Gas chromatographic columns based on ionic liquids (ILs) are very promising since the selectivity of these columns can be tuned by both the cation and the anion chemical nature. In this paper, efficiencies of capillary columns based on four phosphonium ionic liquids were studied. The performance of seven columns containing the cation trihexyl(tetradecyl)phosphonium and the anions bromide, chloride, and bis(trifluoromethylsulfonyl)imide was evaluated by measuring the solute band broadening as a function of gas velocities at three temperatures.
View Article and Find Full Text PDFSuitable conditions of temperature and humidity are required to maintain wheat grains quality, but during processing and storage, the grains can be exposed to adverse environmental conditions and presence of infectious fungi. Fusarium graminearum, the main causal agent of Fusarium head blight on wheat, affects crop yields and grain quality by alteration of their biochemical components and mycotoxin contamination, which reduces the possibilities of wheat end use and compromises food safety. Lipid degradation by hydrolytic, oxidative and microbial deterioration is the predominant cause of the loss of sensory acceptability, nutritional value and baking quality.
View Article and Find Full Text PDFWe report here gas-liquid partition constants and activity coefficients for thirty-seven volatile organic solutes in ionic liquid trihexyl(tetradecyl)phosphonium dicyanamide measured by gas-liquid chromatography using capillary columns. Four capillary columns with exactly known phase ratios were constructed and employed to measure the solute retention factors at four temperatures between 313.15 and 343.
View Article and Find Full Text PDFIn this paper, we report gas-liquid partition constants for thirty-five volatile organic solutes in the room temperature ionic liquid trihexyl(tetradecyl)phosphonium bromide measured by gas-liquid chromatography using capillary columns. The relative contribution of gas-liquid partition and interfacial adsorption to retention was evaluated through the use of columns with different the phase ratio. Four capillary columns with exactly known phase ratios were constructed and employed to measure the solute retention factors at four temperatures between 313.
View Article and Find Full Text PDFThis study focused on an investigation into the experimental quantities inherent in the determination of partition coefficients from gas-liquid chromatographic measurements through the use of capillary columns. We prepared several squalane - (2,6,10,15,19,23-hexamethyltetracosane) - containing columns with very precisely known phase ratios and determined solute retention and hold-up times at 30, 40, 50 and 60°C. We calculated infinite dilution partition coefficients from the slopes of the linear regression of retention factors as a function of the reciprocal of the phase ratio by means of fundamental chromatographic equations.
View Article and Find Full Text PDFThe acidic dissociation enthalpies and constants of anilinium, protonated tris(hydroxymethyl)aminomethane (HTris(+)), benzoic and acetic acids, have been determined at several temperatures in pure water and in methanol/water mixtures by potentiometry and by isothermal titration microcalorimetry (ITC). The pK(a) values determined by both techniques are in accordance when the dissociation process involves large amounts of heat. However, for the neutral acids the ITC technique gave slightly lower pK(a) values than those from potentiometry at the highest temperatures studied due to the small amounts of heat involved in the acidic dissociation.
View Article and Find Full Text PDFEmploying a micro-bore silica capillary coated with Carbowax 20 M, the dependence of chromatographic retention upon operative variables was studied surpassing the sample capacity of the column. Solution thermodynamics in the non-linear range of the absorption isotherm of n-alkanes on poly(ethylene oxide) were analyzed interpreting the experimental data through a retention equation deduced in a preceding theoretical work. At 120 degrees C, and pressures up to 11 bar abs, deviations from the ideal-gas behavior are found to be negligible, either for the fluid dynamics of the carrier-gas, or the thermodynamics of solution of the n-alkanes.
View Article and Find Full Text PDFPeak-shape problems represent the most common troubles in liquid chromatography. Distorted peaks are causes for integration problems, and very often for poor resolutions. Sample and standard solvent different from that of the eluent is one of the possible reasons for anomalous peak-shapes.
View Article and Find Full Text PDF