Publications by authors named "Linda Ahnen"

Necrotizing enterocolitis (NEC) is the most common gastrointestinal emergency of the preterm infant. Low abdominal tissue oxygen saturation (StO) measured by near-infrared spectroscopy (NIRS) oximetry may be an early sign of NEC relevant for treating or even preventing NEC. However, current commercial NIRS oximeters provide inaccurate StO readings because they neglect stool as an abdominal absorber.

View Article and Find Full Text PDF

Clinicians need a way to rapidly and reliably test the correct functioning of near-infrared spectroscopy (NIRS)-based oximeters. Therefore, optical phantoms for quality assessment of NIRS oximeters are needed. The fabrication of such phantoms that mimic the optical properties of biological tissue in the NIR range represents a challenge.

View Article and Find Full Text PDF

A minimal setup for optoacoustic (OA) imaging requires an ultrasound probe and a pulsed laser. Such a system is capable of imaging small blood vessels and is sensitive to variations in their oxygen saturation. However, absolute oxygenation values cannot be obtained without a proper correction for the varying light fluence resulting from the optical attenuation in the surrounding tissue.

View Article and Find Full Text PDF
Article Synopsis
  • Near-infrared optical tomography (NIROT) shows potential for studying brain function, but reconstructions can be affected by small surface features like birthmarks and hair.
  • Researchers tested whether artificial neural networks (ANN) could effectively address these surface perturbations in detecting brain activity.
  • The study found that ANNs can handle more significant skin variations than traditional Monte Carlo models, making them more effective for this purpose.
View Article and Find Full Text PDF

In vivo imaging of tissue/vasculature oxygen saturation levels is of prime interest in many clinical applications. To this end, the feasibility of combining two distinct and complementary imaging modalities is investigated: optoacoustics (OA) and near-infrared optical tomography (NIROT), both operating noninvasively in reflection mode. Experiments were conducted on two optically heterogeneous phantoms mimicking tissue before and after the occurrence of a perturbation.

View Article and Find Full Text PDF

The aim of this work was to measure optical properties of stool of mice to provide this relevant wavelength-dependent behavior for optical imaging modalities such as fluorescent molecular tomography and near-infrared optical tomography. BALB/c nude female mice were studied and optical properties of the stool were determined by employing the inverse adding-doubling approach. The animals were kept on chlorophyll-free diet.

View Article and Find Full Text PDF

The accuracy of images obtained by Diffuse Optical Tomography (DOT) could be substantially increased by the newly developed time resolved (TR) cameras. These devices result in unprecedented data volumes, which present a challenge to conventional image reconstruction techniques. In addition, many clinical applications require taking photons in air regions like the trachea into account, where the diffusion model fails.

View Article and Find Full Text PDF

Imaging brain oxygenation is crucial for preventing brain lesions in preterm infants. Our aim is to build and validate a near-infrared optical tomography (NIROT) sensor for the head of neonates. This sensor, combined with an optoacoustic device, will enable quantitative monitoring of the structural and functional information of the brain.

View Article and Find Full Text PDF

The Delta(4DVH) Anatomy 3D quality assurance (QA) system (ScandiDos), which converts the measured detector dose into the dose distribution in the patient geometry was evaluated. It allows a direct comparison of the calculated 3D dose with the measured back-projected dose. In total, 16 static and 16 volumetric-modulated arc therapy (VMAT) fields were planned using four different energies.

View Article and Find Full Text PDF