Purpose: We investigate the effect of the GafChromic™ film EBT3 model absorbed dose energy response when used for dose measurements around low-energy photon sources. Monte Carlo based correction procedure in synergy with appropriate calibration curves was shown to provide more accurate absorbed dose (either relative or absolute). An assessment was made of possible dose errors that might be encountered if such energy dependent response is ignored.
View Article and Find Full Text PDFPurpose: The Papillon technique using 50-kVp soft X-rays to treat rectal adenocarcinomas was developed and clinically implemented in the 1960s. We describe differences between accurate dosimetry and clinical implementation of this technique that is extending from its very inception to date.
Methods And Materials: A renaissance of the Papillon technique occurred with two recently introduced 50-kVp systems: Papillon+ by Ariane and a custom-made rectal applicator (consisting of a surface applicator inserted into a proctoscope) by iCAD's Xoft Axxent Electronic Brachytherapy (eBT) System (iCad, Inc.
Guang Pu Xue Yu Guang Pu Fen Xi
April 2015
Visible and near infrared spectroscopy is a proven technology to be widely used in identification and exploration of hydrocarbon energy sources with high spectral resolution for detail diagnostic absorption characteristics of hydrocarbon groups. The most prominent regions for hydrocarbon absorption bands are 1,740-1,780, 2,300-2,340 and 2,340-2,360 nm by the reflectance of oil sands samples. These spectral ranges are dominated by various C-H overlapping overtones and combination bands.
View Article and Find Full Text PDFPurpose: The authors investigated the energy response of XR-QA2 GafChromic™ film over a broad energy range used in diagnostic radiology examinations. The authors also made an assessment of the most suitable functions for both reference and relative dose measurements.
Methods: Pieces of XR-QA2 film were irradiated to nine different values of air kerma in air, following reference calibration of a number of beam qualities ranging in HVLs from 0.
High expression of vascular endothelial growth factor (VEGF) in patients with breast cancer has been associated with a poor prognosis, indicating that VEGF could be linked to the efficacy of chemotherapy and radiotherapy. It has also been suggested that radiation resistance is partly due to tumour cell production of angiogenic cytokines, particularly VEGF receptor (VEGFR). This evidence indicates that inhibition of VEGFR might enhance the radiation response.
View Article and Find Full Text PDFPurpose: A radiochromic film based dosimetry system for high dose rate (HDR) Iridium-192 brachytherapy source was described. A comparison between calibration curves established in water and Solid Water™ was provided.
Methods: Pieces of EBT-2 model GAFCHROMIC™ film were irradiated in both water and Solid Water™ with HDR (192)Ir brachytherapy source in a dose range from 0 to 50 Gy.
Purpose: The authors present results of the measurements on the impact of radiochromic film immersion in water. The impact of film piece size, initial optical density, postimmersion waiting time prior to scanning, and the time film was kept in water has been investigated. The authors also investigated the pathways of water penetration into the film during the film immersion in water.
View Article and Find Full Text PDFPurpose: One of the major drawbacks of the current radiochromic film dosimetry protocols is the postirradiation waiting time. In this article, the authors study the postirradiation time evolution of the absorption spectrum of radiochromic EBT-2 GAFCHROMIC film model.
Methods: Postirradiation scanning times range from 3 min to 5 days and a dose range extends from 0 to 6 Gy.