual field. Additionally, lens designs with variable power profile such as contact lenses used in presbyopia correction and to control myopia progression create variable blur from the fovea to the periphery. The perceptual changes associated with varying blur profile across the visual field are unclear.
View Article and Find Full Text PDFOptimal temporal modulation of the stimulus can improve foveal contrast sensitivity. This study evaluates the characteristics of the peripheral spatiotemporal contrast sensitivity function in normal-sighted subjects. The purpose is to identify a temporal modulation that can potentially improve the remaining peripheral visual function in subjects with central visual field loss.
View Article and Find Full Text PDFAdaptive optics is a relatively new field, yet it is spreading rapidly and allows new questions to be asked about how the visual system is organized. The editors of this feature issue have posed a series of question to scientists involved in using adaptive optics in vision science. The questions are focused on three main areas.
View Article and Find Full Text PDFThe purpose of this study was to measure the transverse chromatic aberration (TCA) across the visual field of the human eye objectively. TCA was measured at horizontal and vertical field angles out to ±15° from foveal fixation in the right eye of four subjects. Interleaved retinal images were taken at wavelengths 543 nm and 842 nm in an adaptive optics scanning laser ophthalmoscope (AOSLO).
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
October 2016
Purpose: To quantify the effect of induced stray light on halo size, luminance threshold, and contrast sensitivity.
Methods: Retinal stray light was induced in five healthy subjects using different photographic filters. The stray light induced ranged from levels observed in intraocular lenses (IOLs) with glistenings (low) to cataract level (high).
Purpose: Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
October 2015
Transverse chromatic aberration (TCA) is one of the largest optical errors affecting the peripheral image quality in the human eye. However, the effect of chromatic aberrations on our peripheral vision is largely unknown. This study investigates the effect of prism-induced horizontal TCA on vision, in the central as well as in the 20° nasal visual field, for four subjects.
View Article and Find Full Text PDFA prolonged exposure to foveal defocus is well known to affect the visual functions in the fovea. However, the effects of peripheral blur adaptation on foveal vision, or vice versa, are still unclear. In this study, we therefore examined the changes in contrast sensitivity function from baseline, following blur adaptation to small as well as laterally extended stimuli in four subjects.
View Article and Find Full Text PDFMeasuring the contrast sensitivity function (CSF) in the periphery of the eye is complicated. The lengthy measurement time precludes all but the most determined subjects. The aim of this study was to implement and evaluate a faster routine based on the quick CSF method (qCSF) but adapted to work in the periphery.
View Article and Find Full Text PDFPurpose: The purpose of this study was twofold: to verify a fast, clinically applicable method for determining off-axis refraction and to assess the impact of objectively obtained off-axis refractive correction on peripheral low-contrast visual acuity.
Methods: We measured peripheral low-contrast resolution acuity with Gabor patches both with and without off-axis correction at 20 degrees in the nasal visual field of 10 emmetropic subjects; the correction was obtained using a commercial open-field Hartmann-Shack wavefront sensor, the COAS-HD VR aberrometer. Off-axis refractive errors were calculated for a 5-mm circular pupil inscribed within the elliptical wavefront by COAS using the instruments' inbuilt "Seidel sphere" method.