The pilot dose survey on paediatric general radiography, fluoroscopy and CT procedures was performed in four university hospitals. The analysis of data was focused on the radiography and CT imaging of head, chest, abdomen, pelvis and spine and fluoroscopic procedures of gastrointestinal and urinary tracts. The survey was conducted by the National Radiation Protection Institute.
View Article and Find Full Text PDFA comparison of calibration results and procedures in terms of air kerma length product, PKL, and air kerma, K, was conducted between eight dosimetry laboratories. A pencil-type ionization chamber (IC), generally used for computed tomography dose measurements, was calibrated according to three calibration methods, while its residual signal and other characteristics (sensitivity profile, active length) were assessed. The results showed that the "partial irradiation method" is the preferred method for the pencil-type IC calibration in terms of PKL and it could be applied by the calibration laboratories successfully.
View Article and Find Full Text PDFObjective: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries.
Methods: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses.
Results: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %.
Objective: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use.
Materials And Methods: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals.
Results: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.
Radiat Prot Dosimetry
December 2006
Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), and a quality of the whole process of diagnostic imaging (entrance surface air-kerma measurement, a check of film processing and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit.
View Article and Find Full Text PDF