Publications by authors named "Leonid S Barbarash"

The lack of suitable autologous grafts and the impossibility of using synthetic prostheses for small artery reconstruction make it necessary to develop alternative efficient vascular grafts. In this study, we fabricated an electrospun biodegradable poly(ε-caprolactone) (PCL) prosthesis and poly(3-hydroxybutyrate-co-3-hydroxyvalerate)/poly(ε-caprolactone) (PHBV/PCL) prosthesis loaded with iloprost (a prostacyclin analog) as an antithrombotic drug and cationic amphiphile with antibacterial activity. The prostheses were characterized in terms of their drug release, mechanical properties, and hemocompatibility.

View Article and Find Full Text PDF

Background Whereas the risk factors for structural valve degeneration (SVD) of glutaraldehyde-treated bioprosthetic heart valves (BHVs) are well studied, those responsible for the failure of BHVs fixed with alternative next-generation chemicals remain largely unknown. This study aimed to investigate the reasons behind the development of SVD in ethylene glycol diglycidyl ether-treated BHVs. Methods and Results Ten ethylene glycol diglycidyl ether-treated BHVs excised because of SVD, and 5 calcified aortic valves (AVs) replaced with BHVs because of calcific AV disease were collected and their proteomic profile was deciphered.

View Article and Find Full Text PDF

Fibrin is widely used in vascular tissue engineering. Typically, fibrin polymerization is initiated by adding exogenous thrombin. In this study, we proposed a protocol for the preparation of completely autologous fibrin without the use of endogenous thrombin and compared the properties of the prepared fibrin matrix with that obtained by the traditional method.

View Article and Find Full Text PDF

Tissue-engineered vascular graft for the reconstruction of small arteries is still an unmet clinical need, despite the fact that a number of promising prototypes have entered preclinical development. Here we test Poly(3-hydroxybutyrate-co-3-hydroxyvalerate)Poly(ε-caprolactone) 4-mm-diameter vascular grafts equipped with vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and stromal cell-derived factor 1α (SDF-1α) and surface coated with heparin and iloprost (PHBV/PCL[VEGF-bFGF-SDF], = 8) in a sheep carotid artery interposition model, using biostable vascular prostheses of expanded poly(tetrafluoroethylene) (ePTFE, = 5) as a control. Primary patency of PHBV/PCL[VEGF-bFGF-SDF] grafts was 62.

View Article and Find Full Text PDF

Modification by Arg-Gly-Asp (RGD) peptides is a promising approach to improve the biocompatibility of biodegradable vascular patches for arteriotomy. In this study, we evaluated the performance of vascular patches electrospun using a blend of polycaprolactone (PCL) and polyhydroxybutyrate/valerate (PHBV) and additionally modified with RGDK, AhRGD, and c[RGDFK] peptides using 1,6-hexamethylenediamine or 4,7,10-trioxa-1,13-tridecanediamine (TTDDA) linkers. We examined mechanical properties and hemocompatibility of resulting patches before implanting them in rat abdominal aortas to assess their performance in vivo.

View Article and Find Full Text PDF

The development of novel biodegradable vascular grafts of a small diameter (<6 mm) is an unmet clinical need for patients requiring arterial replacement. Here we performed a pre-clinical study of new small-caliber biodegradable vascular grafts using a sheep model of carotid artery implantation. The 4 mm diameter vascular grafts were manufactured using a mix of polyhydroxybutyrate/valerate and polycaprolactone supplemented with growth factors VEGF, bFGF and SDF-1α (PHBV/PCL-GFmix) and additionally modified by a polymer hydrogel coating with incorporation of drugs heparin and iloprost (PHBV/PCL-GFmix).

View Article and Find Full Text PDF

Polymeric heart valves seem to be an attractive alternative to mechanical and biological prostheses as they are more durable, due to the superior properties of novel polymers, and have the biocompatibility and hemodynamics comparable to tissue substitutes. This study reports a comprehensive assessment of a nanocomposite based on the functionalised graphene oxide and poly(carbonate-urea)urethane with the trade name "Hastalex" in comparison with GORE-TEX, a commercial polymer routinely used for cardiovascular medical devices. Experimental data have proved that GORE-TEX has a 2.

View Article and Find Full Text PDF
Article Synopsis
  • * In vitro tests showed that all modified grafts had reduced tensile strength, while RGD modifications did not cause hemolysis but increased platelet aggregation compared to unmodified grafts.
  • * The in vivo results indicated that using a specific cyclic RGD peptide enhanced graft biocompatibility, leading to recommendations for this modification approach in tissue engineering applications.
View Article and Find Full Text PDF

Background: Two-stage surgery including right ventricular outflow tract (RVOT) stenting with subsequent total surgical repair (TSG) has been suggested as a promising curative option in infants with tetralogy of Fallot (ToF) having comorbidities such as low body weight. However, data on clinical outcomes of such approach and tissue response to RVOT stenting in underweight infants are scarce.

Methods: We recruited 16 underweight (<3 kg; average weight, 2.

View Article and Find Full Text PDF

Infective endocarditis (IE) is a septic inflammation of the endocardium. Recognition of microbial patterns, cytokine and acute phase responses, hemostasis features, and alterations in plasma lipid and calcium profile all have been reported to affect pathogenesis and clinical course of IE. Having recruited 123 patients with IE and 300 age-, sex-, and ethnicity-matched healthy blood donors, we profiled their genomic DNA for 35 functionally significant polymorphisms within the 22 selected genes involved in the abovementioned pathways, with the further genetic association analysis.

