Background: The expansion of online education for nursing students has created the challenge of finding innovative ways to teach clinical skills. An online intravenous pump emulator (IVPE) modelled on actual IV pumps used in clinical healthcare settings was developed to facilitate online education delivery.
Objectives: The objectives of the study were to implement the online IVPE and evaluate student learning outcomes and perceptions of device use.
The application of pulsed mode ultrasound (PMU) as a pre-treatment for alum coagulation was investigated at various alum dosages and pH levels. The effects of the treatments on turbidity and dissolved organic carbon (DOC) removal and residual Al were evaluated. Response surface methodology (RSM) was utilized to optimize the operating conditions of the applied treatments.
View Article and Find Full Text PDFIn this study, the structural alteration to DOC for a range of ultrasound treatments was investigated with chemical fractionation and UV-vis spectroscopic measurement. Ultrasound treatments were applied in continuous and pulsed modes at power levels of 48 and 84 W for effective treatment times of 5 and 15 min. Overall results show that the ultrasound treatments tended to degrade the hydrophobic aromatic fraction, while increasing the hydrophilic fraction to a lesser extent.
View Article and Find Full Text PDFThe application of pulsed ultrasound for DOC removal from natural water samples has been thoroughly investigated in this work. Natural water samples were treated with ultrasound at power levels of 48 and 84 W with treatment times of 5 and 15 min. Chemical fractionation was conducted for both untreated and treated samples to clearly identify the change in DOC structure caused by ultrasonic treatments.
View Article and Find Full Text PDFTo date, the successful application of large scale ultrasound in water treatment has been a challenge. Magnetostrictive ultrasound technologies for constructing a large-scale water treatment system are proposed in this study. Comprehensive energy evaluation of the proposed system was conducted.
View Article and Find Full Text PDFObtaining accurate power characteristics of ultrasonic treatment systems is an important step towards their industrial scalability. Calorimetric measurements are most commonly used for quantifying the dissipated ultrasonic power. However, accuracy of these measurements is affected by various heat losses, especially when working at high power densities.
View Article and Find Full Text PDF