Sensors (Basel)
September 2024
To address the issue of spatial resolution limitations in traditional Brillouin optical time-domain analysis systems due to phonon lifetime constraints, we employed pre-pumped pulse technology. Additionally, to mitigate the double-peak phenomenon observed in pre-pumped Brillouin optical time-domain analysis systems, we implemented a two-sided band interference method to reduce the linewidth of the double-peak fitting. We conducted bending measurements on three eccentric cores and intermediate cores spaced 120° apart.
View Article and Find Full Text PDFThe copy number of genes in chromosomes can be modified by chromosomal integration to construct efficient microbial cell factories but the resulting genetic systems are prone to failure or instability from triggering homologous recombination in repetitive DNA sequences. Finding the optimal copy number of each gene in a pathway is also time and labor intensive. To overcome these challenges, we applied a multiple nonrepetitive coding sequence calculator that generates sets of coding DNA sequence (CDS) variants.
View Article and Find Full Text PDFBased on the theory of the microwave photonic filter (MPF), to our knowledge, a novel fiber Bragg grating (FBG) wavelength demodulation method based on time-domain detection is proposed. The method uses VNA (vector network analyzer) to measure the S21 parameter of the sensor system, and converts them to the time-domain through inverse discrete Fourier transform (IDFT), The wavelength demodulation and positioning of FBG can be realized by measuring the amplitude and position of the time-domain peak. In order to improve the number of FBG multiplexes, a method is proposed to eliminate the effect of spectrum overlap by normalization in the case of two FBGs and three FBGs.
View Article and Find Full Text PDFAim: This study was designed to investigate the pharmacological effects and mechanisms of ErZhiTianGui Decoction (EZTG) for age-related ovarian aging in mice.
Methods: This study used naturally aging mice as a model, and EZTG was used for intragastric administration. Ovarian pathological changes, as well as follicular reserve were assessed by hematoxylin and eosin staining, and serum hormone levels (anti-mullerian hormone, follicle-stimulating hormone), mitochondrial reactive oxygen species (ROS) and mitochondrial DNA (mtDNA) damage marker 8-hydroxy-2'-deoxyguanosine(8-OHdG), and lipid peroxidation markers glutathione(GSH) and malondialdehyde(MDA) were determined by enzyme-linked immunosorbent assay.
Background: Age-related diminished ovarian reserve (DOR) is not absolute. Some advanced maternal age (AMA) still have normal ovarian reserve (NOR) and often show better pregnancy outcomes. Exploring the transcriptomic profile of granulosa cells (GCs) in AMA could lead to new ideas for mitigating age-related diminished ovarian reserve.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
February 2023
Objective: To evaluate different starting doses of recombinant human follicle-stimulating hormone (rhFSH) on pregnancy outcomes for patients with normal ovarian reserve during gonadotropin- releasing hormone antagonist (GnRH-ant) protocol-controlled ovarian stimulation of fertilization (IVF) cycles.
Methods: In this retrospective study, a total of 1138 patients undergoing IVF cycles following the GnRH-ant protocol were enrolled. Patients were divided into two groups according to the starting dose of rhFSH.
Background: Hypertensive intracerebral hemorrhage (HICH) seriously endangers the quality of life of patients and can even lead to death. Craniotomy is a common treatment method for HICH.
Objective: The aim of this study was to investigate the efficacy of two different sizes of craniotomy in patients with HICH, as well as to evaluate their effects on C-reactive protein (CRP) and blood lactate levels.
A stabilized narrow-linewidth random fiber laser for strain detection, based on a three-grating ring (TGR) resonator and half-open-cavity structure, is proposed and investigated experimentally. The half-open-cavity structure proved to provide double optical gain of erbium-doped fiber, which was beneficial to increase the photon lifetime as well as further narrow the linewidth. Meanwhile, the stability and frequency noise of narrow lasing output was improved by suppressing the competition-induced undesired residual random lasing modes with the TGR resonator.
View Article and Find Full Text PDFCreep behavior and fatigue life are important performance indexes that affect the long-term stability of resistive strain gauges. The resistive strain gauges, fabricated with wet etching and resistance trimming, present micro-morphology such as textures and uneven edges on the surface and side-wall profile of sensitive grids. This paper observed the micro-morphology of the sensitive grids by microscope and analyzed its range of geometric dimensions.
View Article and Find Full Text PDFMicromachines (Basel)
February 2022
The effect of micro-morphology of resistive strain gauges on gauge factor was investigated numerically and experimentally. Based on the observed dimensional parameters of various commercial resistive strain gauges, a modeling method had been proposed to reconstruct the rough sidewall on the sensitive grids. Both the amplitude and period of sidewall profiles are normalized by the sensitive grid width.