View Article and Find Full Text PDF

The blend of poly(3-hydroxybutyrate--3-hydroxyvalerate) (PHBV) and poly(ε-caprolactone) (PCL) has recently been considered promising for vascular tissue engineering. However, it was shown that PHBV/PCL grafts require biofunctionalization to achieve high primary patency rate. Here we compared immobilization of arginine-glycine-aspartic acid (RGD)-containing peptides and the incorporation of vascular endothelial growth factor (VEGF) as two widely established biofunctionalization approaches.

View Article and Find Full Text PDF

Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification.

View Article and Find Full Text PDF

The combination of a natural polymer poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and a synthetic hydrophobic polymer poly(ε-caprolactone) (PCL) is promising for the preparation of biodegradable and biocompatible small-diameter vascular grafts for bypass surgery. However, physico-mechanical properties and endothelialization rate of PHBV/PCL grafts are poor. We suggested that incorporation of vascular endothelial growth factor (VEGF) into PHBV/PCL grafts may improve their physico-mechanical properties and enhance endothelialization.

View Article and Find Full Text PDF

Small diameter arterial bypass grafts are considered as unmet clinical need since the current grafts have poor patency of 25% within 5 years. We have developed a 3D scaffold manufactured from natural and synthetic biodegradable polymers, poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and poly(𝜀-caprolactone) (PCL), respectively. Further to improve the biophysical properties as well as endothelialisation, the grafts were covalently conjugated with arginine-glycine-aspartic acid (RGD) bioactive peptides.

View Article and Find Full Text PDF

Local vascular immune response is primarily initiated via Toll-like receptors (TLRs) and triggering receptor expressed on myeloid cells-1 (TREM-1). We previously showed that certain TLR and TREM-1 gene polymorphisms are associated with coronary artery disease (CAD). Therefore, we hypothesized that these gene polymorphisms are associated with atherosclerosis severity.

View Article and Find Full Text PDF

Objectives: The study aimed to evaluate whether serum inflammatory markers have prognostic value in patients with ST-segment elevation myocardial infarction (STEMI).

Background: The role of cytokine-driven inflammation in the development of postdischarge complications after STEMI is obscured.

Methods: We recruited 214 patients who were admitted within 24 h of STEMI onset to our Institute.

View Article and Find Full Text PDF

Background: This investigation was aimed at assessing the clinical significance of microalbuminuria (MA) in predicting in-hospital adverse outcomes amongst the patients with coronary artery disease (CAD) and type 2 diabetes mellitus (DM) who have undergone coronary artery bypass graft (CABG) surgery.

Methods: We recruited 720 consecutive Caucasian (Russian) patients who underwent CABG surgery during 2011-2012.

Results: Patients with renal dysfunction (RD) and without type 2 DM had significantly higher median serum creatinine seven days after CABG surgery compared to patients without RD and type 2 DM.

View Article and Find Full Text PDF

Infective endocarditis (IE) is an inflammatory condition of the lining of the heart chambers and valves, which is generally caused by bacteria. Toll-like receptors (TLRs) and Triggering receptor expressed on myeloid cells (TREMs) are key effectors of the innate system that play a significant role in the recognition of infectious agents, particularly, bacteria. We hypothesised that inherited variation in TLR and TREM-1 genes may affect individual susceptibility to IE.

View Article and Find Full Text PDF

Background: This study has been aimed to assess clinical significance of cystatin C in the prognosis of a risk of hospital complications among the patients with coronary artery disease CAD who have undergone coronary artery bypass surgery (CABG).

Methods: We have recruited 719 consecutive Caucasian (Russian) patients who underwent CABG in 2011-2012.

Results: No statistically significant differences in the serum creatinine concentration (sCr) and glomerular filtration rate before and seven days after the surgery have been found among the patients belonging to different EuroSCORE risk groups.

View Article and Find Full Text PDF
Article Synopsis
  • * In a study involving 702 patients with coronary artery disease (CAD) and 300 healthy controls, specific gene polymorphisms were found to affect CAD risk: the C/C genotype of TLR1 was linked to a reduced risk, while multiple TREM-1 variants were associated with increased risk.
  • * The findings suggest that genetic variations in TLR and TREM-1 may play significant roles in CAD among the Russian population, although their predictive value needs further exploration.
View Article and Find Full Text PDF

Hypothesis: To evaluate the clinical and prognostic role of haemodynamically insignificant stenosis of the extracranial arteries (ECA) and lower extremity arteries (LEA) among patients with ST-segment elevation myocardial infarction (STEMI).

Patients And Methods: The study sample consisted of 423 patients with STEMI who were consecutively admitted to the Kemerovo Cardiological Centre.

Results: The prevalence of polyvascular diseases (PVD), as defined by an increased intima-media thickness (IMT) of the common carotid artery or by stenosis of the ECA or LEA, was 95%.

View Article and Find Full Text PDF

Background: The severity of angiographically assessed coronary artery disease may be the factor that influences the degree of brain damage during on-pump surgery. Modern technology such as computed electroencephalography (EEG) that is used to detect signs of brain damage could also be used to determine the advantages and disadvantages of various surgical myocardial revascularization methods in certain categories of patients. The present study investigated EEG power dynamics for 1 postoperative month in patients undergoing on-pump coronary artery bypass grafting (CABG) who were divided into two groups: those with moderate coronary lesions (SYNTAX score ≤ 22, n = 12) and those with severe coronary lesions (SYNTAX score ≥ 23, n = 18).

View Article and Find Full Text PDF