Pressure-detecting insoles such as the Insole3 have potential as a portable alternative for assessing vertical ground reaction force (vGRF) outside of specialized laboratories. This study evaluated whether the Insole3 is a valid and reliable alternative to force plates for measuring vGRF. Eleven healthy participants walked overground at slow and moderately paced speeds and ran at a moderate pace while collecting vGRF simultaneously from a force plate (3000 Hz) and Insole3 (100 Hz).