View Article and Find Full Text PDFOptical fiber sensing technology plays an important role in the application of the sensing layer of the Internet of Things. The core of this technology is the demodulation of the fiber Bragg grating (FBG) sensing system. Since the FBG sensor utilizes the wavelength change to respond to the measured size, it is of great significance to improve the accuracy of the FBG wavelength demodulation.
View Article and Find Full Text PDFProlonged chronic wound healing not only places great stress on patients but also increase the health care burden. Fortunately, the emergence of tissue-engineered dressings has provided a potential solution for these patients. Recently, the relationship between the wound microenvironment and wound healing has been gradually clarified.
View Article and Find Full Text PDFWound infection is a challenging clinical problem that imposes substantial economic and psychological burdens on patients. However, the wound covered by a dressing is in an 'unknown' state. Recently, researchers have focused on understanding the condition of the wound without removing the dressing.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
June 2021
Conventional electromagnetic acoustic transducers (EMATs) are generally only used to generate and detect guided waves with a single wavelength, which increases their sensitivity at that particular wavelength but limits their application scenarios and the accuracy of defect assessment. This article proposes a design method for multiwavelength EMATs based on spatial-domain harmonic control. First, the EMAT model is analyzed, where it is then outlined that the eddy-current density distribution of the specimen is equivalent to the spatial low-pass filtering of the coil-current density distribution.
View Article and Find Full Text PDFBackground: The administration of second- or third-generation anti-CD19 chimeric antigen receptor (CAR) T cells has remarkably improved the survival of patients with relapsed or refractory B cell malignancies. However, there are limited clinical results from fourth-generation CAR-T cell therapy, and the factors affecting response rate and survival have not been fully determined.
Methods: Lymphoma patients with progression or relapse after intensive treatments, including hematopoietic stem cell transplantation, and life expectancy >2 months were enrolled in the study.
Resistance strain force sensors have been applied to monitor the strains in various parts and structures for industrial use. Here, we review the working principles, structural forms, and fabrication processes for resistance strain gauges. In particular, we focus on recent developments in resistance stress transfer for resistance strain force sensors and the creep effect due to sustained loads and/or temperature variations.
View Article and Find Full Text PDFpH is a critical parameter used to specify the acidity or alkalinity of an aqueous solution in chemistry, food processing, and medical care. In this study, a conductimetric-type micro pH sensor has been achieved using PANI membrane fabricated on a flexible substrate film aiming to monitor wound healing. The sensor is based on the incorporation of a polyaniline (PANI) membrane, interdigital electrode, and polyimide (PI) substrate.
View Article and Find Full Text PDFThe photothermal characteristics of nanoparticles are of particular interest to biophotonic and biomedical applications due to their ability to efficiently localize thermal energy down to the nanometer scale. However, few works had demonstrated an efficient dissipation of heat to their nanoscale surrounding in response to optical excitation. Here, we demonstrate an efficient platform for optical nanoheating based on silicon nanocuboids.
View Article and Find Full Text PDFThe strain transfer characteristics of resistance strain gauge are theoretically investigated. A resistance strain-type transducer is modeled to be a four-layer and two-glue (FLTG) structure model, which comprises successively the surface of an elastomer sensitive element, a ground adhesive glue, a film substrate layer, an upper adhesive glue, a sensitive grids layer, and a polymer cover. The FLTG model is studied in elastic⁻mechanical shear lag theory, and the strain transfer progress in a resistance strain-type transducer is described.
View Article and Find Full Text PDFBackground: Prognosis of spontaneous intracerebral hemorrhage (ICH) remains poor worldwide.
Aims Of The Study: To investigate the effect and optimal protocol for hyperbaric-oxygen therapy (HBOT), and reduce incidence of upper gastrointestinal bleeding (UGIB) in ICH.
Methods: This prospective, randomized, controlled trial included 565 patients with acute severe ICH.
Objective: This retrospective study investigated the incidence and risk factors of poor clinical outcomes after cervical surgery for cervical spinal cord injury in a large population of patients with global or segmental cervical kyphosis.
Methods: The clinical and radiological evaluation results of 269 patients with cervical kyphosis who underwent either anterior or posterior surgery between 2008 and 2013 were collected, preoperatively and at each follow-up after surgery.
Results: All patients were followed for an average of 2.
Metal corrosion is of worldwide concern because it is the cause of major economic losses, and because it creates significant safety issues. The mechanism of the corrosion process, as influenced by bacteria, has been studied extensively. However, the bacterial communities that create the biofilms that form on metals are complicated, and have not been well studied.
View Article and Find Full Text PDFBackground: The purpose of the research was to evaluate cervical sagittal parameters on magnetic resonance imaging (MRI) in patients with Modic changes and its impact on axial neck pain.
Methods: This study consisted of 266 consecutive asymptomatic or symptomatic patients with Modic changes, whose average age was 50.9±12.